Version: V1.1Release Date: 2024-01-24


Q90R
Vendor ID 451 (0x01c3) Vendor Logo
Vendor Name Banner Engineering Corporation
Vendor Text More Sensors. More Solutions.
Vendor URL www.bannerengineering.com/io-link
Device ID 786434 (0x0c0002)
DeviceFamily Q90R Series
Features
Block Parameter yes
Data Storage yes
Profile Characteristic 0x0001 (Device Profile: Generic Profiled Sensor), 0x4000 (Common Application Profile: Identification and Diagnosis)
Supported Access Locks Parameter: no, Data Storage: no, Local Parameterization: no, Local User Interface: no
Communication
IO-Link Revision V1.1
Transmission Rate38400 bit/s (COM2)
Minimum Cycle Time 3.9 ms
SIO Mode Supported yes
M-Sequence CapabilityPREOPERATE = TYPE_1_V with 8 octets on-request data
OPERATE = TYPE_2_V with 2 octets on-request data
ISDU supported
Device Variant Q90R-4040-6KIQ
Description 60 GHz Radar
Product ID Q90R-4040-6KIQ
Device Icon Device Icon
Device Symbol Device Symbol
Connection TypeM12-5 connector
- pin 1 brown; L+
- pin 2 white; Other; Analog Output
- pin 3 (light) blue; L-
- pin 4 black; C/Q
- pin 5 grey (slate); NC; Remote Input/BannerBus
Device Variant Q90R-4040-6KUQ
Description 60 GHz Radar
Product ID Q90R-4040-6KUQ
Device Icon Device Icon
Device Symbol Device Symbol
Connection TypeM12-5 connector
- pin 1 brown; L+
- pin 2 white; Other; Analog Output
- pin 3 (light) blue; L-
- pin 4 black; C/Q
- pin 5 grey (slate); NC; Remote Input/BannerBus

ProcessData id=PD_ProcessDataMeasurement (condition V_Configuration.Process Data Layout = 0)

ProcessDataIn "Process Data Input" id=PD_ProcessDataInMeasurement

bit length: 48
data type: 48-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 32-bit Integer Distance Measurement Value Process Data Distance Measurement
2 8 8-bit Integer Measurement Scale The measurement device scale
3 2 Boolean false = No Target or Marginal, true = Valid Stability Stability State
4 1 Boolean false = Inactive, true = Active BDC1 State BDC1 State
5 0 Boolean false = Inactive, true = Active AO1 State AO1 State
Octet 0
bit offset 47 46 45 44 43 42 41 40
subindex 1
element bit 31 30 29 28 27 26 25 24
Octet 1
bit offset 39 38 37 36 35 34 33 32
subindex 1
element bit 23 22 21 20 19 18 17 16
Octet 2
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 3
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 4
bit offset 15 14 13 12 11 10 9 8
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 5
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 3 4 5

ProcessData id=PD_ProcessDataDistanceAmplitude (condition V_Configuration.Process Data Layout = 1)

ProcessDataIn "Process Data Input" id=PD_ProcessDataInDistanceAmplitude

bit length: 48
data type: 48-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 32-bit Integer Distance Measurement Value Process Data Distance Measurement
2 0 16-bit UInteger Excess Gain Measurement Value Process Data Excess Gain Measurement

octet 0 1 2 3 4 5  
bit offset 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1 2 2  
element bit 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0  

ProcessData id=PD_ProcessDataDistanceScaledAmplitude (condition V_Configuration.Process Data Layout = 2)

ProcessDataIn "Process Data Input" id=PD_ProcessDataInDistanceScaledAmplitude

bit length: 48
data type: 48-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 32-bit Integer Distance Measurement Value Process Data Distance Measurement
2 8 8-bit UInteger Excess Gain Measurement Value Process Data Excess Gain Measurement (restricted to 0-255x)
3 2 Boolean false = No Target or Marginal, true = Valid Stability Stability State
4 1 Boolean false = Inactive, true = Active BDC1 State BDC1 State
5 0 Boolean false = Inactive, true = Active AO1 State AO1 State
Octet 0
bit offset 47 46 45 44 43 42 41 40
subindex 1
element bit 31 30 29 28 27 26 25 24
Octet 1
bit offset 39 38 37 36 35 34 33 32
subindex 1
element bit 23 22 21 20 19 18 17 16
Octet 2
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 3
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 4
bit offset 15 14 13 12 11 10 9 8
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 5
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 3 4 5

