Version: V3.0Release Date: 2026-08-10


R130C
Vendor ID 451 (0x01c3) Vendor Logo
Vendor Name Banner Engineering Corporation
Vendor Text More Sensors. More Solutions.
Vendor URL www.bannerengineering.com/io-link
Device ID 659487 (0x0a101f)
DeviceFamily R130C Series
Features
Block Parameter yes
Data Storage yes
Profile Characteristic 0x4000 (Common Application Profile: Identification and Diagnosis), 0x8101 (Function Class: Locator)
Supported Access Locks Parameter: no, Data Storage: no, Local Parameterization: yes, Local User Interface: yes
Communication
IO-Link Revision V1.1
Transmission Rate38400 bit/s (COM2)
Minimum Cycle Time 13.6 ms
SIO Mode Supported yes
M-Sequence CapabilityPREOPERATE = TYPE_1_V with 8 octets on-request data
OPERATE = TYPE_2_V with 2 octets on-request data
ISDU supported
Device Variant R130C-8UI-KQ
Description 8 Channel Analog to IO-Link converter
Product ID R130C-8UI-KQ
Device Icon Device Icon
Device Symbol Device Symbol
Connection TypeM12-4 connector
- pin 1 brown; L+
- pin 2 white; Other
- pin 3 (light) blue; L-
- pin 4 black; C/Q

ProcessData id=P_ProcessDataWithSignal (condition V_Vendor_Specific_Configuration.Process Data Input Configuration = 0)

ProcessDataIn "Analog Process Data Input" id=PI_ProcessDataInAnalog

bit length: 256
data type: 256-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 224 32-bit Integer Measurement Value 1 The channel 1 measurement device value
5 192 32-bit Integer Measurement Value 2 The channel 2 measurement device value
9 160 32-bit Integer Measurement Value 3 The channel 3 measurement device value
13 128 32-bit Integer Measurement Value 4 The channel 4 measurement device value
17 96 32-bit Integer Measurement Value 5 The channel 5 measurement device value
21 64 32-bit Integer Measurement Value 6 The channel 6 measurement device value
25 32 32-bit Integer Measurement Value 7 The channel 7 measurement device value
29 0 32-bit Integer Measurement Value 8 The channel 8 measurement device value

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192
subindex 1 1 1 1 5 5 5 5
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 9 9 9 9 13 13 13 13
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 17 17 17 17 21 21 21 21
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 25 25 25 25 29 29 29 29
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

ProcessData id=P_ProcessDataWithDMS (condition V_Vendor_Specific_Configuration.Process Data Input Configuration = 1)

ProcessDataIn "Digital Measuring Sensor Process Data Input" id=PI_ProcessDataInDMS

bit length: 256
data type: 256-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 240 16-bit Integer Measurement Value 1 The channel 1 measurement device value
2 232 8-bit Integer Measurement Scale 1 The channel 1 measurement device scale
4 224 Boolean SSC1.1 - Switching Signal Indicates the detection status of an object or measurement value within a window.
5 208 16-bit Integer Measurement Value 2 The channel 2 measurement device value
6 200 8-bit Integer Measurement Scale 2 The channel 2 measurement device scale
8 192 Boolean SSC2.1 - Switching Signal Indicates the detection status of an object or measurement value within a window.
9 176 16-bit Integer Measurement Value 3 The channel 3 measurement device value
10 168 8-bit Integer Measurement Scale 3 The channel 3 measurement device scale
12 160 Boolean SSC3.1 - Switching Signal Indicates the detection status of an object or measurement value within a window.
13 144 16-bit Integer Measurement Value 4 The channel 4 measurement device value
14 136 8-bit Integer Measurement Scale 4 The channel 4 measurement device scale
16 128 Boolean SSC4.1 - Switching Signal Indicates the detection status of an object or measurement value within a window.
17 112 16-bit Integer Measurement Value 5 The channel 5 measurement device value
18 104 8-bit Integer Measurement Scale 5 The channel 5 measurement device scale
20 96 Boolean SSC5.1 - Switching Signal Indicates the detection status of an object or measurement value within a window.
21 80 16-bit Integer Measurement Value 6 The channel 6 measurement device value
22 72 8-bit Integer Measurement Scale 6 The channel 6 measurement device scale
24 64 Boolean SSC6.1 - Switching Signal Indicates the detection status of an object or measurement value within a window.
25 48 16-bit Integer Measurement Value 7 The channel 7 measurement device value
26 40 8-bit Integer Measurement Scale 7 The channel 7 measurement device scale
28 32 Boolean SSC7.1 - Switching Signal Indicates the detection status of an object or measurement value within a window.
29 16 16-bit Integer Measurement Value 8 The channel 8 measurement device value
30 8 8-bit Integer Measurement Scale 8 The channel 8 measurement device scale
32 0 Boolean SSC8.1 - Switching Signal Indicates the detection status of an object or measurement value within a window.
Octet 0
bit offset 255 254 253 252 251 250 249 248
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 247 246 245 244 243 242 241 240
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 239 238 237 236 235 234 233 232
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 231 230 229 228 227 226 225 224
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 4
Octet 4
bit offset 223 222 221 220 219 218 217 216
subindex 5
element bit 15 14 13 12 11 10 9 8
Octet 5
bit offset 215 214 213 212 211 210 209 208
subindex 5
element bit 7 6 5 4 3 2 1 0
Octet 6
bit offset 207 206 205 204 203 202 201 200
subindex 6
element bit 7 6 5 4 3 2 1 0
Octet 7
bit offset 199 198 197 196 195 194 193 192
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 8
Octet 8
bit offset 191 190 189 188 187 186 185 184
subindex 9
element bit 15 14 13 12 11 10 9 8
Octet 9
bit offset 183 182 181 180 179 178 177 176
subindex 9
element bit 7 6 5 4 3 2 1 0
Octet 10
bit offset 175 174 173 172 171 170 169 168
subindex 10
element bit 7 6 5 4 3 2 1 0
Octet 11
bit offset 167 166 165 164 163 162 161 160
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 12
Octet 12
bit offset 159 158 157 156 155 154 153 152
subindex 13
element bit 15 14 13 12 11 10 9 8
Octet 13
bit offset 151 150 149 148 147 146 145 144
subindex 13
element bit 7 6 5 4 3 2 1 0
Octet 14
bit offset 143 142 141 140 139 138 137 136
subindex 14
element bit 7 6 5 4 3 2 1 0
Octet 15
bit offset 135 134 133 132 131 130 129 128
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 16
Octet 16
bit offset 127 126 125 124 123 122 121 120
subindex 17
element bit 15 14 13 12 11 10 9 8
Octet 17
bit offset 119 118 117 116 115 114 113 112
subindex 17
element bit 7 6 5 4 3 2 1 0
Octet 18
bit offset 111 110 109 108 107 106 105 104
subindex 18
element bit 7 6 5 4 3 2 1 0
Octet 19
bit offset 103 102 101 100 99 98 97 96
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 20
Octet 20
bit offset 95 94 93 92 91 90 89 88
subindex 21
element bit 15 14 13 12 11 10 9 8
Octet 21
bit offset 87 86 85 84 83 82 81 80
subindex 21
element bit 7 6 5 4 3 2 1 0
Octet 22
bit offset 79 78 77 76 75 74 73 72
subindex 22
element bit 7 6 5 4 3 2 1 0
Octet 23
bit offset 71 70 69 68 67 66 65 64
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 24
Octet 24
bit offset 63 62 61 60 59 58 57 56
subindex 25
element bit 15 14 13 12 11 10 9 8
Octet 25
bit offset 55 54 53 52 51 50 49 48
subindex 25
element bit 7 6 5 4 3 2 1 0
Octet 26
bit offset 47 46 45 44 43 42 41 40
subindex 26
element bit 7 6 5 4 3 2 1 0
Octet 27
bit offset 39 38 37 36 35 34 33 32
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 28
Octet 28
bit offset 31 30 29 28 27 26 25 24
subindex 29
element bit 15 14 13 12 11 10 9 8
Octet 29
bit offset 23 22 21 20 19 18 17 16
subindex 29
element bit 7 6 5 4 3 2 1 0
Octet 30
bit offset 15 14 13 12 11 10 9 8
subindex 30
element bit 7 6 5 4 3 2 1 0
Octet 31
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 32

