| R50C-L-MDR-KQ |
| Vendor ID |
451 (0x01c3) |
 |
| Vendor Name |
Banner Engineering Corporation |
| Vendor Text |
More Sensors. More Solutions. |
| Vendor URL |
www.bannerengineering.com/io-link |
| Device ID |
659479 (0x0a1017) |
| DeviceFamily |
R50C Series |
| Features |
| Block Parameter |
yes |
| Data Storage |
yes |
| Profile Characteristic |
0x4000 (Common Application Profile: Identification and Diagnosis), 0x8101 (Function Class: Locator) |
| Supported Access Locks |
Parameter: no, Data Storage: no, Local Parameterization: no, Local User Interface: no |
| Communication |
| IO-Link Revision |
V1.1 |
| Transmission Rate | 38400 bit/s (COM2) |
| Minimum Cycle Time |
4 ms |
| SIO Mode Supported |
yes |
| M-Sequence Capability | PREOPERATE = TYPE_1_V with 8 octets on-request data OPERATE = TYPE_2_V with 2 octets on-request data ISDU supported |
| Device Variant |
R50C-L-MDR-KQ |
| Description |
R50C-L-MDR-KQ with IO-Link |
| Product ID |
R50C-L-MDR-KQ |
| Device Icon |
 |
| Device Symbol |
 |
| Connection Type | M12-4 connector |
| Connection Description |
IO-Link Euro QD |
| - pin 1 |
brown; L+ |
| - pin 2 |
white; NC |
| - pin 3 |
(light) blue; L- |
| - pin 4 |
black; C/Q |
| subindex |
bit offset |
data type |
allowed values |
default value |
acc. restr. |
mod. other var. |
excl. from DS |
name |
description |
| 1 |
29 |
Boolean |
false = Inactive, true = Active |
|
|
|
|
MDR Short Circuit |
MDR Short Circuit |
| 2 |
28 |
Boolean |
false = Current below limit, true = Current above limit |
|
|
|
|
MDR Overcurrent |
MDR Overcurrent |
| 3 |
27 |
Boolean |
false = Voltage within Range, true = Voltage above Range |
|
|
|
|
MDR OverVoltage |
MDR OverVoltage |
| 4 |
26 |
Boolean |
false = Voltage within Range, true = Voltage below Range |
|
|
|
|
MDR UnderVoltage |
MDR UnderVoltage |
| 5 |
25 |
Boolean |
false = Temp below limit, true = Temp above limit |
|
|
|
|
Block Temperature |
Block Temperature |
| 6 |
24 |
Boolean |
false = No Aux Power, true = Aux Power Present |
|
|
|
|
Aux Power |
Aux Power |
| 7 |
17 |
Boolean |
false = Inactive, true = Active |
|
|
|
|
Pin2-Channel 2 |
true (1) = Discrete1 Input Active. Note - even if Discrete1 is configured as an output, the active state will be reflected at the input |
| 8 |
16 |
Boolean |
false = Inactive, true = Active |
|
|
|
|
Pin4-Channel 1 |
true (1) = Discrete2 Input Active. Note - even if Discrete2 is configured as an output, the active state will be reflected at the input |
| 9 |
0 |
16-bit Integer |
|
|
|
|
|
Pin 5 - Analog Value |
Pin 5 - Analog Value |
| subindex |
bit offset |
data type |
allowed values |
default value |
acc. restr. |
mod. other var. |
excl. from DS |
name |
description |
| 1 |
120 |
8-bit UInteger |
|
|
ro |
|
|
Reserved |
|
| 2 |
112 |
8-bit UInteger |
|
|
ro |
|
|
Master Cycle Time |
Communication: Current communication cycle duration used by the master. This value defines the process data cycle. |
| 3 |
104 |
8-bit UInteger |
|
|
ro |
|
|
Min Cycle Time |
Communication: Minimum communication cycle duration supported by the device. This value defines the lowest possible process data cycle. |
| 4 |
96 |
8-bit UInteger |
|
|
ro |
|
|
M-Sequence Capability |
Communication: Information on the structure and the supported features of the communication messages. |
| 5 |
88 |
8-bit UInteger |
|
17 |
ro |
|
|
IO-Link Revision ID |
Communication: Identifier for the currently used communication protocol revision. |
| 6 |
80 |
8-bit UInteger |
|
|
ro |
|
|
Process Data Input Length |
Communication: Information on width and features of the process input data (Process Data from Device to Master). |
| 7 |
72 |
8-bit UInteger |
|
|
ro |
|
|
Process Data Output Length |
Communication: Information on width of the process output data (Process Data from Master to Device). |
| 8 |
64 |
8-bit UInteger |
|
|
ro |
|
|
Vendor ID 1 |
Identification: Highest octet of the Vendor ID. Combined with the parameter Vendor ID 2, this parameter defines the 16-bit value of the unique Vendor ID as assigned by the IO-Link Community. |
