| B55 |
| Vendor ID |
451 (0x01c3) |
 |
| Vendor Name |
Banner Engineering Corporation |
| Vendor Text |
More Sensors. More Solutions. |
| Vendor URL |
www.bannerengineering.com/io-link |
| Device ID |
459009 (0x070101) |
| DeviceFamily |
B55 |
| Features |
| Block Parameter |
yes |
| Data Storage |
yes |
| Profile Characteristic |
0x4000 (Common Application Profile: Identification and Diagnosis) |
| Supported Access Locks |
Parameter: no, Data Storage: no, Local Parameterization: yes, Local User Interface: yes |
| Communication |
| IO-Link Revision |
V1.1 |
| Transmission Rate | 38400 bit/s (COM2) |
| Minimum Cycle Time |
2.9 ms |
| SIO Mode Supported |
yes |
| M-Sequence Capability | PREOPERATE = TYPE_1_V with 8 octets on-request data OPERATE = TYPE_2_V with 2 octets on-request data ISDU supported |
| Device Variant |
B55 |
| Description |
Wide Beam Retro Sensor |
| Product ID |
B55 |
| Device Icon |
 |
| Device Symbol |
 |
| Connection Type | M12-4 connector |
| - pin 1 |
brown; L+ |
| - pin 2 |
white; Other; Discrete Output |
| - pin 3 |
(light) blue; L- |
| - pin 4 |
black; C/Q |
| subindex |
bit offset |
data type |
allowed values |
default value |
acc. restr. |
mod. other var. |
excl. from DS |
name |
description |
| 1 |
120 |
8-bit UInteger |
|
|
ro |
|
|
Reserved |
|
| 2 |
112 |
8-bit UInteger |
|
|
ro |
|
|
Master Cycle Time |
Communication: Current communication cycle duration used by the master. This value defines the process data cycle. |
| 3 |
104 |
8-bit UInteger |
|
|
ro |
|
|
Min Cycle Time |
Communication: Minimum communication cycle duration supported by the device. This value defines the lowest possible process data cycle. |
| 4 |
96 |
8-bit UInteger |
|
|
ro |
|
|
M-Sequence Capability |
Communication: Information on the structure and the supported features of the communication messages. |
| 5 |
88 |
8-bit UInteger |
|
17 |
ro |
|
|
IO-Link Revision ID |
Communication: Identifier for the currently used communication protocol revision. |
| 6 |
80 |
8-bit UInteger |
|
|
ro |
|
|
Process Data Input Length |
Communication: Information on width and features of the process input data (Process Data from Device to Master). |
| 7 |
72 |
8-bit UInteger |
|
|
ro |
|
|
Process Data Output Length |
Communication: Information on width of the process output data (Process Data from Master to Device). |
| 8 |
64 |
8-bit UInteger |
|
|
ro |
|
|
Vendor ID 1 |
Identification: Highest octet of the Vendor ID. Combined with the parameter Vendor ID 2, this parameter defines the 16-bit value of the unique Vendor ID as assigned by the IO-Link Community. |
| 9 |
56 |
8-bit UInteger |
|
|
ro |
|
|
Vendor ID 2 |
Identification: Lowest octet of the Vendor ID. Combined with the parameter Vendor ID 1, this parameter defines the 16-bit value of the unique Vendor ID as assigned by the IO-Link Community. |
| 10 |
48 |
8-bit UInteger |
|
|
ro |
|
|
Device ID 1 |
Identification: Highest octet of the Device ID. Combined with the parameters Device ID 2 and 3, this parameter defines the 24-bit value of the vendor-specific Device ID. |
| 11 |
40 |
8-bit UInteger |
|
|
ro |
|
|
Device ID 2 |
Identification: Middle octet of the Device ID. Combined with the parameters Device ID 1 and 3, this parameter defines the 24-bit value of the vendor-specific Device ID. |
| 12 |
32 |
8-bit UInteger |
|
|
ro |
|
|
Device ID 3 |
Identification: Lowest octet of the Device ID. Combined with the parameters Device ID 1 and 2, this parameter defines the 24-bit value of the vendor-specific Device ID. |
| 13 |
24 |
8-bit UInteger |
|
|
ro |
|
|
Reserved |
|
| 14 |
16 |
8-bit UInteger |
|
|
ro |
|
|
Reserved |
|
| 15 |
8 |
8-bit UInteger |
|
|
ro |
|
|
Reserved |
|
| 16 |
0 |
8-bit UInteger |
|
|
wo |
X |
|
System Command |
Application: Command interface for devices without ISDU support. Validity and execution of commands are not confirmed. |