Standard Variable "Direct Parameters - Page 1" index=0 id=V_DirectParameters_1

description: Comprises the required parameters defining the communication characteristics and identifiers for device validation.
data type: 128-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger ro Reserved
2 112 8-bit UInteger ro Master Cycle Time Communication: Current communication cycle duration used by the master. This value defines the process data cycle.
3 104 8-bit UInteger ro Min Cycle Time Communication: Minimum communication cycle duration supported by the device. This value defines the lowest possible process data cycle.
4 96 8-bit UInteger ro M-Sequence Capability Communication: Information on the structure and the supported features of the communication messages.
5 88 8-bit UInteger 17 ro IO-Link Revision ID Communication: Identifier for the currently used communication protocol revision.
6 80 8-bit UInteger ro Process Data Input Length Communication: Information on width and features of the process input data (Process Data from Device to Master).
7 72 8-bit UInteger ro Process Data Output Length Communication: Information on width of the process output data (Process Data from Master to Device).
8 64 8-bit UInteger ro Vendor ID 1 Identification: Highest octet of the Vendor ID. Combined with the parameter Vendor ID 2, this parameter defines the 16-bit value of the unique Vendor ID as assigned by the IO-Link Community.
9 56 8-bit UInteger ro Vendor ID 2 Identification: Lowest octet of the Vendor ID. Combined with the parameter Vendor ID 1, this parameter defines the 16-bit value of the unique Vendor ID as assigned by the IO-Link Community.
10 48 8-bit UInteger ro Device ID 1 Identification: Highest octet of the Device ID. Combined with the parameters Device ID 2 and 3, this parameter defines the 24-bit value of the vendor-specific Device ID.
11 40 8-bit UInteger ro Device ID 2 Identification: Middle octet of the Device ID. Combined with the parameters Device ID 1 and 3, this parameter defines the 24-bit value of the vendor-specific Device ID.
12 32 8-bit UInteger ro Device ID 3 Identification: Lowest octet of the Device ID. Combined with the parameters Device ID 1 and 2, this parameter defines the 24-bit value of the vendor-specific Device ID.
13 24 8-bit UInteger ro Reserved
14 16 8-bit UInteger ro Reserved
15 8 8-bit UInteger ro Reserved
16 0 8-bit UInteger wo X System Command Application: Command interface for devices without ISDU support. Validity and execution of commands are not confirmed.

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "System Command" index=2 id=V_SystemCommand

description: Command interface for applications. A positive acknowledge indicates the complete and correct finalization of the requested function.
data type: 8-bit UInteger
allowed values: 126 = Locator Start, 127 = Locator Stop, 129 = Application Reset, 131 = Back-to-box
access rights: wo
modifies other variables

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Device Access Locks" index=12 id=V_DeviceAccessLocks

description: The access to the device parameters can be restricted by setting appropriate flags within this parameter.
data type: 16-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = Unlocked, true = Locked Parameter Write Access This lock prevents the write access to all read/write parameters of the device except for the parameter 'Device Access Locks'.
2 1 Boolean false = Unlocked, true = Locked Data Storage This lock prevents the write access to the device parameters via the data storage mechanism.
3 2 Boolean false = Unlocked, true = Locked Local Parameterization This lock prevents the device settings from being changed via local operating elements on the device.
4 3 Boolean false = Unlocked, true = Locked Local User Interface This lock prevents the access to the device settings and display via a local user interface. The user interface is disabled.
Octet 0
bit offset 15 14 13 12 11 10 9 8
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 1
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4 3 2 1

