Version: V1.2Release Date: 2025-03-06


S15S-TH-KQ
Vendor ID 451 (0x01c3) Vendor Logo
Vendor Name Banner Engineering Corporation
Vendor Text More Sensors. More Solutions.
Vendor URL www.bannerengineering.com/io-link
Device ID 663553 (0x0a2001)
DeviceFamily S15S Series
Features
Block Parameter yes
Data Storage yes
Profile Characteristic 0x0001 (Device Profile: Generic Profiled Sensor), 0x4000 (Common Application Profile: Identification and Diagnosis)
Supported Access Locks Parameter: no, Data Storage: no, Local Parameterization: no, Local User Interface: no
Communication
IO-Link Revision V1.1
Transmission Rate38400 bit/s (COM2)
Minimum Cycle Time 4 ms
SIO Mode Supported no
M-Sequence CapabilityPREOPERATE = TYPE_1_V with 8 octets on-request data
OPERATE = TYPE_2_V with 2 octets on-request data
ISDU supported
Device Variant S15S-TH-KQ
Description S15S-TH-KQ with IO-Link
Product ID S15S-TH-KQ
Device Icon Device Icon
Device Symbol Device Symbol
Connection TypeM12-4 connector
Connection Description IO-Link Euro QD
- pin 1 brown; L+
- pin 2 white; NC
- pin 3 (light) blue; L-
- pin 4 black; C/Q

ProcessData id=PDin_SmartSensorFahrenheit (condition V_ProcessDataMode = 1)

ProcessDataIn "Process Data In" id=V_PDin_SmartSensorFahrenheit_DataRef

bit length: 112
data type: 112-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 80 16-bit Integer Temperature Value
2 72 8-bit Integer Temperature Scale
3 65 Boolean Temperature Under Threshold
4 64 Boolean Temperature Over Threshold
5 48 16-bit Integer Relative Humidity Value
6 40 8-bit Integer Relative Humidity Scale
7 33 Boolean Relative Humidity Under Threshold
8 32 Boolean Relative Humidity Over Threshold
9 16 16-bit Integer Dew Point Value
10 8 8-bit Integer Dew Point Scale
11 1 Boolean Dew Point Under Threshold
12 0 Boolean Dew Point Over Threshold
Octet 0
bit offset 111 110 109 108 107 106 105 104
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 1
bit offset 103 102 101 100 99 98 97 96
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 2
bit offset 95 94 93 92 91 90 89 88
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 3
bit offset 87 86 85 84 83 82 81 80
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 4
bit offset 79 78 77 76 75 74 73 72
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 5
bit offset 71 70 69 68 67 66 65 64
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 3 4
Octet 6
bit offset 63 62 61 60 59 58 57 56
subindex 5
element bit 15 14 13 12 11 10 9 8
Octet 7
bit offset 55 54 53 52 51 50 49 48
subindex 5
element bit 7 6 5 4 3 2 1 0
Octet 8
bit offset 47 46 45 44 43 42 41 40
subindex 6
element bit 7 6 5 4 3 2 1 0
Octet 9
bit offset 39 38 37 36 35 34 33 32
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 7 8
Octet 10
bit offset 31 30 29 28 27 26 25 24
subindex 9
element bit 15 14 13 12 11 10 9 8
Octet 11
bit offset 23 22 21 20 19 18 17 16
subindex 9
element bit 7 6 5 4 3 2 1 0
Octet 12
bit offset 15 14 13 12 11 10 9 8
subindex 10
element bit 7 6 5 4 3 2 1 0
Octet 13
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 11 12

ProcessData id=PDin_SmartSensorCelsius (condition V_ProcessDataMode = 2)