Standard Variable "Direct Parameters - Page 1" index=0 id=V_DirectParameters_1

description: Comprises the required parameters defining the communication characteristics and identifiers for device validation.
data type: 128-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger ro Reserved
2 112 8-bit UInteger ro Master Cycle Time Communication: Current communication cycle duration used by the master. This value defines the process data cycle.
3 104 8-bit UInteger ro Min Cycle Time Communication: Minimum communication cycle duration supported by the device. This value defines the lowest possible process data cycle.
4 96 8-bit UInteger ro M-Sequence Capability Communication: Information on the structure and the supported features of the communication messages.
5 88 8-bit UInteger 17 ro IO-Link Revision ID Communication: Identifier for the currently used communication protocol revision.
6 80 8-bit UInteger ro Process Data Input Length Communication: Information on width and features of the process input data (Process Data from Device to Master).
7 72 8-bit UInteger ro Process Data Output Length Communication: Information on width of the process output data (Process Data from Master to Device).
8 64 8-bit UInteger ro Vendor ID 1 Identification: Highest octet of the Vendor ID. Combined with the parameter Vendor ID 2, this parameter defines the 16-bit value of the unique Vendor ID as assigned by the IO-Link Community.
9 56 8-bit UInteger ro Vendor ID 2 Identification: Lowest octet of the Vendor ID. Combined with the parameter Vendor ID 1, this parameter defines the 16-bit value of the unique Vendor ID as assigned by the IO-Link Community.
10 48 8-bit UInteger ro Device ID 1 Identification: Highest octet of the Device ID. Combined with the parameters Device ID 2 and 3, this parameter defines the 24-bit value of the vendor-specific Device ID.
11 40 8-bit UInteger ro Device ID 2 Identification: Middle octet of the Device ID. Combined with the parameters Device ID 1 and 3, this parameter defines the 24-bit value of the vendor-specific Device ID.
12 32 8-bit UInteger ro Device ID 3 Identification: Lowest octet of the Device ID. Combined with the parameters Device ID 1 and 2, this parameter defines the 24-bit value of the vendor-specific Device ID.
13 24 8-bit UInteger ro Reserved
14 16 8-bit UInteger ro Reserved
15 8 8-bit UInteger ro Reserved
16 0 8-bit UInteger wo X System Command Application: Command interface for devices without ISDU support. Validity and execution of commands are not confirmed.

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "System Command" index=2 id=V_SystemCommand

description: Command interface for applications. A positive acknowledge indicates the complete and correct finalization of the requested function.
data type: 8-bit UInteger
allowed values: 65 = SP1 Single Value Teach, 66 = SP2 Single Value Teach, 126 = Locator Start, 127 = Locator Stop, 129 = Application Reset, 131 = Back-to-box
access rights: wo
modifies other variables

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Vendor Name" index=16 id=V_VendorName

description: The vendor name that is assigned to a Vendor ID.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Vendor Text" index=17 id=V_VendorText

description: Additional information about the vendor.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product Name" index=18 id=V_ProductName

description: Complete product name.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product ID" index=19 id=V_ProductID

description: Vendor-specific product or type identification (e.g., item number or model number).
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product Text" index=20 id=V_ProductText

description: Additional product information for the device.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Serial Number" index=21 id=V_SerialNumber

description: Unique, vendor-specific identifier of the individual device.
data type: 16-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Hardware Revision" index=22 id=V_HardwareRevision

description: Unique, vendor-specific identifier of the hardware revision of the individual device.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Firmware Revision" index=23 id=V_FirmwareRevision

description: Unique, vendor-specific identifier of the firmware revision of the individual device.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Application-specific Tag" index=24 id=V_ApplicationSpecificTag

description: Possibility to mark a device with user- or application-specific information.
data type: 32-octet String UTF-8
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Error Count" index=32 id=V_ErrorCount

description: Number of errors that occurred in the technology-specific application since power on or restart.
data type: 16-bit UInteger
access rights: ro
dynamic