Standard Variable "Vendor Name" index=16 id=V_VendorName

description: The vendor name that is assigned to a Vendor ID.
data type: 64-octet String UTF-8
default value: "Banner Engineering Corporation"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Vendor Text" index=17 id=V_VendorText

description: Additional information about the vendor.
data type: 64-octet String UTF-8
default value: "More Sensors. More Solutions."
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product Name" index=18 id=V_ProductName

description: Complete product name.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product ID" index=19 id=V_ProductID

description: Vendor-specific product or type identification (e.g., item number or model number).
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product Text" index=20 id=V_ProductText

description: Additional product information for the device.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Serial Number" index=21 id=V_SerialNumber

description: Unique, vendor-specific identifier of the individual device.
data type: 16-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Hardware Revision" index=22 id=V_HardwareRevision

description: Unique, vendor-specific identifier of the hardware revision of the individual device.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Firmware Revision" index=23 id=V_FirmwareRevision

description: Unique, vendor-specific identifier of the firmware revision of the individual device.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Application-specific Tag" index=24 id=V_ApplicationSpecificTag

description: Possibility to mark a device with user- or application-specific information.
data type: 32-octet String UTF-8
default value: "More Sensors. More Solutions."
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Device Status" index=36 id=V_DeviceStatus

description: Indicator for the current device condition and diagnosis state.
data type: 8-bit UInteger
allowed values: 0 = Device is OK, 1 = Maintenance required, 2 = Out of specification, 3 = Functional check, 4 = Failure
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Detailed Device Status" index=37 id=V_DetailedDeviceStatus

description: List of all currently pending events in the device.
data type: Array[6] of 3-octet OctetString (subindex access not supported)
access rights: ro
dynamic

octet 0 1 2 3 4 5 6 7
bit offset 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80
subindex 1 1 1 2 2 2 3 3

octet 8 9 10 11 12 13 14 15
bit offset 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16
subindex 3 4 4 4 5 5 5 6

octet 16 17  
bit offset 15 - 8 7 - 0  
subindex 6 6  

Standard Variable "PD Input" index=40 id=V_ProcessDataInput

description: Last valid process input data of the device.
data type: see ProcessDataIn!
access rights: ro
dynamic

Variable "Function Tag" index=25 id=V_CP_FunctionTag

description: Possibility to mark a device with function-specific information.
data type: 32-octet String UTF-8
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Location Tag" index=26 id=V_CP_LocationTag

description: Possibility to mark a device with location-specific information.
data type: 32-octet String UTF-8
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "All-time Run Time" index=69 id=V_AllTimeRunTime

description: A read only run time counter (in hours) that tracks the total time the sensor has been running since manufacture
data type: 32-bit Record (subindex access not supported)
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0..2147483647 Run counter Run counter

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Resetable Run Time" index=70 id=V_ResetableRunTime

description: A read / write run time counter (in hours) that can be monitored or set by the user
data type: 32-bit Record (subindex access not supported)
access rights: rw
excluded from data storage

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0..2147483647 Run counter Run counter

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Pulse Frequency Configuration" index=71 id=V_PulseFrequencyConfiguration

description: Configuration of pulse frequency ranges.
data type: 64-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 100..45000 100 Near Frequency The frequency corresponding to a target at the near limit of the sensing range.
2 32 32-bit Integer 100..45000 600 Far Frequency The frequency corresponding to a target at the far limit of the sensing range.

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 2 2 2 2 1 1 1 1
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Pulse Frequency LOS Frequency" index=72 id=V_PulseFrequencyLOSFrequency

description: Frequency used to indicate Loss-of-Signal
data type: 32-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 50..45000 50 Pulse Frequency LOS Frequency Frequency used to indicate Loss-of-Signal

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Vendor Specific Configuration" index=76 id=V_Vendor_Specific_Configuration

description: Vendor Specific Configuration
data type: 104-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = Analog Value, 1 = Digital Measuring Sensor 0 Process Data Input Configuration The available Process Data Input Data Map Selections
2 8 16-bit UInteger 200 IOL Filter Time Time to average IOL process data measurement between updates.
3 24 8-bit UInteger 0 = Disabled, 1 = Pulse Frequency Modulation 0 Secondary Output Function The function of the secondary output channel
4 32 8-bit UInteger 0 = Analog In 1, 1 = Analog In 2, 2 = Analog In 3, 3 = Analog In 4, 4 = Analog In 5, 5 = Analog In 6, 6 = Analog In 7, 7 = Analog In 8 0 PFM Input Port Selection Analog input channel to use to determine PFM output frequency.
5 40 8-bit UInteger 0 = Voltage, 1 = Current 1 Analog In 1 Mode The Mode of Analog In 1 (Voltage or Current)
6 48 8-bit UInteger 0 = Voltage, 1 = Current 1 Analog In 2 Mode The Mode of Analog In 2 (Voltage or Current)
7 56 8-bit UInteger 0 = Voltage, 1 = Current 1 Analog In 3 Mode The Mode of Analog In 3 (Voltage or Current)
8 64 8-bit UInteger 0 = Voltage, 1 = Current 1 Analog In 4 Mode The Mode of Analog In 4 (Voltage or Current)
9 72 8-bit UInteger 0 = Voltage, 1 = Current 1 Analog In 5 Mode The Mode of Analog In 5 (Voltage or Current)
10 80 8-bit UInteger 0 = Voltage, 1 = Current 1 Analog In 6 Mode The Mode of Analog In 6 (Voltage or Current)
11 88 8-bit UInteger 0 = Voltage, 1 = Current 1 Analog In 7 Mode The Mode of Analog In 7 (Voltage or Current)
12 96 8-bit UInteger 0 = Voltage, 1 = Current 1 Analog In 8 Mode The Mode of Analog In 8 (Voltage or Current)

octet 0 1 2 3 4 5 6 7
bit offset 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40
subindex 12 11 10 9 8 7 6 5
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12  
bit offset 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 4 3 2 2 1  
element bit 7 - 0 7 - 0 15 - 8 7 - 0 7 - 0  