| subindex |
bit offset |
data type |
allowed values |
default value |
acc. restr. |
mod. other var. |
excl. from DS |
name |
description |
| 1 |
0 |
Boolean |
false = Unlocked, true = Locked |
|
|
|
|
Parameter Write Access |
This lock prevents the write access to all read/write parameters of the device except for the parameter 'Device Access Locks'. |
| 2 |
1 |
Boolean |
false = Unlocked, true = Locked |
|
|
|
|
Data Storage |
This lock prevents the write access to the device parameters via the data storage mechanism. |
| 3 |
2 |
Boolean |
false = Unlocked, true = Locked |
false |
|
|
|
Local Parameterization |
This lock prevents the device settings from being changed via local operating elements on the device. |
| 4 |
3 |
Boolean |
false = Unlocked, true = Locked |
false |
|
|
|
Local User Interface |
This lock prevents the access to the device settings and display via a local user interface. The user interface is disabled. |
| subindex |
bit offset |
data type |
allowed values |
default value |
acc. restr. |
mod. other var. |
excl. from DS |
name |
description |
| 1 |
176 |
8-bit UInteger |
0 = Unlocked, 1 = Locked |
0 |
|
|
|
Sensor Button Lockout |
Sensor Button Lockout |
| 2 |
168 |
8-bit UInteger |
0 = Low, 1 = Standard, 2 = High |
1 |
|
|
|
Sensitivity |
Sensitivity |
| 3 |
160 |
8-bit UInteger |
0 = Disabled, 1 = Remote Teach, 2 = Detection Output, 3 = Complementary Output, 4 = Health Output, 5 = Alarm Output |
3 |
|
|
|
Pin2/Channel2 Function |
Pin2/Channel2 Function |
| 4 |
152 |
8-bit UInteger |
0 = NPN, 1 = PNP, 2 = Pin 2 PNP, Pin 4 Push/Pull |
2 |
|
|
|
Pin2/Pin4 Polarity |
Polarity of Pins 2 and 4 |
| 5 |
144 |
8-bit UInteger |
0 = Light Operate, 1 = Dark Operate |
1 |
|
|
|
Output Logic |
Output Logic |
| 6 |
136 |
8-bit UInteger |
0 = No Delay, 1 = On/Off Delay |
0 |
|
|
|
Output Delay Mode |
Enables or disables delay function |
| 7 |
104 |
32-bit UInteger |
|
10 |
|
|
|
Output On Delay |
Output On Delay in ms |
| 8 |
72 |
32-bit UInteger |
|
10 |
|
|
|
Output Off Delay |
Output Off Delay in ms |
| 9 |
64 |
8-bit UInteger |
0 = Cancel Teach, 1 = Stop Teach |
1 |
|
|
|
Dynamic Teach Timeout Mode |
Dynamic Teach Timeout Mode |
| 10 |
32 |
32-bit UInteger |
|
120 |
|
|
|
Dynamic Teach Timeout Duration |
Dynamic Teach Timeout Duration in seconds |
| 11 |
24 |
8-bit UInteger |
|
20 |
|
|
|
Alarm Threshold |
Alarm Threshold - Set to 0% to disable alarm. Controls how much the threshold may drift down before turning on the Alarm. |
| 12 |
16 |
8-bit UInteger |
0 = Display Enabled, 1 = Display Disabled |
0 |
|
|
|
Display Disable |
All non-sensing LEDs on sensor enabled or disabled |
| 13 |
8 |
8-bit UInteger |
0 = Disabled, 1 = Enabled |
1 |
|
|
|
Drift Filter Enable |
Drift Filter Enable |
| 14 |
0 |
8-bit UInteger |
0 = Signal, 1 = Switchpoint Centric Signal |
0 |
|
|
|
Signal Mode |
Signal Mode - Signal places 100% at taught condition and 0% at no signal, Switchpoint Centric places 100% at taught condition and 50% at switchpoint. |
| Code | Type | Name | Description |
| 25376 (0x6320) | Error | Parameter error | Check datasheet and values |
| 36000 (0x8ca0) | Warning | All-time Run Time Event | Event indicating the corresponding configured running time has elapsed. |
| 36001 (0x8ca1) | Warning | Resettable Run Time Event | Event indicating the corresponding configured running time has elapsed. |
| 36003 (0x8ca3) | Notification | Teach Completed Event | Event indicating a teach has been completed. |
| 36004 (0x8ca4) | Notification | Factory Settings Restored Event | Event indicating that the factory settings have been restored. |
| 36007 (0x8ca7) | Notification | Teach Failed Event | Event indicating an invalid target condition was attempted to be taught. Taught setpoint was not updated. |