ProcessDataIn "Process Data In" id=V_PDin_SmartSensorCelsius_DataRef

bit length: 112
data type: 112-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 80 16-bit Integer Temperature Value
2 72 8-bit Integer Temperature Scale
3 65 Boolean Temperature Under Threshold
4 64 Boolean Temperature Over Threshold
5 48 16-bit Integer Relative Humidity Value
6 40 8-bit Integer Relative Humidity Scale
7 33 Boolean Relative Humidity Under Threshold
8 32 Boolean Relative Humidity Over Threshold
9 16 16-bit Integer Dew Point Value
10 8 8-bit Integer Dew Point Scale
11 1 Boolean Dew Point Under Threshold
12 0 Boolean Dew Point Over Threshold
Octet 0
bit offset 111 110 109 108 107 106 105 104
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 1
bit offset 103 102 101 100 99 98 97 96
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 2
bit offset 95 94 93 92 91 90 89 88
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 3
bit offset 87 86 85 84 83 82 81 80
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 4
bit offset 79 78 77 76 75 74 73 72
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 5
bit offset 71 70 69 68 67 66 65 64
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 3 4
Octet 6
bit offset 63 62 61 60 59 58 57 56
subindex 5
element bit 15 14 13 12 11 10 9 8
Octet 7
bit offset 55 54 53 52 51 50 49 48
subindex 5
element bit 7 6 5 4 3 2 1 0
Octet 8
bit offset 47 46 45 44 43 42 41 40
subindex 6
element bit 7 6 5 4 3 2 1 0
Octet 9
bit offset 39 38 37 36 35 34 33 32
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 7 8
Octet 10
bit offset 31 30 29 28 27 26 25 24
subindex 9
element bit 15 14 13 12 11 10 9 8
Octet 11
bit offset 23 22 21 20 19 18 17 16
subindex 9
element bit 7 6 5 4 3 2 1 0
Octet 12
bit offset 15 14 13 12 11 10 9 8
subindex 10
element bit 7 6 5 4 3 2 1 0
Octet 13
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 11 12

ProcessData id=PDin_FloatingPointFahrenheit (condition V_ProcessDataMode = 3)

ProcessDataIn "Process Data In" id=V_PDin_FloatingPointFahrenheit_DataRef

bit length: 112
data type: 112-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Float32 Temperature Value
2 32 Float32 Relative Humidity Value
3 64 Float32 Dew Point Value
4 96 Boolean Temperature Under Threshold
5 97 Boolean Temperature Over Threshold
6 98 Boolean Relative Humidity Under Threshold
7 99 Boolean Relative Humidity Over Threshold
8 100 Boolean Dew Point Under Threshold
9 101 Boolean Dew Point Over Threshold
Octet 0
bit offset 111 110 109 108 107 106 105 104
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 1
bit offset 103 102 101 100 99 98 97 96
subindex / / / / / / / / / / / / 9 8 7 6 5 4
Octet 2
bit offset 95 94 93 92 91 90 89 88
subindex 3
element bit 31 30 29 28 27 26 25 24
Octet 3
bit offset 87 86 85 84 83 82 81 80
subindex 3
element bit 23 22 21 20 19 18 17 16
Octet 4
bit offset 79 78 77 76 75 74 73 72
subindex 3
element bit 15 14 13 12 11 10 9 8
Octet 5
bit offset 71 70 69 68 67 66 65 64
subindex 3
element bit 7 6 5 4 3 2 1 0
Octet 6
bit offset 63 62 61 60 59 58 57 56
subindex 2
element bit 31 30 29 28 27 26 25 24
Octet 7
bit offset 55 54 53 52 51 50 49 48
subindex 2
element bit 23 22 21 20 19 18 17 16
Octet 8
bit offset 47 46 45 44 43 42 41 40
subindex 2
element bit 15 14 13 12 11 10 9 8
Octet 9
bit offset 39 38 37 36 35 34 33 32
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 10
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 31 30 29 28 27 26 25 24
Octet 11
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 23 22 21 20 19 18 17 16
Octet 12
bit offset 15 14 13 12 11 10 9 8
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 13
bit offset 7 6 5 4 3 2 1 0
subindex 1
element bit 7 6 5 4 3 2 1 0

ProcessData id=PDin_FloatingPointCelsius (condition V_ProcessDataMode = 4)