Variable "All-time Run Time Event Time" index=78 id=V_AllTimeRunTimeEventTime

description: Running time when an event will be raised indicating that service is required. Set to 0 to disable raising event.
data type: 32-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0..2147483647 0 Event Time Event indicating the corresponding configured running time has elapsed.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Resetable Run Time Event Time" index=79 id=V_ResetableRunTimeEventTime

description: Running time when an event will be raised indicating that service is required. Set to 0 to disable raising event.
data type: 32-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0..2147483647 0 Event Time Running time when an event will be raised indicating that service is required. Set to 0 to disable raising event.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "MDC Descriptor 1" index=12544 id=V_MDCDescriptor

description: Measuring Data Channel Descriptor - refer to Smart Sensor Profile 2nd Ed.
data type: 88-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer MDC Descr - Lower Limit
2 24 32-bit Integer MDC Descr - Upper Limit
3 8 16-bit UInteger 1209 = A, 1240 = V MDC Descr - Unit
4 0 8-bit Integer MDC Descr - Scale

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Variable "MDC Descriptor 2" index=12545 id=V_MDCDescriptor_2

description: Measuring Data Channel Descriptor - refer to Smart Sensor Profile 2nd Ed.
data type: 88-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer MDC Descr - Lower Limit
2 24 32-bit Integer MDC Descr - Upper Limit
3 8 16-bit UInteger 1209 = A, 1240 = V MDC Descr - Unit
4 0 8-bit Integer MDC Descr - Scale

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Variable "MDC Descriptor 3" index=12546 id=V_MDCDescriptor_3

description: Measuring Data Channel Descriptor - refer to Smart Sensor Profile 2nd Ed.
data type: 88-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer MDC Descr - Lower Limit
2 24 32-bit Integer MDC Descr - Upper Limit
3 8 16-bit UInteger 1209 = A, 1240 = V MDC Descr - Unit
4 0 8-bit Integer MDC Descr - Scale

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Variable "MDC Descriptor 4" index=12547 id=V_MDCDescriptor_4

description: Measuring Data Channel Descriptor - refer to Smart Sensor Profile 2nd Ed.
data type: 88-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer MDC Descr - Lower Limit
2 24 32-bit Integer MDC Descr - Upper Limit
3 8 16-bit UInteger 1209 = A, 1240 = V MDC Descr - Unit
4 0 8-bit Integer MDC Descr - Scale

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Variable "MDC Descriptor 5" index=12548 id=V_MDCDescriptor_5

description: Measuring Data Channel Descriptor - refer to Smart Sensor Profile 2nd Ed.
data type: 88-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer MDC Descr - Lower Limit
2 24 32-bit Integer MDC Descr - Upper Limit
3 8 16-bit UInteger 1209 = A, 1240 = V MDC Descr - Unit
4 0 8-bit Integer MDC Descr - Scale

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Variable "MDC Descriptor 6" index=12549 id=V_MDCDescriptor_6

description: Measuring Data Channel Descriptor - refer to Smart Sensor Profile 2nd Ed.
data type: 88-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer MDC Descr - Lower Limit
2 24 32-bit Integer MDC Descr - Upper Limit
3 8 16-bit UInteger 1209 = A, 1240 = V MDC Descr - Unit
4 0 8-bit Integer MDC Descr - Scale

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Variable "MDC Descriptor 7" index=12550 id=V_MDCDescriptor_7

description: Measuring Data Channel Descriptor - refer to Smart Sensor Profile 2nd Ed.
data type: 88-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer MDC Descr - Lower Limit
2 24 32-bit Integer MDC Descr - Upper Limit
3 8 16-bit UInteger 1209 = A, 1240 = V MDC Descr - Unit
4 0 8-bit Integer MDC Descr - Scale

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Variable "MDC Descriptor 8" index=12551 id=V_MDCDescriptor_8

description: Measuring Data Channel Descriptor - refer to Smart Sensor Profile 2nd Ed.
data type: 88-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer MDC Descr - Lower Limit
2 24 32-bit Integer MDC Descr - Upper Limit
3 8 16-bit UInteger 1209 = A, 1240 = V MDC Descr - Unit
4 0 8-bit Integer MDC Descr - Scale

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Variable "Channel 1 Setpoints" index=12560 id=V_BDC1_Setpoints

description: The reference value used for sensor switching
data type: 192-bit Record (subindex access not supported)
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0 Voltage SP1 Voltage SP1 switch point.
2 32 32-bit Integer 10000 Voltage SP2 Voltage SP2 switch point.
3 64 32-bit Integer 50 Voltage Hysteresis The hysteresis value for the Voltage switchpoint.
4 96 32-bit Integer 4000 Current SP1 Current SP1 switch point.
5 128 32-bit Integer 20000 Current SP2 Current SP2 switch point.
6 160 32-bit Integer 100 Current Hysteresis The hysteresis value for the Current switchpoint.

octet 0 1 2 3 4 5 6 7
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 6 6 6 6 5 5 5 5
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 4 4 4 4 3 3 3 3
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 2 2 2 2 1 1 1 1
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Channel 2 Setpoints" index=12561 id=V_SSC2_BDC1_Setpoints

description: The reference value used for sensor switching
data type: 192-bit Record (subindex access not supported)
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0 Voltage SP1 Voltage SP1 switch point.
2 32 32-bit Integer 10000 Voltage SP2 Voltage SP2 switch point.
3 64 32-bit Integer 50 Voltage Hysteresis The hysteresis value for the Voltage switchpoint.
4 96 32-bit Integer 4000 Current SP1 Current SP1 switch point.
5 128 32-bit Integer 20000 Current SP2 Current SP2 switch point.
6 160 32-bit Integer 100 Current Hysteresis The hysteresis value for the Current switchpoint.