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Standard Variable "Device Status" index=36 id=V_DeviceStatus

description: Indicator for the current device condition and diagnosis state.
data type: 8-bit UInteger
allowed values: 0 = Device is OK, 1 = Maintenance required, 2 = Out of specification, 3 = Functional check, 4 = Failure
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Detailed Device Status" index=37 id=V_DetailedDeviceStatus

description: List of all currently pending events in the device.
data type: Array[6] of 3-octet OctetString (subindex access not supported)
access rights: ro
dynamic

octet 0 1 2 3 4 5 6 7
bit offset 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80
subindex 1 1 1 2 2 2 3 3

octet 8 9 10 11 12 13 14 15
bit offset 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16
subindex 3 4 4 4 5 5 5 6

octet 16 17  
bit offset 15 - 8 7 - 0  
subindex 6 6  

Standard Variable "PD Input" index=40 id=V_ProcessDataInput

description: Last valid process input data of the device.
data type: see ProcessDataIn!
access rights: ro
dynamic

Variable "Function Tag" index=25 id=V_CP_FunctionTag

description: Possibility to mark a device with function-specific information.
data type: 32-octet String UTF-8
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Location Tag" index=26 id=V_CP_LocationTag

description: Possibility to mark a device with location-specific information.
data type: 32-octet String UTF-8
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Teach-in Channel" index=58 id=V_TeachInChannel

description: The parameter 'Teach-in Channel' allows addressing the particular BDC or a set of BDCs for which the teach-in commands apply
data type: 8-bit Record (subindex access not supported)
access rights: rw
excluded from data storage

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = Default, 1 = BDC1, 192 = AO1 0 Teach-in Channel The parameter 'Teach-in Channel' allows addressing the particular BDC or a set of BDCs for which the teach-in commands apply

octet 0  
bit offset 7 - 0  
subindex 1  
element bit 7 - 0  

Variable "Teach-in Status" index=59 id=V_TeachStatus

description: The parameter 'Teach-in Status' provides feedback on the status and the results of the teach-in activities.
data type: 8-bit Record (subindex access not supported)
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 4-bit UInteger 0 = IDLE, 1 = SP1 SUCCESS, 2 = SP2 SUCCESS, 3 = SP12 SUCCESS, 4 = WAIT FOR COMMAND, 5 = BUSY, 7 = ERROR 0 Teach-in Status The parameter 'Teach-in Status' provides feedback on the status and the results of the teach-in activities.
2 4 Boolean 0 SP1 TP1 SP1 TP1
3 5 Boolean 0 SP1 TP2 SP1 TP2
4 6 Boolean 0 SP2 TP1 SP2 TP1
5 7 Boolean 0 SP2 TP2 SP2 TP2
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex 5 4 3 2 1
element bit         3 2 1 0

Variable "BDC1 Setpoints" index=60 id=V_BDC1_Setpoints

description: The reference value used for sensor switching (See IOL Smart Sensor Profile 9.2.5)
data type: 64-bit Record (subindex access not supported)
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit Integer Setpoint SP1 SP1 switch point in Switch or Window mode.
2 0 32-bit Integer Setpoint SP2 SP2 switch point in Window mode only.

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "BDC1 Configuration" index=61 id=V_BDC1_Configuration

description: Parameter coding of the Setpoint and Switchpoint parameter (See IOL Smart Sensor Profile 9.2.6)
data type: 32-bit Record
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 24 8-bit UInteger 0 = Light Operate (LO) - Discrete output is On while target is detected., 1 = Dark Operate (DO) - Discrete output is Off while target is detected. 0 Switch point logic Set LO/DO selection.
2 16 8-bit UInteger 1 = Switch Mode/Single Point Mode, 2 = Window Mode 1 BDC Mode Defines how the binary switching information is created on Setpoint parameters (SP1, SP2) and the current measurement value.
3 0 16-bit UInteger 50 Hysteresis Hysteresis value for the switchpoint

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 2 3 3  
element bit 7 - 0 7 - 0 15 - 8 7 - 0  