ProcessDataIn "Process Data In" id=V_PDin_FloatingPointCelsius_DataRef

bit length: 112
data type: 112-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Float32 Temperature Value
2 32 Float32 Relative Humidity Value
3 64 Float32 Dew Point Value
4 96 Boolean Temperature Under Threshold
5 97 Boolean Temperature Over Threshold
6 98 Boolean Relative Humidity Under Threshold
7 99 Boolean Relative Humidity Over Threshold
8 100 Boolean Dew Point Under Threshold
9 101 Boolean Dew Point Over Threshold
Octet 0
bit offset 111 110 109 108 107 106 105 104
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 1
bit offset 103 102 101 100 99 98 97 96
subindex / / / / / / / / / / / / 9 8 7 6 5 4
Octet 2
bit offset 95 94 93 92 91 90 89 88
subindex 3
element bit 31 30 29 28 27 26 25 24
Octet 3
bit offset 87 86 85 84 83 82 81 80
subindex 3
element bit 23 22 21 20 19 18 17 16
Octet 4
bit offset 79 78 77 76 75 74 73 72
subindex 3
element bit 15 14 13 12 11 10 9 8
Octet 5
bit offset 71 70 69 68 67 66 65 64
subindex 3
element bit 7 6 5 4 3 2 1 0
Octet 6
bit offset 63 62 61 60 59 58 57 56
subindex 2
element bit 31 30 29 28 27 26 25 24
Octet 7
bit offset 55 54 53 52 51 50 49 48
subindex 2
element bit 23 22 21 20 19 18 17 16
Octet 8
bit offset 47 46 45 44 43 42 41 40
subindex 2
element bit 15 14 13 12 11 10 9 8
Octet 9
bit offset 39 38 37 36 35 34 33 32
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 10
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 31 30 29 28 27 26 25 24
Octet 11
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 23 22 21 20 19 18 17 16
Octet 12
bit offset 15 14 13 12 11 10 9 8
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 13
bit offset 7 6 5 4 3 2 1 0
subindex 1
element bit 7 6 5 4 3 2 1 0

Standard Variable "Direct Parameters - Page 1" index=0 id=V_DirectParameters_1

description: Comprises the required parameters defining the communication characteristics and identifiers for device validation.
data type: 128-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger ro Reserved
2 112 8-bit UInteger ro Master Cycle Time Communication: Current communication cycle duration used by the master. This value defines the process data cycle.
3 104 8-bit UInteger ro Min Cycle Time Communication: Minimum communication cycle duration supported by the device. This value defines the lowest possible process data cycle.
4 96 8-bit UInteger ro M-Sequence Capability Communication: Information on the structure and the supported features of the communication messages.
5 88 8-bit UInteger 17 ro IO-Link Revision ID Communication: Identifier for the currently used communication protocol revision.
6 80 8-bit UInteger ro Process Data Input Length Communication: Information on width and features of the process input data (Process Data from Device to Master).
7 72 8-bit UInteger ro Process Data Output Length Communication: Information on width of the process output data (Process Data from Master to Device).
8 64 8-bit UInteger ro Vendor ID 1 Identification: Highest octet of the Vendor ID. Combined with the parameter Vendor ID 2, this parameter defines the 16-bit value of the unique Vendor ID as assigned by the IO-Link Community.
9 56 8-bit UInteger ro Vendor ID 2 Identification: Lowest octet of the Vendor ID. Combined with the parameter Vendor ID 1, this parameter defines the 16-bit value of the unique Vendor ID as assigned by the IO-Link Community.
10 48 8-bit UInteger ro Device ID 1 Identification: Highest octet of the Device ID. Combined with the parameters Device ID 2 and 3, this parameter defines the 24-bit value of the vendor-specific Device ID.
11 40 8-bit UInteger ro Device ID 2 Identification: Middle octet of the Device ID. Combined with the parameters Device ID 1 and 3, this parameter defines the 24-bit value of the vendor-specific Device ID.
12 32 8-bit UInteger ro Device ID 3 Identification: Lowest octet of the Device ID. Combined with the parameters Device ID 1 and 2, this parameter defines the 24-bit value of the vendor-specific Device ID.
13 24 8-bit UInteger ro Reserved
14 16 8-bit UInteger ro Reserved
15 8 8-bit UInteger ro Reserved
16 0 8-bit UInteger wo X System Command Application: Command interface for devices without ISDU support. Validity and execution of commands are not confirmed.