octet 0 1 2 3 4 5 6 7
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 6 6 6 6 5 5 5 5
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 4 4 4 4 3 3 3 3
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 2 2 2 2 1 1 1 1
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Channel 3 Setpoints" index=12562 id=V_SSC3_BDC1_Setpoints

description: The reference value used for sensor switching
data type: 192-bit Record (subindex access not supported)
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0 Voltage SP1 Voltage SP1 switch point.
2 32 32-bit Integer 10000 Voltage SP2 Voltage SP2 switch point.
3 64 32-bit Integer 50 Voltage Hysteresis The hysteresis value for the Voltage switchpoint.
4 96 32-bit Integer 4000 Current SP1 Current SP1 switch point.
5 128 32-bit Integer 20000 Current SP2 Current SP2 switch point.
6 160 32-bit Integer 100 Current Hysteresis The hysteresis value for the Current switchpoint.

octet 0 1 2 3 4 5 6 7
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 6 6 6 6 5 5 5 5
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 4 4 4 4 3 3 3 3
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 2 2 2 2 1 1 1 1
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Channel 4 Setpoints" index=12563 id=V_SSC4_BDC1_Setpoints

description: The reference value used for sensor switching
data type: 192-bit Record (subindex access not supported)
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0 Voltage SP1 Voltage SP1 switch point.
2 32 32-bit Integer 10000 Voltage SP2 Voltage SP2 switch point.
3 64 32-bit Integer 50 Voltage Hysteresis The hysteresis value for the Voltage switchpoint.
4 96 32-bit Integer 4000 Current SP1 Current SP1 switch point.
5 128 32-bit Integer 20000 Current SP2 Current SP2 switch point.
6 160 32-bit Integer 100 Current Hysteresis The hysteresis value for the Current switchpoint.

octet 0 1 2 3 4 5 6 7
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 6 6 6 6 5 5 5 5
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 4 4 4 4 3 3 3 3
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 2 2 2 2 1 1 1 1
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Channel 5 Setpoints" index=12564 id=V_SSC5_BDC1_Setpoints

description: The reference value used for sensor switching
data type: 192-bit Record (subindex access not supported)
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0 Voltage SP1 Voltage SP1 switch point.
2 32 32-bit Integer 10000 Voltage SP2 Voltage SP2 switch point.
3 64 32-bit Integer 50 Voltage Hysteresis The hysteresis value for the Voltage switchpoint.
4 96 32-bit Integer 4000 Current SP1 Current SP1 switch point.
5 128 32-bit Integer 20000 Current SP2 Current SP2 switch point.
6 160 32-bit Integer 100 Current Hysteresis The hysteresis value for the Current switchpoint.

octet 0 1 2 3 4 5 6 7
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 6 6 6 6 5 5 5 5
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 4 4 4 4 3 3 3 3
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 2 2 2 2 1 1 1 1
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Channel 6 Setpoints" index=12565 id=V_SSC6_BDC1_Setpoints

description: The reference value used for sensor switching
data type: 192-bit Record (subindex access not supported)
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0 Voltage SP1 Voltage SP1 switch point.
2 32 32-bit Integer 10000 Voltage SP2 Voltage SP2 switch point.
3 64 32-bit Integer 50 Voltage Hysteresis The hysteresis value for the Voltage switchpoint.
4 96 32-bit Integer 4000 Current SP1 Current SP1 switch point.
5 128 32-bit Integer 20000 Current SP2 Current SP2 switch point.
6 160 32-bit Integer 100 Current Hysteresis The hysteresis value for the Current switchpoint.

octet 0 1 2 3 4 5 6 7
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 6 6 6 6 5 5 5 5
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 4 4 4 4 3 3 3 3
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 2 2 2 2 1 1 1 1
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Channel 7 Setpoints" index=12566 id=V_SSC7_BDC1_Setpoints

description: The reference value used for sensor switching
data type: 192-bit Record (subindex access not supported)
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0 Voltage SP1 Voltage SP1 switch point.
2 32 32-bit Integer 10000 Voltage SP2 Voltage SP2 switch point.
3 64 32-bit Integer 50 Voltage Hysteresis The hysteresis value for the Voltage switchpoint.
4 96 32-bit Integer 4000 Current SP1 Current SP1 switch point.
5 128 32-bit Integer 20000 Current SP2 Current SP2 switch point.
6 160 32-bit Integer 100 Current Hysteresis The hysteresis value for the Current switchpoint.

octet 0 1 2 3 4 5 6 7
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 6 6 6 6 5 5 5 5
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 4 4 4 4 3 3 3 3
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 2 2 2 2 1 1 1 1
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Channel 8 Setpoints" index=12567 id=V_SSC8_BDC1_Setpoints

description: The reference value used for sensor switching
data type: 192-bit Record (subindex access not supported)
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0 Voltage SP1 Voltage SP1 switch point.
2 32 32-bit Integer 10000 Voltage SP2 Voltage SP2 switch point.
3 64 32-bit Integer 50 Voltage Hysteresis The hysteresis value for the Voltage switchpoint.
4 96 32-bit Integer 4000 Current SP1 Current SP1 switch point.
5 128 32-bit Integer 20000 Current SP2 Current SP2 switch point.
6 160 32-bit Integer 100 Current Hysteresis The hysteresis value for the Current switchpoint.

octet 0 1 2 3 4 5 6 7
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 6 6 6 6 5 5 5 5
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 4 4 4 4 3 3 3 3
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 2 2 2 2 1 1 1 1
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Events

CodeTypeNameDescription
25376 (0x6320)ErrorParameter errorCheck datasheet and values
36000 (0x8ca0)WarningAll-time Run Time EventEvent indicating the corresponding configured running time has elapsed.
36001 (0x8ca1)WarningResetable Run Time EventEvent indicating the corresponding configured running time has elapsed.