| 9 |
56 |
8-bit UInteger |
|
|
ro |
|
|
Vendor ID 2 |
Identification: Lowest octet of the Vendor ID. Combined with the parameter Vendor ID 1, this parameter defines the 16-bit value of the unique Vendor ID as assigned by the IO-Link Community. |
| 10 |
48 |
8-bit UInteger |
|
|
ro |
|
|
Device ID 1 |
Identification: Highest octet of the Device ID. Combined with the parameters Device ID 2 and 3, this parameter defines the 24-bit value of the vendor-specific Device ID. |
| 11 |
40 |
8-bit UInteger |
|
|
ro |
|
|
Device ID 2 |
Identification: Middle octet of the Device ID. Combined with the parameters Device ID 1 and 3, this parameter defines the 24-bit value of the vendor-specific Device ID. |
| 12 |
32 |
8-bit UInteger |
|
|
ro |
|
|
Device ID 3 |
Identification: Lowest octet of the Device ID. Combined with the parameters Device ID 1 and 2, this parameter defines the 24-bit value of the vendor-specific Device ID. |
| 13 |
24 |
8-bit UInteger |
|
|
ro |
|
|
Reserved |
|
| 14 |
16 |
8-bit UInteger |
|
|
ro |
|
|
Reserved |
|
| 15 |
8 |
8-bit UInteger |
|
|
ro |
|
|
Reserved |
|
| 16 |
0 |
8-bit UInteger |
|
|
wo |
X |
|
System Command |
Application: Command interface for devices without ISDU support. Validity and execution of commands are not confirmed. |
| subindex |
bit offset |
data type |
allowed values |
default value |
acc. restr. |
mod. other var. |
excl. from DS |
name |
description |
| 1 |
152 |
8-bit UInteger |
0 = NPN Input, 1 = PNP Input, 2 = NPN Output with Pull Up, 3 = PNP Output with Pull Down, 4 = NPN Output Push Pull, 5 = PNP Output Push Pull |
1 |
|
|
|
Discrete1 IO Selection |
|
| 2 |
144 |
8-bit UInteger |
0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3 = Off One-shot |
0 |
|
|
|
Discrete1 Delay Mode |
Discrete1 Delay Mode Selection |
| 3 |
112 |
32-bit Integer |
|
0 |
|
|
|
Discrete1 Delay Timer 1 |
Discrete1 On Delay, One-shot, Pulse-stretcher time or Totalizer Count |
| 4 |
80 |
32-bit Integer |
|
0 |
|
|
|
Discrete1 Delay Timer 2 |
Discrete1 Off Delay or Totalizer time. |
| 5 |
72 |
8-bit UInteger |
0 = NPN Input, 1 = PNP Input, 2 = NPN Output with Pull Up, 3 = PNP Output with Pull Down, 4 = NPN Output Push Pull, 5 = PNP Output Push Pull |
3 |
|
|
|
Discrete2 IO Selection |
|
| 6 |
64 |
8-bit UInteger |
0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3 = Off One-shot |
0 |
|
|
|
Discrete2 Delay Mode |
Discrete2 Delay Mode Selection |
| 7 |
32 |
32-bit Integer |
|
0 |
|
|
|
Discrete2 Delay Timer 1 |
Discrete2 On Delay, One-shot, Pulse-stretcher time or Totalizer Count |
| 8 |
0 |
32-bit Integer |
|
0 |
|
|
|
Discrete2 Delay Timer 2 |
Discrete2 Off Delay or Totalizer time |
| subindex |
bit offset |
data type |
allowed values |
default value |
acc. restr. |
mod. other var. |
excl. from DS |
name |
description |
| 1 |
65 |
Boolean |
false = Do Not Reset, true = Reset |
false |
|
|
|
Port1 Discrete1 |
If set to [Reset], Discrete1 metrics will be reset. Note - the Count value can be set to a non-zero value using [Port# Discrete1 Reset Count] |
| 2 |
64 |
Boolean |
false = Do Not Reset, true = Reset |
false |
|
|
|
Port1 Discrete2 |
If set to [Reset], Discrete2 metrics will be reset. Note - the Count value can be set to a non-zero value using [Port# Discrete2 Reset Count] |
| 3 |
32 |
32-bit Integer |
0..2147483647 |
0 |
|
|
|
Port1 Discrete1 Reset Count |
|
| 4 |
0 |
32-bit Integer |
0..2147483647 |
0 |
|
|
|
Port1 Discrete2 Reset Count |
|
| Parameters Menu |
| Service Functions |
V_SystemCommand, Button:=129 Description=The parameters of the technology-specific application are set to default values. Identification parameters remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master. |
V_SystemCommand, Button:=131 Description=The parameters of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port! |
|
| Executable Commands |
| V_SystemCommand, Button:=126 |
| V_SystemCommand, Button:=127 |
| V_SystemCommand, Button:=164 |
|
| Selectable Metric Reset |
| V_Selectable_Metric_Reset.Port1 Discrete1 |