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "System Command" index=2 id=V_SystemCommand

description: Command interface for applications. A positive acknowledge indicates the complete and correct finalization of the requested function.
data type: 8-bit UInteger
allowed values: 129 = Application Reset, 131 = Back-to-box
access rights: wo
modifies other variables

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Vendor Name" index=16 id=V_VendorName

description: The vendor name that is assigned to a Vendor ID.
data type: 30-octet String UTF-8
default value: "Banner Engineering Corporation"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176

octet 8 9 10 11 12 13 14 15
bit offset 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112

octet 16 17 18 19 20 21 22 23
bit offset 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48

octet 24 25 26 27 28 29  
bit offset 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  

Standard Variable "Vendor Text" index=17 id=V_VendorText

description: Additional information about the vendor.
data type: 29-octet String UTF-8
default value: "More Sensors. More Solutions."
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176 175 - 168

octet 8 9 10 11 12 13 14 15
bit offset 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104

octet 16 17 18 19 20 21 22 23
bit offset 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40

octet 24 25 26 27 28  
bit offset 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  

Standard Variable "Product Name" index=18 id=V_ProductName

description: Complete product name.
data type: 32-octet String UTF-8
default value: "S15S-TH-KQ"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product ID" index=19 id=V_ProductID

description: Vendor-specific product or type identification (e.g., item number or model number).
data type: 32-octet String UTF-8
default value: "S15S-TH-KQ"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product Text" index=20 id=V_ProductText

description: Additional product information for the device.
data type: 34-octet String UTF-8
default value: "S15S-TH-KQ"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 271 - 264 263 - 256 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208

octet 8 9 10 11 12 13 14 15
bit offset 207 - 200 199 - 192 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144

octet 16 17 18 19 20 21 22 23
bit offset 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80

octet 24 25 26 27 28 29 30 31
bit offset 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16

octet 32 33  
bit offset 15 - 8 7 - 0  

Standard Variable "Serial Number" index=21 id=V_SerialNumber

description: Unique, vendor-specific identifier of the individual device.
data type: 16-octet String UTF-8
default value: "SerialNumber"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Hardware Revision" index=22 id=V_HardwareRevision

description: Unique, vendor-specific identifier of the hardware revision of the individual device.
data type: 64-octet String UTF-8
default value: "HWVersion"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Firmware Revision" index=23 id=V_FirmwareRevision

description: Unique, vendor-specific identifier of the firmware revision of the individual device.
data type: 64-octet String UTF-8
default value: "V1.1"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Application-specific Tag" index=24 id=V_ApplicationSpecificTag

description: Possibility to mark a device with user- or application-specific information.
data type: 32-octet String UTF-8
default value: "More Sensors. More Solutions."
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Error Count" index=32 id=V_ErrorCount

description: Number of errors that occurred in the technology-specific application since power on or restart.
data type: 16-bit UInteger
access rights: ro
dynamic

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Standard Variable "Device Status" index=36 id=V_DeviceStatus

description: Indicator for the current device condition and diagnosis state.
data type: 8-bit UInteger
allowed values: 0 = Device is OK, 1 = Maintenance required, 2 = Out of specification, 3 = Functional check, 4 = Failure
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Detailed Device Status" index=37 id=V_DetailedDeviceStatus

description: List of all currently pending events in the device.
data type: Array[4] of 3-octet OctetString (subindex access not supported)
access rights: ro
dynamic

octet 0 1 2 3 4 5 6 7
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32
subindex 1 1 1 2 2 2 3 3

octet 8 9 10 11  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 3 4 4 4  

Variable "Function Tag" index=25 id=V_CP_FunctionTag

description: Possibility to mark a device with function-specific information.
data type: 32-octet String UTF-8
default value: "More Sensors. More Solutions."
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Location Tag" index=26 id=V_CP_LocationTag

description: Possibility to mark a device with location-specific information.
data type: 32-octet String UTF-8
default value: "More Sensors. More Solutions."
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "All-time Run Time" index=69 id=V_AllTimeRuntime

description: A run time counter that tracks the total time the sensor has been running since manufacture
data type: 32-bit Record (subindex access not supported)
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit UInteger Run Counter Run Counter

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Resettable Run Time" index=70 id=V_ResettableRuntime

description: A run time counter that can be written by the user
data type: 32-bit UInteger
default value: 0
access rights: rw
excluded from data storage