Process Data Formatting

Formatting for Process Data id=PI_ProcessDataInAnalog
Subindex 1:
Subindex 5:
Subindex 9:
Subindex 13:
Subindex 17:
Subindex 21:
Subindex 25:
Subindex 29:

Formatting for Process Data id=PI_ProcessDataInDMS
Subindex 1:
Subindex 2:
Subindex 4:
Subindex 5:
Subindex 6:
Subindex 8:
Subindex 9:
Subindex 10:
Subindex 12:
Subindex 13:
Subindex 14:
Subindex 16:
Subindex 17:
Subindex 18:
Subindex 20:
Subindex 21:
Subindex 22:
Subindex 24:
Subindex 25:
Subindex 26:
Subindex 28:
Subindex 29:
Subindex 30:
Subindex 32:

Operator Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag, ro
V_CP_FunctionTag, ro
V_CP_LocationTag, ro

Parameters Menu
V_Vendor_Specific_Configuration.Process Data Input Configuration, ro
V_Vendor_Specific_Configuration.Analog In 1 Mode, ro
V_Vendor_Specific_Configuration.Analog In 2 Mode, ro
V_Vendor_Specific_Configuration.Analog In 3 Mode, ro
V_Vendor_Specific_Configuration.Analog In 4 Mode, ro
V_Vendor_Specific_Configuration.Analog In 5 Mode, ro
V_Vendor_Specific_Configuration.Analog In 6 Mode, ro
V_Vendor_Specific_Configuration.Analog In 7 Mode, ro
V_Vendor_Specific_Configuration.Analog In 8 Mode, ro

Observation Menu
If V_Vendor_Specific_Configuration.Analog In 1 Mode = 0:
Process Data Input Channel 1
V_ProcessDataInput.1 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 1 Mode = 1:
Process Data Input Channel 1
V_ProcessDataInput.1 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 2 Mode = 0:
Process Data Input Channel 2
V_ProcessDataInput.5 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 2 Mode = 1:
Process Data Input Channel 2
V_ProcessDataInput.5 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 3 Mode = 0:
Process Data Input Channel 3
V_ProcessDataInput.9 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 3 Mode = 1:
Process Data Input Channel 3
V_ProcessDataInput.9 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 4 Mode = 0:
Process Data Input Channel 4
V_ProcessDataInput.13 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 4 Mode = 1:
Process Data Input Channel 4
V_ProcessDataInput.13 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 5 Mode = 0:
Process Data Input Channel 5
V_ProcessDataInput.17 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 5 Mode = 1:
Process Data Input Channel 5
V_ProcessDataInput.17 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 6 Mode = 0:
Process Data Input Channel 6
V_ProcessDataInput.21 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 6 Mode = 1:
Process Data Input Channel 6
V_ProcessDataInput.21 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 7 Mode = 0:
Process Data Input Channel 7
V_ProcessDataInput.25 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 7 Mode = 1:
Process Data Input Channel 7
V_ProcessDataInput.25 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 8 Mode = 0:
Process Data Input Channel 8
V_ProcessDataInput.29 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 8 Mode = 1:
Process Data Input Channel 8
V_ProcessDataInput.29 * 1E-06 A, Dec.6

Diagnosis Menu
Device Status Information
V_DeviceStatus
V_DetailedDeviceStatus
Service Functions
V_SystemCommand, Button:=126
Description=The visual indicators of the device are switched to the localization display pattern, which makes it easier to spot a device in an application.
V_SystemCommand, Button:=127
Description=The localization indication pattern is stopped. The optical indicators of the device will show again the device specific states of operation.

Maintenance Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag
V_CP_FunctionTag
V_CP_LocationTag

Parameters Menu
Service Functions
V_SystemCommand, Button:=129
Description=The parameters of the technology-specific application are set to default values. Identification parameters remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master.
V_SystemCommand, Button:=131
Description=The parameters of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port!
Access Locks
V_DeviceAccessLocks.Local Parameterization
V_DeviceAccessLocks.Local User Interface
Vendor Specific Configuration
V_Vendor_Specific_Configuration.Process Data Input Configuration
V_Vendor_Specific_Configuration.IOL Filter Time ms
V_Vendor_Specific_Configuration.Secondary Output Function
V_Vendor_Specific_Configuration.PFM Input Port Selection
V_Vendor_Specific_Configuration.Analog In 1 Mode
V_Vendor_Specific_Configuration.Analog In 2 Mode
V_Vendor_Specific_Configuration.Analog In 3 Mode
V_Vendor_Specific_Configuration.Analog In 4 Mode
V_Vendor_Specific_Configuration.Analog In 5 Mode
V_Vendor_Specific_Configuration.Analog In 6 Mode
V_Vendor_Specific_Configuration.Analog In 7 Mode
V_Vendor_Specific_Configuration.Analog In 8 Mode
Pulse Frequency Configuration
V_PulseFrequencyConfiguration.Near Frequency Hz
V_PulseFrequencyConfiguration.Far Frequency Hz
V_PulseFrequencyLOSFrequency.Pulse Frequency LOS Frequency Hz
Channel 1 Setpoints
V_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 2 Setpoints
V_SSC2_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC2_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC2_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC2_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC2_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC2_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 3 Setpoints
V_SSC3_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC3_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC3_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC3_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC3_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC3_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 4 Setpoints
V_SSC4_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC4_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC4_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC4_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC4_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC4_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 5 Setpoints
V_SSC5_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC5_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC5_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC5_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC5_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC5_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 6 Setpoints
V_SSC6_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC6_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC6_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC6_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC6_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC6_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 7 Setpoints
V_SSC7_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC7_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC7_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC7_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC7_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC7_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 8 Setpoints
V_SSC8_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC8_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC8_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC8_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC8_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC8_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6