Variable "Configuration" index=64 id=V_Configuration

description: User selectable settings
data type: 232-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 224 8-bit UInteger 0 = Fast, 1 = Medium, 2 = Slow 1 Response Speed Speed at which the measurement is calculated
2 216 8-bit UInteger 0 = Strongest Peak, 1 = First Peak 1 Peak Select Mode Which target is chosen when multiple are present
3 208 8-bit UInteger 0 = NPN, 1 = PNP 1 Output Polarity Output Polarity
4 192 16-bit UInteger 0 Process Data Filter Time Time in milliseconds to average process data measurement between updates
5 184 8-bit UInteger 0 = Digital Measurement Sensor, 1 = Distance and Excess Gain, 2 = Distance and Excess Gain with Binary Data 0 Process Data Layout Process Data Layout
6 176 8-bit UInteger 0 = Disabled, 1 = Teach 0 Remote Input Mode Remote Input Mode
7 168 8-bit UInteger 0 = Enabled, 1 = Disabled 0 LEDs Disabled LEDs Disabled
8 136 32-bit Integer 100..10000 100 Amplitude Threshold Minimum amplitude required for target detection
9 128 8-bit UInteger 0 = Disabled, 1 = Enabled 0 Limit Filter Enabled Rate-of-change filter for the distance measurement
10 96 32-bit Integer 50..3600000 1000 Limit Filter Positive Hold Time Hold time for when distance change exceeds configured positive window
11 64 32-bit Integer 50..3600000 1000 Limit Filter Negative Hold Time Hold time for when distance change exceeds configured negative window
12 32 32-bit Integer 0..1000 150 Limit Filter Positive Distance Window size for distance changes going away from sensor (set to 0 to disable)
13 0 32-bit Integer 0..1000 150 Limit Filter Negative Distance Window size for distance changes going towards sensor (set to 0 to disable)

octet 0 1 2 3 4 5 6 7
bit offset 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176 175 - 168
subindex 1 2 3 4 4 5 6 7
element bit 7 - 0 7 - 0 7 - 0 15 - 8 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104
subindex 8 8 8 8 9 10 10 10
element bit 31 - 24 23 - 16 15 - 8 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8

octet 16 17 18 19 20 21 22 23
bit offset 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40
subindex 10 11 11 11 11 12 12 12
element bit 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8

octet 24 25 26 27 28  
bit offset 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 12 13 13 13 13  
element bit 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "BDC1 Vendor Specific Configuration" index=65 id=V_BDC1_VendorConfiguration

description: Vendor specific user selectable BDC1 settings
data type: 96-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 64 32-bit UInteger 0..60000 0 Delay On Delay time before output switches on. 0ms disables the delay.
2 32 32-bit UInteger 0..60000 500 Delay Off Delay time before output switches off. 0ms disables the delay.
3 0 32-bit Integer 100 Teach Offset Offset applied to taught switch point during single point teach.

octet 0 1 2 3 4 5 6 7
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 3 3 3 3  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Status" index=67 id=V_Status

description: Status
data type: 176-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 144 32-bit Integer Distance Measurement Distance Measurement
2 112 32-bit Integer Excess Gain Amount of signal measured over the minimum threshold
3 104 8-bit UInteger 0 = No Target, 1 = Marginal Target, 2 = Strong Target Stability Stability State
4 96 8-bit UInteger 0 = No Fault Present, 1 = Fault Present Fault Status Whether there is an error detected with the radar transceiver
5 64 32-bit Integer Analog Output Value Analog Output Value (V if voltage model, mA if current model)
6 32 32-bit Integer Temperature Internal temperature measurement
7 0 32-bit Integer Last Taught Temperature Internal temperature measurement the last time device was taught

octet 0 1 2 3 4 5 6 7
bit offset 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48
subindex 3 4 5 5 5 5 6 6
element bit 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16

octet 16 17 18 19 20 21  
bit offset 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 6 6 7 7 7 7  
element bit 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "All-time Run Time" index=69 id=V_AllTimeRuntime

description: A run time counter that tracks the total time the sensor has been running since manufacture
data type: 32-bit Record (subindex access not supported)
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit UInteger Run Counter Run Counter

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Resettable Run Time" index=70 id=V_ResettableRuntime

description: A run time counter that can be written by the user
data type: 32-bit Record (subindex access not supported)
access rights: rw
excluded from data storage

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit UInteger Run Counter Run Counter

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "AO1 Setpoints" index=74 id=V_AO1_Setpoints

description: The reference value used for analog output calculation
data type: 64-bit Record (subindex access not supported)
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit Integer Setpoint SP1 SP1 analog set point.
2 0 32-bit Integer Setpoint SP2 SP2 analog set point.