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Alarm Configuration" index=71 id=V_AlarmConfig

description: Alarm Configuration
data type: 384-bit Record
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 352 Float32 32 Temperature Low Threshold
2 320 Float32 120 Temperature High Threshold
3 288 Float32 0 Relative Humidity Low Threshold
4 256 Float32 100 Relative Humidity High Threshold
5 224 Float32 32 Dew Point Low Threshold
6 192 Float32 120 Dew Point High Threshold
7 160 Float32 0 Temperature On Delay
8 128 Float32 0 Temperature Off Delay
9 96 Float32 0 Relative Humidity On Delay
10 64 Float32 0 Relative Humidity Off Delay
11 32 Float32 0 Dew Point On Delay
12 0 Float32 0 Dew Point Off Delay

octet 0 1 2 3 4 5 6 7
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256
subindex 3 3 3 3 4 4 4 4
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192
subindex 5 5 5 5 6 6 6 6
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 24 25 26 27 28 29 30 31
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 7 7 7 7 8 8 8 8
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 32 33 34 35 36 37 38 39
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 9 9 9 9 10 10 10 10
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 40 41 42 43 44 45 46 47
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 11 11 11 11 12 12 12 12
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Alarm Counters" index=72 id=V_AlarmCounters

description: Alarm Counters
data type: 96-bit Record
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 80 16-bit UInteger 0 Temperature Low Counter
2 64 16-bit UInteger 0 Temperature High Counter
3 48 16-bit UInteger 0 Relative Humidity Low Counter
4 32 16-bit UInteger 0 Relative Humidity High Counter
5 16 16-bit UInteger 0 Dew Point Low Counter
6 0 16-bit UInteger 0 Dew Point High Counter

octet 0 1 2 3 4 5 6 7
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32
subindex 1 1 2 2 3 3 4 4
element bit 15 - 8 7 - 0 15 - 8 7 - 0 15 - 8 7 - 0 15 - 8 7 - 0

octet 8 9 10 11  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 5 5 6 6  
element bit 15 - 8 7 - 0 15 - 8 7 - 0  

Variable "Process Data Mode" index=80 id=V_ProcessDataMode

description: Defines the formatting of the Process Data.
data type: 8-bit UInteger
allowed values: 1 = Smart Sensor Profile, Fahrenheit, 2 = Smart Sensor Profile, Celsius, 3 = Floating Point, Fahrenheit, 4 = Floating Point, Celsius
default value: 1
access rights: rw
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Output Configuration" index=81 id=V_WireMode

description: Output Configuration
data type: 8-bit UInteger
allowed values: 0 = BannerBus, 1 = Discrete Output
default value: 0
access rights: rw
excluded from data storage

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Events

CodeTypeNameDescription
0 (0x0000)NotificationNo malfunction
20480 (0x5000)ErrorDevice hardware faultExchange device

Process Data Formatting

Formatting for Process Data id=V_PDin_SmartSensorFahrenheit_DataRef
Subindex 1: °F
Subindex 2:
Subindex 3:
Subindex 4:
Subindex 5: %
Subindex 6:
Subindex 7:
Subindex 8:
Subindex 9: °F
Subindex 10:
Subindex 11:
Subindex 12:

Formatting for Process Data id=V_PDin_SmartSensorCelsius_DataRef
Subindex 1: °C
Subindex 2:
Subindex 3:
Subindex 4:
Subindex 5: %
Subindex 6:
Subindex 7:
Subindex 8:
Subindex 9: °C
Subindex 10:
Subindex 11:
Subindex 12:

Formatting for Process Data id=V_PDin_FloatingPointFahrenheit_DataRef
Subindex 1: °F
Subindex 2: %
Subindex 3: °F
Subindex 4:
Subindex 5:
Subindex 6:
Subindex 7:
Subindex 8:
Subindex 9:

Formatting for Process Data id=V_PDin_FloatingPointCelsius_DataRef
Subindex 1: °C
Subindex 2: %
Subindex 3: °C
Subindex 4:
Subindex 5:
Subindex 6:
Subindex 7:
Subindex 8:
Subindex 9:

Operator Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductText
V_ProductID
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag, ro
V_CP_FunctionTag, ro
V_CP_LocationTag, ro