Observation Menu
If V_Vendor_Specific_Configuration.Analog In 1 Mode = 0:
Process Data Input Channel 1
V_ProcessDataInput.1 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 1 Mode = 1:
Process Data Input Channel 1
V_ProcessDataInput.1 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 2 Mode = 0:
Process Data Input Channel 2
V_ProcessDataInput.5 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 2 Mode = 1:
Process Data Input Channel 2
V_ProcessDataInput.5 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 3 Mode = 0:
Process Data Input Channel 3
V_ProcessDataInput.9 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 3 Mode = 1:
Process Data Input Channel 3
V_ProcessDataInput.9 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 4 Mode = 0:
Process Data Input Channel 4
V_ProcessDataInput.13 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 4 Mode = 1:
Process Data Input Channel 4
V_ProcessDataInput.13 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 5 Mode = 0:
Process Data Input Channel 5
V_ProcessDataInput.17 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 5 Mode = 1:
Process Data Input Channel 5
V_ProcessDataInput.17 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 6 Mode = 0:
Process Data Input Channel 6
V_ProcessDataInput.21 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 6 Mode = 1:
Process Data Input Channel 6
V_ProcessDataInput.21 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 7 Mode = 0:
Process Data Input Channel 7
V_ProcessDataInput.25 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 7 Mode = 1:
Process Data Input Channel 7
V_ProcessDataInput.25 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 8 Mode = 0:
Process Data Input Channel 8
V_ProcessDataInput.29 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 8 Mode = 1:
Process Data Input Channel 8
V_ProcessDataInput.29 * 1E-06 A, Dec.6

Diagnosis Menu
Service Functions
V_SystemCommand, Button:=126
Description=The visual indicators of the device are switched to the localization display pattern, which makes it easier to spot a device in an application.
V_SystemCommand, Button:=127
Description=The localization indication pattern is stopped. The optical indicators of the device will show again the device specific states of operation.
Device Status Information
V_DeviceStatus
V_DetailedDeviceStatus
If V_Vendor_Specific_Configuration.Analog In 1 Mode = 0:
Measuring Data Channel 1
V_MDCDescriptor.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor.MDC Descr - Scale
V_MDCDescriptor.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 1 Mode = 1:
Measuring Data Channel 1
V_MDCDescriptor.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor.MDC Descr - Scale
V_MDCDescriptor.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 2 Mode = 0:
Measuring Data Channel 2
V_MDCDescriptor_2.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_2.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_2.MDC Descr - Scale
V_MDCDescriptor_2.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 2 Mode = 1:
Measuring Data Channel 2
V_MDCDescriptor_2.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_2.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_2.MDC Descr - Scale
V_MDCDescriptor_2.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 3 Mode = 0:
Measuring Data Channel 3
V_MDCDescriptor_3.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_3.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_3.MDC Descr - Scale
V_MDCDescriptor_3.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 3 Mode = 1:
Measuring Data Channel 3
V_MDCDescriptor_3.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_3.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_3.MDC Descr - Scale
V_MDCDescriptor_3.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 4 Mode = 0:
Measuring Data Channel 4
V_MDCDescriptor_4.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_4.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_4.MDC Descr - Scale
V_MDCDescriptor_4.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 4 Mode = 1:
Measuring Data Channel 4
V_MDCDescriptor_4.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_4.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_4.MDC Descr - Scale
V_MDCDescriptor_4.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 5 Mode = 0:
Measuring Data Channel 5
V_MDCDescriptor_5.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_5.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_5.MDC Descr - Scale
V_MDCDescriptor_5.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 5 Mode = 1:
Measuring Data Channel 5
V_MDCDescriptor_5.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_5.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_5.MDC Descr - Scale
V_MDCDescriptor_5.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 6 Mode = 0:
Measuring Data Channel 6
V_MDCDescriptor_6.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_6.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_6.MDC Descr - Scale
V_MDCDescriptor_6.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 6 Mode = 1:
Measuring Data Channel 6
V_MDCDescriptor_6.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_6.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_6.MDC Descr - Scale
V_MDCDescriptor_6.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 7 Mode = 0:
Measuring Data Channel 7
V_MDCDescriptor_7.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_7.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_7.MDC Descr - Scale
V_MDCDescriptor_7.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 7 Mode = 1:
Measuring Data Channel 7
V_MDCDescriptor_7.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_7.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_7.MDC Descr - Scale
V_MDCDescriptor_7.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 8 Mode = 0:
Measuring Data Channel 8
V_MDCDescriptor_8.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_8.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_8.MDC Descr - Scale
V_MDCDescriptor_8.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 8 Mode = 1:
Measuring Data Channel 8
V_MDCDescriptor_8.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_8.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_8.MDC Descr - Scale
V_MDCDescriptor_8.MDC Descr - Unit
Run Counters
V_AllTimeRunTime.Run counter * 0.25 h
V_ResetableRunTime.Run counter * 0.25 h
Event Timers
V_AllTimeRunTimeEventTime.Event Time * 0.25 h
V_ResetableRunTimeEventTime.Event Time * 0.25 h

Commissioning Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag
V_CP_FunctionTag
V_CP_LocationTag

Parameters Menu
Service Functions
V_SystemCommand, Button:=129
Description=The parameters of the technology-specific application are set to default values. Identification parameters remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master.
V_SystemCommand, Button:=131
Description=The parameters of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port!
Access Locks
V_DeviceAccessLocks.Local Parameterization
V_DeviceAccessLocks.Local User Interface
Vendor Specific Configuration
V_Vendor_Specific_Configuration.Process Data Input Configuration
V_Vendor_Specific_Configuration.IOL Filter Time ms
V_Vendor_Specific_Configuration.Secondary Output Function
V_Vendor_Specific_Configuration.PFM Input Port Selection
V_Vendor_Specific_Configuration.Analog In 1 Mode
V_Vendor_Specific_Configuration.Analog In 2 Mode
V_Vendor_Specific_Configuration.Analog In 3 Mode
V_Vendor_Specific_Configuration.Analog In 4 Mode
V_Vendor_Specific_Configuration.Analog In 5 Mode
V_Vendor_Specific_Configuration.Analog In 6 Mode
V_Vendor_Specific_Configuration.Analog In 7 Mode
V_Vendor_Specific_Configuration.Analog In 8 Mode
Pulse Frequency Configuration
V_PulseFrequencyConfiguration.Near Frequency Hz
V_PulseFrequencyConfiguration.Far Frequency Hz
V_PulseFrequencyLOSFrequency.Pulse Frequency LOS Frequency Hz
Channel 1 Setpoints
V_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 2 Setpoints
V_SSC2_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC2_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC2_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC2_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC2_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC2_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 3 Setpoints
V_SSC3_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC3_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC3_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC3_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC3_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC3_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 4 Setpoints
V_SSC4_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC4_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC4_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC4_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC4_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC4_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 5 Setpoints
V_SSC5_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC5_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC5_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC5_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC5_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC5_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 6 Setpoints
V_SSC6_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC6_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC6_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC6_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC6_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC6_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 7 Setpoints
V_SSC7_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC7_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC7_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC7_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC7_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC7_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 8 Setpoints
V_SSC8_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC8_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC8_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC8_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC8_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC8_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6