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "AO1 Configuration" index=75 id=V_AO1_Configuration

description: Configuration for Analog Output AO1
data type: 32-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 24 8-bit UInteger 0 = 4-20mA, 128 = 0-10V, 129 = 0.5-4.5V Output Type Output type and range information
2 16 8-bit UInteger 0 = Positive, 1 = Negative 0 Slope The slope of the analog output
3 8 8-bit UInteger 0 = Hold, 1 = Low, 2 = High 1 Loss of Signal Output value when no target is present
4 0 8-bit UInteger 0 = 1, 1 = 2, 2 = 4, 3 = 8, 4 = 16, 5 = 32, 6 = 64, 7 = 128 0 Average Analog averaging selection

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 2 3 4  
element bit 7 - 0 7 - 0 7 - 0 7 - 0  

Variable "All-time Run Time Event Time" index=76 id=V_AllTimeRuntimeEventTime

description: Running time when an event will be raised indicating that service is required. Set to 0 to disable raising event.
data type: 32-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit UInteger 0 Event Time Event indicating the corresponding configured running time has elapsed.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Resettable Run Time Event Time" index=77 id=V_ResettableRuntimeEventTime

description: Running time when an event will be raised indicating that service is required. Set to 0 to disable raising event.
data type: 32-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit UInteger 0 Event Time Event indicating the corresponding configured running time has elapsed.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Active Sensing Range" index=78 id=V_ActiveSensingRange

description: Range over which targets will be searched for.
data type: 64-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit Integer Active Sensing Range Near Near measurement limit of sensing range.
2 0 32-bit Integer Active Sensing Range Far Far measurement limit of sensing range.

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "MDC Descriptor" index=16512 id=V_MDCDescriptor

description: Measuring Data Channel Descriptor - refer to Smart Sensor Profile 2nd Ed.
data type: 88-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer Lower Limit Lower Limit
2 24 32-bit Integer Upper Limit Upper Limit
3 8 16-bit UInteger 1010 = m 1010 Unit Unit
4 0 8-bit Integer -3 Scale Scale

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Events

CodeTypeNameDescription
6200 (0x1838)ErrorEvent 1
6201 (0x1839)ErrorEvent 2
25376 (0x6320)ErrorParameter errorCheck datasheet and values
36000 (0x8ca0)WarningAll-time Run Time EventEvent indicating the corresponding configured running time has elapsed.
36001 (0x8ca1)WarningResettable Run Time EventEvent indicating the corresponding configured running time has elapsed.
36003 (0x8ca3)NotificationTeach Completed EventEvent indicating a teach has been completed.
36004 (0x8ca4)NotificationFactory Settings Restored EventEvent indicating that the factory settings have been restored.
36005 (0x8ca5)NotificationTeach Coerced EventEvent indicating a taught condition resulting in a setpoint being coerced. Taught was updated.
36007 (0x8ca7)NotificationTeach Failed EventEvent indicating an invalid target condition was attempted to be taught. Taught setpoint was not updated.
36096 (0x8d00)ErrorTransceiver Fault EventEvent indicating that an error has occurred with the radar transceiver.
36097 (0x8d01)ErrorSystem Fault EventContact Banner Engineering to resolve.