| V_Selectable_Metric_Reset.Port1 Discrete2 |
| V_Selectable_Metric_Reset.Port1 Discrete1 Reset Count |
| V_Selectable_Metric_Reset.Port1 Discrete2 Reset Count |
|
| Motor Run time Configuration |
| V_MotorOnCurrentSetting.Motor Current ON Setting mA |
| V_MotorOnCurrentSetting.Resettable Motor Run Time * 0.25 h |
|
| Input Configuration |
| V_WireMode |
|
| Configuration |
| Port1 Configuration |
| V_Port1_Configuration.Discrete1 IO Selection |
| V_Port1_Configuration.Discrete1 Delay Mode |
| V_Port1_Configuration.Discrete1 Delay Timer 1 ms |
| V_Port1_Configuration.Discrete1 Delay Timer 2 ms |
| V_Port1_Configuration.Discrete2 IO Selection |
| V_Port1_Configuration.Discrete2 Delay Mode |
| V_Port1_Configuration.Discrete2 Delay Timer 1 ms |
| V_Port1_Configuration.Discrete2 Delay Timer 2 ms |
|
| Block Configuration |
| V_Block_Configuration.Temperature High Setpoint |
| V_Block_Configuration.Temperature Scale |
| V_Block_Configuration.Undervoltage Alarm Setpoint mV |
| V_Block_Configuration.Overvoltage Alarm Setpoint mV |
| V_Block_Configuration.Analog Fix Speed Setting mV |
|
| Motor Control Configuration |
| V_Motor_Control_Configuration.Motor Power Enable |
| V_Motor_Control_Configuration.Maximum Analog Setting mV |
| V_Motor_Control_Configuration.Maximum Current Setting mA |
| V_Motor_Control_Configuration.Current In-Rush Delay Setting ms |
| V_Motor_Control_Configuration.Ramp On Delay ms |
| V_Motor_Control_Configuration.Ramp Off Delay ms |
|
| Monitoring |
| V_Monitoring.Temperature Fahrenheit Reading * 1 °F, Dec.2 |
| V_Monitoring.Temperature Celsius Reading * 1 °C, Dec.2 |
| V_Monitoring.Block Voltage Reading * 1 V, Dec.4 |
| V_Monitoring.Current Reading * 1 A, Dec.4 |
|
|
| Parameters Menu |
| Service Functions |
V_SystemCommand, Button:=129 Description=The parameters of the technology-specific application are set to default values. Identification parameters remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master. |
V_SystemCommand, Button:=131 Description=The parameters of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port! |
|
| Executable Commands |
| V_SystemCommand, Button:=126 |
| V_SystemCommand, Button:=127 |
| V_SystemCommand, Button:=164 |
|
| Selectable Metric Reset |
| V_Selectable_Metric_Reset.Port1 Discrete1 |
| V_Selectable_Metric_Reset.Port1 Discrete2 |
| V_Selectable_Metric_Reset.Port1 Discrete1 Reset Count |
| V_Selectable_Metric_Reset.Port1 Discrete2 Reset Count |
|
| Motor Run time Configuration |
| V_MotorOnCurrentSetting.Motor Current ON Setting mA |
| V_MotorOnCurrentSetting.Resettable Motor Run Time * 0.25 h |
|
| Input Configuration |
| V_WireMode |
|
| Configuration |
| Port1 Configuration |
| V_Port1_Configuration.Discrete1 IO Selection |
| V_Port1_Configuration.Discrete1 Delay Mode |
| V_Port1_Configuration.Discrete1 Delay Timer 1 ms |
| V_Port1_Configuration.Discrete1 Delay Timer 2 ms |
| V_Port1_Configuration.Discrete2 IO Selection |
| V_Port1_Configuration.Discrete2 Delay Mode |
| V_Port1_Configuration.Discrete2 Delay Timer 1 ms |
| V_Port1_Configuration.Discrete2 Delay Timer 2 ms |
|
| Block Configuration |
| V_Block_Configuration.Temperature High Setpoint |
| V_Block_Configuration.Temperature Scale |
| V_Block_Configuration.Undervoltage Alarm Setpoint mV |
| V_Block_Configuration.Overvoltage Alarm Setpoint mV |
| V_Block_Configuration.Analog Fix Speed Setting mV |
|
| Motor Control Configuration |
| V_Motor_Control_Configuration.Motor Power Enable |
| V_Motor_Control_Configuration.Maximum Analog Setting mV |
| V_Motor_Control_Configuration.Maximum Current Setting mA |
| V_Motor_Control_Configuration.Current In-Rush Delay Setting ms |
| V_Motor_Control_Configuration.Ramp On Delay ms |
| V_Motor_Control_Configuration.Ramp Off Delay ms |
|
| Monitoring |
| V_Monitoring.Temperature Fahrenheit Reading * 1 °F, Dec.2 |
| V_Monitoring.Temperature Celsius Reading * 1 °C, Dec.2 |
| V_Monitoring.Block Voltage Reading * 1 V, Dec.4 |
| V_Monitoring.Current Reading * 1 A, Dec.4 |
|
|