Observation Menu
If V_Vendor_Specific_Configuration.Analog In 1 Mode = 0:
Process Data Input Channel 1
V_ProcessDataInput.1 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 1 Mode = 1:
Process Data Input Channel 1
V_ProcessDataInput.1 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 2 Mode = 0:
Process Data Input Channel 2
V_ProcessDataInput.5 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 2 Mode = 1:
Process Data Input Channel 2
V_ProcessDataInput.5 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 3 Mode = 0:
Process Data Input Channel 3
V_ProcessDataInput.9 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 3 Mode = 1:
Process Data Input Channel 3
V_ProcessDataInput.9 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 4 Mode = 0:
Process Data Input Channel 4
V_ProcessDataInput.13 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 4 Mode = 1:
Process Data Input Channel 4
V_ProcessDataInput.13 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 5 Mode = 0:
Process Data Input Channel 5
V_ProcessDataInput.17 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 5 Mode = 1:
Process Data Input Channel 5
V_ProcessDataInput.17 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 6 Mode = 0:
Process Data Input Channel 6
V_ProcessDataInput.21 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 6 Mode = 1:
Process Data Input Channel 6
V_ProcessDataInput.21 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 7 Mode = 0:
Process Data Input Channel 7
V_ProcessDataInput.25 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 7 Mode = 1:
Process Data Input Channel 7
V_ProcessDataInput.25 * 1E-06 A, Dec.6
If V_Vendor_Specific_Configuration.Analog In 8 Mode = 0:
Process Data Input Channel 8
V_ProcessDataInput.29 * 0.001 V
If V_Vendor_Specific_Configuration.Analog In 8 Mode = 1:
Process Data Input Channel 8
V_ProcessDataInput.29 * 1E-06 A, Dec.6

Diagnosis Menu
Service Functions
V_SystemCommand, Button:=126
Description=The visual indicators of the device are switched to the localization display pattern, which makes it easier to spot a device in an application.
V_SystemCommand, Button:=127
Description=The localization indication pattern is stopped. The optical indicators of the device will show again the device specific states of operation.
Device Status Information
V_DeviceStatus
V_DetailedDeviceStatus
If V_Vendor_Specific_Configuration.Analog In 1 Mode = 0:
Measuring Data Channel 1
V_MDCDescriptor.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor.MDC Descr - Scale
V_MDCDescriptor.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 1 Mode = 1:
Measuring Data Channel 1
V_MDCDescriptor.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor.MDC Descr - Scale
V_MDCDescriptor.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 2 Mode = 0:
Measuring Data Channel 2
V_MDCDescriptor_2.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_2.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_2.MDC Descr - Scale
V_MDCDescriptor_2.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 2 Mode = 1:
Measuring Data Channel 2
V_MDCDescriptor_2.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_2.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_2.MDC Descr - Scale
V_MDCDescriptor_2.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 3 Mode = 0:
Measuring Data Channel 3
V_MDCDescriptor_3.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_3.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_3.MDC Descr - Scale
V_MDCDescriptor_3.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 3 Mode = 1:
Measuring Data Channel 3
V_MDCDescriptor_3.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_3.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_3.MDC Descr - Scale
V_MDCDescriptor_3.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 4 Mode = 0:
Measuring Data Channel 4
V_MDCDescriptor_4.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_4.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_4.MDC Descr - Scale
V_MDCDescriptor_4.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 4 Mode = 1:
Measuring Data Channel 4
V_MDCDescriptor_4.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_4.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_4.MDC Descr - Scale
V_MDCDescriptor_4.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 5 Mode = 0:
Measuring Data Channel 5
V_MDCDescriptor_5.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_5.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_5.MDC Descr - Scale
V_MDCDescriptor_5.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 5 Mode = 1:
Measuring Data Channel 5
V_MDCDescriptor_5.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_5.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_5.MDC Descr - Scale
V_MDCDescriptor_5.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 6 Mode = 0:
Measuring Data Channel 6
V_MDCDescriptor_6.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_6.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_6.MDC Descr - Scale
V_MDCDescriptor_6.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 6 Mode = 1:
Measuring Data Channel 6
V_MDCDescriptor_6.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_6.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_6.MDC Descr - Scale
V_MDCDescriptor_6.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 7 Mode = 0:
Measuring Data Channel 7
V_MDCDescriptor_7.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_7.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_7.MDC Descr - Scale
V_MDCDescriptor_7.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 7 Mode = 1:
Measuring Data Channel 7
V_MDCDescriptor_7.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_7.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_7.MDC Descr - Scale
V_MDCDescriptor_7.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 8 Mode = 0:
Measuring Data Channel 8
V_MDCDescriptor_8.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_8.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_8.MDC Descr - Scale
V_MDCDescriptor_8.MDC Descr - Unit
If V_Vendor_Specific_Configuration.Analog In 8 Mode = 1:
Measuring Data Channel 8
V_MDCDescriptor_8.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_8.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_8.MDC Descr - Scale
V_MDCDescriptor_8.MDC Descr - Unit
Run Counters
V_AllTimeRunTime.Run counter * 0.25 h
V_ResetableRunTime.Run counter * 0.25 h
Event Timers
V_AllTimeRunTimeEventTime.Event Time * 0.25 h
V_ResetableRunTimeEventTime.Event Time * 0.25 h

Note: This page shows the content of an IODD file transformed into HTML format. In the case of disparity between this and the XML view, the content of the XML file takes precedence.
Created by IODD Viewer V1.4.