Operator Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_ApplicationSpecificTag

Parameters Menu
V_Configuration.Process Data Layout, ro

Observation Menu
If V_Configuration.Process Data Layout = 0:
Process Data
V_ProcessDataInput.5
V_ProcessDataInput.4
V_ProcessDataInput.3
V_ProcessDataInput.1 * 0.001 m
If V_Configuration.Process Data Layout = 1:
Process Data
V_ProcessDataInput.2 * 0.01
V_ProcessDataInput.1 * 0.001 m
If V_Configuration.Process Data Layout = 2:
Process Data
V_ProcessDataInput.5
V_ProcessDataInput.4
V_ProcessDataInput.3
V_ProcessDataInput.2
V_ProcessDataInput.1 * 0.001 m

Maintenance Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_HardwareRevision
V_ApplicationSpecificTag
V_CP_FunctionTag
V_CP_LocationTag

Parameters Menu
System Commands
V_SystemCommand, Button:=129
Description=The parameter of the technology-specific application are set to default values. Identification parameter remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master.
V_SystemCommand, Button:=131
Description=The parameter of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port!
V_SystemCommand, Button:=65
V_SystemCommand, Button:=66
Teach-in Channel
V_TeachInChannel
BDC1 Configuration
V_BDC1_Configuration.Switch point logic
V_BDC1_Configuration.BDC Mode
V_BDC1_Configuration.Hysteresis mm
BDC1 Setpoints
V_BDC1_Setpoints.Setpoint SP1 mm
V_BDC1_Setpoints.Setpoint SP2 mm
BDC1 Vendor Specific Configuration
V_BDC1_VendorConfiguration.Delay On ms
V_BDC1_VendorConfiguration.Delay Off ms
V_BDC1_VendorConfiguration.Teach Offset mm
AO1 Configuration
V_AO1_Configuration.Output Type
V_AO1_Configuration.Slope
V_AO1_Configuration.Loss of Signal
V_AO1_Configuration.Average
AO1 Setpoints
V_AO1_Setpoints.Setpoint SP1 mm
V_AO1_Setpoints.Setpoint SP2 mm
Active Sensing Range
V_ActiveSensingRange.Active Sensing Range Near mm
V_ActiveSensingRange.Active Sensing Range Far mm
Configuration
V_Configuration.Response Speed
V_Configuration.Peak Select Mode
V_Configuration.Output Polarity
V_Configuration.Process Data Filter Time ms
V_Configuration.Process Data Layout
V_Configuration.Remote Input Mode
V_Configuration.LEDs Disabled
V_Configuration.Amplitude Threshold * 0.01
V_Configuration.Limit Filter Enabled
V_Configuration.Limit Filter Positive Hold Time ms
V_Configuration.Limit Filter Negative Hold Time ms
V_Configuration.Limit Filter Positive Distance mm
V_Configuration.Limit Filter Negative Distance mm

Observation Menu
If V_Configuration.Process Data Layout = 0:
Process Data
V_ProcessDataInput.5
V_ProcessDataInput.4
V_ProcessDataInput.3
V_ProcessDataInput.1 * 0.001 m
If V_Configuration.Process Data Layout = 1:
Process Data
V_ProcessDataInput.2 * 0.01
V_ProcessDataInput.1 * 0.001 m
If V_Configuration.Process Data Layout = 2:
Process Data
V_ProcessDataInput.5
V_ProcessDataInput.4
V_ProcessDataInput.3
V_ProcessDataInput.2
V_ProcessDataInput.1 * 0.001 m

Diagnosis Menu
Service Functions
V_SystemCommand, Button:=126
Description=The visual indicators of the device are switched to the localization display pattern, which makes it easier to spot a device in an application.
V_SystemCommand, Button:=127
Description=The localization indication pattern is stopped. The optical indicators of the device will show again the device specific states of operation.
Device Status
V_DeviceStatus
V_DetailedDeviceStatus
All-time Run Time Counters
V_AllTimeRuntime.Run Counter * 0.25 h
V_AllTimeRuntimeEventTime.Event Time * 0.25 h
Resettable Run Time Counters
V_ResettableRuntime.Run Counter * 0.25 h
V_ResettableRuntimeEventTime.Event Time * 0.25 h
Teach-in Status
V_TeachStatus
Status
V_Status.Distance Measurement mm
V_Status.Excess Gain * 0.01
V_Status.Stability
V_Status.Fault Status
V_Status.Analog Output Value * 1E-05
V_Status.Temperature * 0.1 °C
V_Status.Last Taught Temperature * 0.1 °C
MDC Descriptor
V_MDCDescriptor.Lower Limit * 0.001 m
V_MDCDescriptor.Upper Limit * 0.001 m
V_MDCDescriptor.Unit
V_MDCDescriptor.Scale