Parameters Menu
Process Data Mode
V_ProcessDataMode
Alarm Configuration
V_AlarmConfig.Temperature Low Threshold
V_AlarmConfig.Temperature High Threshold
V_AlarmConfig.Relative Humidity Low Threshold
V_AlarmConfig.Relative Humidity High Threshold
V_AlarmConfig.Dew Point Low Threshold
V_AlarmConfig.Dew Point High Threshold
V_AlarmConfig.Temperature On Delay
V_AlarmConfig.Temperature Off Delay
V_AlarmConfig.Relative Humidity On Delay
V_AlarmConfig.Relative Humidity Off Delay
V_AlarmConfig.Dew Point On Delay
V_AlarmConfig.Dew Point Off Delay

Observation Menu
Alarm Threshold Counters
V_AlarmCounters.Temperature Low Counter
V_AlarmCounters.Temperature High Counter
V_AlarmCounters.Relative Humidity Low Counter
V_AlarmCounters.Relative Humidity High Counter
V_AlarmCounters.Dew Point Low Counter
V_AlarmCounters.Dew Point High Counter

Maintenance Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag
V_CP_FunctionTag
V_CP_LocationTag

Parameters Menu
Executable Commands
V_SystemCommand, Button:=129
Description=The parameter of the technology-specific application are set to default values. Identification parameter remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master.
V_SystemCommand, Button:=131
Description=The parameter of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port!
Output Configuration
V_WireMode
Process Data Mode
V_ProcessDataMode
Alarm Configuration
V_AlarmConfig.Temperature Low Threshold
V_AlarmConfig.Temperature High Threshold
V_AlarmConfig.Relative Humidity Low Threshold
V_AlarmConfig.Relative Humidity High Threshold
V_AlarmConfig.Dew Point Low Threshold
V_AlarmConfig.Dew Point High Threshold
V_AlarmConfig.Temperature On Delay
V_AlarmConfig.Temperature Off Delay
V_AlarmConfig.Relative Humidity On Delay
V_AlarmConfig.Relative Humidity Off Delay
V_AlarmConfig.Dew Point On Delay
V_AlarmConfig.Dew Point Off Delay

Observation Menu
Alarm Threshold Counters
V_AlarmCounters.Temperature Low Counter
V_AlarmCounters.Temperature High Counter
V_AlarmCounters.Relative Humidity Low Counter
V_AlarmCounters.Relative Humidity High Counter
V_AlarmCounters.Dew Point Low Counter
V_AlarmCounters.Dew Point High Counter

Diagnosis Menu
All-time Run Time Counters
V_AllTimeRuntime.Run Counter * 0.25 h
Resettable Run Time Counters
V_ResettableRuntime * 0.25 h

Commissioning Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag
V_CP_FunctionTag
V_CP_LocationTag

Parameters Menu
Executable Commands
V_SystemCommand, Button:=129
Description=The parameter of the technology-specific application are set to default values. Identification parameter remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master.
V_SystemCommand, Button:=131
Description=The parameter of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port!
Output Configuration
V_WireMode
Process Data Mode
V_ProcessDataMode
Alarm Configuration
V_AlarmConfig.Temperature Low Threshold
V_AlarmConfig.Temperature High Threshold
V_AlarmConfig.Relative Humidity Low Threshold
V_AlarmConfig.Relative Humidity High Threshold
V_AlarmConfig.Dew Point Low Threshold
V_AlarmConfig.Dew Point High Threshold
V_AlarmConfig.Temperature On Delay
V_AlarmConfig.Temperature Off Delay
V_AlarmConfig.Relative Humidity On Delay
V_AlarmConfig.Relative Humidity Off Delay
V_AlarmConfig.Dew Point On Delay
V_AlarmConfig.Dew Point Off Delay

Observation Menu
Alarm Threshold Counters
V_AlarmCounters.Temperature Low Counter
V_AlarmCounters.Temperature High Counter
V_AlarmCounters.Relative Humidity Low Counter
V_AlarmCounters.Relative Humidity High Counter
V_AlarmCounters.Dew Point Low Counter
V_AlarmCounters.Dew Point High Counter

Diagnosis Menu
All-time Run Time Counters
V_AllTimeRuntime.Run Counter * 0.25 h
Resettable Run Time Counters
V_ResettableRuntime * 0.25 h