| 36097 (0x8d01) | Error | System Fault Event | Contact Banner Engineering to resolve. |
| Parameters Menu |
| Device Access Locks |
| V_DeviceAccessLocks.Local Parameterization |
| V_DeviceAccessLocks.Local User Interface |
|
| System Commands |
V_SystemCommand, Button:=129 Description=The parameters of the technology-specific application are set to default values. Identification parameters remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master. |
V_SystemCommand, Button:=131 Description=The parameters of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port! |
V_SystemCommand, Button:=80 Description=Single Value Teach |
V_SystemCommand, Button:=81 Description=Start Dynamic Teach |
V_SystemCommand, Button:=82 Description=Stop Dynamic Teach |
V_SystemCommand, Button:=83 Description=Cancel Teach |
| V_SystemCommand, Button:=164 |
| V_SystemCommand, Button:=162 |
| V_SystemCommand, Button:=163 |
|
| Configuration |
| V_Configuration.Sensor Button Lockout |
| V_Configuration.Sensitivity |
| V_Configuration.Pin2/Channel2 Function |
| V_Configuration.Pin2/Pin4 Polarity |
| V_Configuration.Output Logic |
| V_Configuration.Output Delay Mode |
| V_Configuration.Output On Delay ms |
| V_Configuration.Output Off Delay ms |
| V_Configuration.Dynamic Teach Timeout Mode |
| V_Configuration.Dynamic Teach Timeout Duration s |
| V_Configuration.Alarm Threshold % |
| V_Configuration.Display Disable |
| V_Configuration.Drift Filter Enable |
| V_Configuration.Signal Mode |
|
| Service Functions |
V_SystemCommand, Button:=129 Description=The parameters of the technology-specific application are set to default values. Identification parameters remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master. |
V_SystemCommand, Button:=131 Description=The parameters of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port! |
|
| Parameters Menu |
| Device Access Locks |
| V_DeviceAccessLocks.Local Parameterization |
| V_DeviceAccessLocks.Local User Interface |
|
| System Commands |
V_SystemCommand, Button:=129 Description=The parameters of the technology-specific application are set to default values. Identification parameters remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master. |
V_SystemCommand, Button:=131 Description=The parameters of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port! |
V_SystemCommand, Button:=80 Description=Single Value Teach |
V_SystemCommand, Button:=81 Description=Start Dynamic Teach |
V_SystemCommand, Button:=82 Description=Stop Dynamic Teach |
V_SystemCommand, Button:=83 Description=Cancel Teach |
| V_SystemCommand, Button:=164 |
| V_SystemCommand, Button:=162 |
| V_SystemCommand, Button:=163 |
|
| Configuration |
| V_Configuration.Sensor Button Lockout |
| V_Configuration.Sensitivity |
| V_Configuration.Pin2/Channel2 Function |
| V_Configuration.Pin2/Pin4 Polarity |
| V_Configuration.Output Logic |
| V_Configuration.Output Delay Mode |
| V_Configuration.Output On Delay ms |
| V_Configuration.Output Off Delay ms |
| V_Configuration.Dynamic Teach Timeout Mode |
| V_Configuration.Dynamic Teach Timeout Duration s |
| V_Configuration.Alarm Threshold % |
| V_Configuration.Display Disable |
| V_Configuration.Drift Filter Enable |
| V_Configuration.Signal Mode |
|
| Service Functions |
V_SystemCommand, Button:=129 Description=The parameters of the technology-specific application are set to default values. Identification parameters remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master. |
V_SystemCommand, Button:=131 Description=The parameters of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port! |
|
Note: This page shows the content of an IODD file transformed into HTML format. In the case of disparity between this and the XML view, the content of the XML file takes precedence.
Created by IODD Viewer V1.4.