Commissioning Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_HardwareRevision
V_ApplicationSpecificTag
V_CP_FunctionTag
V_CP_LocationTag

Parameters Menu
System Commands
V_SystemCommand, Button:=129
Description=The parameter of the technology-specific application are set to default values. Identification parameter remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master.
V_SystemCommand, Button:=131
Description=The parameter of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port!
V_SystemCommand, Button:=65
V_SystemCommand, Button:=66
Teach-in Channel
V_TeachInChannel
BDC1 Configuration
V_BDC1_Configuration.Switch point logic
V_BDC1_Configuration.BDC Mode
V_BDC1_Configuration.Hysteresis mm
BDC1 Setpoints
V_BDC1_Setpoints.Setpoint SP1 mm
V_BDC1_Setpoints.Setpoint SP2 mm
BDC1 Vendor Specific Configuration
V_BDC1_VendorConfiguration.Delay On ms
V_BDC1_VendorConfiguration.Delay Off ms
V_BDC1_VendorConfiguration.Teach Offset mm
AO1 Configuration
V_AO1_Configuration.Output Type
V_AO1_Configuration.Slope
V_AO1_Configuration.Loss of Signal
V_AO1_Configuration.Average
AO1 Setpoints
V_AO1_Setpoints.Setpoint SP1 mm
V_AO1_Setpoints.Setpoint SP2 mm
Active Sensing Range
V_ActiveSensingRange.Active Sensing Range Near mm
V_ActiveSensingRange.Active Sensing Range Far mm
Configuration
V_Configuration.Response Speed
V_Configuration.Peak Select Mode
V_Configuration.Output Polarity
V_Configuration.Process Data Filter Time ms
V_Configuration.Process Data Layout
V_Configuration.Remote Input Mode
V_Configuration.LEDs Disabled
V_Configuration.Amplitude Threshold * 0.01
V_Configuration.Limit Filter Enabled
V_Configuration.Limit Filter Positive Hold Time ms
V_Configuration.Limit Filter Negative Hold Time ms
V_Configuration.Limit Filter Positive Distance mm
V_Configuration.Limit Filter Negative Distance mm

Observation Menu
If V_Configuration.Process Data Layout = 0:
Process Data
V_ProcessDataInput.5
V_ProcessDataInput.4
V_ProcessDataInput.3
V_ProcessDataInput.1 * 0.001 m
If V_Configuration.Process Data Layout = 1:
Process Data
V_ProcessDataInput.2 * 0.01
V_ProcessDataInput.1 * 0.001 m
If V_Configuration.Process Data Layout = 2:
Process Data
V_ProcessDataInput.5
V_ProcessDataInput.4
V_ProcessDataInput.3
V_ProcessDataInput.2
V_ProcessDataInput.1 * 0.001 m

Diagnosis Menu
Service Functions
V_SystemCommand, Button:=126
Description=The visual indicators of the device are switched to the localization display pattern, which makes it easier to spot a device in an application.
V_SystemCommand, Button:=127
Description=The localization indication pattern is stopped. The optical indicators of the device will show again the device specific states of operation.
Device Status
V_DeviceStatus
V_DetailedDeviceStatus
All-time Run Time Counters
V_AllTimeRuntime.Run Counter * 0.25 h
V_AllTimeRuntimeEventTime.Event Time * 0.25 h
Resettable Run Time Counters
V_ResettableRuntime.Run Counter * 0.25 h
V_ResettableRuntimeEventTime.Event Time * 0.25 h
Teach-in Status
V_TeachStatus
Status
V_Status.Distance Measurement mm
V_Status.Excess Gain * 0.01
V_Status.Stability
V_Status.Fault Status
V_Status.Analog Output Value * 1E-05
V_Status.Temperature * 0.1 °C
V_Status.Last Taught Temperature * 0.1 °C
MDC Descriptor
V_MDCDescriptor.Lower Limit * 0.001 m
V_MDCDescriptor.Upper Limit * 0.001 m
V_MDCDescriptor.Unit
V_MDCDescriptor.Scale

Note: This page shows the content of an IODD file transformed into HTML format. In the case of disparity between this and the XML view, the content of the XML file takes precedence.