Version: V1.2Release Date: 2023-12-01


R95C
Vendor ID 451 (0x01c3) Vendor Logo
Vendor Name Banner Engineering Corporation
Vendor Text More Sensors. More Solutions.
Vendor URL www.bannerengineering.com/io-link
Device ID 659473 (0x0a1011)
DeviceFamily R95C Series
Features
Block Parameter yes
Data Storage yes
Profile Characteristic 0x4000 (Common Application Profile: ?Unknown?), 0x8000 (Function Class: Device Identification), 0x8003 (Function Class: Device Diagnosis)
Supported Access Locks Parameter: yes, Data Storage: yes, Local Parameterization: yes, Local User Interface: yes
Communication
IO-Link Revision V1.1
Transmission Rate38400 bit/s (COM2)
Minimum Cycle Time 3.3 ms
SIO Mode Supported yes
M-Sequence CapabilityPREOPERATE = TYPE_0 with 1 octet on-request data
OPERATE = TYPE_2_V with 1 octet on-request data
ISDU supported
Device Variant R95C-4B4UI-KQ
Description 8-Port-2-Channel-Discrete-and-Analog-In-Out Converter
Product ID R95C-4B4UI-KQ
Device Icon Device Icon
Device Symbol Device Symbol
Connection TypeM12-4 connector
- pin 1 brown; L+
- pin 2 white; Other
- pin 3 (light) blue; L-
- pin 4 black; C/Q

ProcessData id=PD_ProcessDataWithSignal (condition V_Vendor_Specific_Configuration.1 == 0)

ProcessDataIn "Process Data Input" id=PD_ProcessDataIn

bit length: 232
data type: 232-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = Inactive, true = Active Port1 Discrete1 Input State true (1) = Discrete1 Input Active. Note - even if Discrete1 is configured as an output, the active state will be reflected at the input
2 1 Boolean false = Inactive, true = Active Port1 Discrete2 Input State true (1) = Discrete2 Input Active. Note - even if Discrete2 is configured as an output, the active state will be reflected at the input
3 2 Boolean false = Inactive, true = Active Port2 Discrete1 Input State true (1) = Discrete1 Input Active. Note - even if Discrete1 is configured as an output, the active state will be reflected at the input
4 3 Boolean false = Inactive, true = Active Port2 Discrete2 Input State true (1) = Discrete2 Input Active. Note - even if Discrete2 is configured as an output, the active state will be reflected at the input
5 4 Boolean false = Inactive, true = Active Port3 Discrete1 Input State true (1) = Discrete1 Input Active. Note - even if Discrete1 is configured as an output, the active state will be reflected at the input
6 5 Boolean false = Inactive, true = Active Port3 Discrete2 Input State true (1) = Discrete2 Input Active. Note - even if Discrete2 is configured as an output, the active state will be reflected at the input
7 6 Boolean false = Inactive, true = Active Port4 Discrete1 Input State true (1) = Discrete1 Input Active. Note - even if Discrete1 is configured as an output, the active state will be reflected at the input
8 7 Boolean false = Inactive, true = Active Port4 Discrete2 Input State true (1) = Discrete2 Input Active. Note - even if Discrete2 is configured as an output, the active state will be reflected at the input
9 8 32-bit Integer Process Data Measurement 1 Process Data Measurement 1 Value
10 40 32-bit Integer Process Data Measurement 2 Process Data Measurement 2 Value
11 72 32-bit Integer Process Data Measurement 3 Process Data Measurement 3 Value
12 104 32-bit Integer Process Data Measurement 4 Process Data Measurement 4 Value
13 136 24-bit Integer Measurement Value - Analog in 1 If The Mode of Analog In = Voltage, Process Data Input = value*0.001V, If The Mode of Analog In = Current, Process Data Input = value*0.000001A
14 160 24-bit Integer Measurement Value - Analog in 2 If The Mode of Analog In = Voltage, Process Data Input = value*0.001V, If The Mode of Analog In = Current, Process Data Input = value*0.000001A
15 184 24-bit Integer Measurement Value - Analog in 3 If The Mode of Analog In = Voltage, Process Data Input = value*0.001V, If The Mode of Analog In = Current, Process Data Input = value*0.000001A
16 208 24-bit Integer Measurement Value - Analog in 4 If The Mode of Analog In = Voltage, Process Data Input = value*0.001V, If The Mode of Analog In = Current, Process Data Input = value*0.000001A
Octet 0
bit offset 231 230 229 228 227 226 225 224
subindex 16
element bit 23 22 21 20 19 18 17 16
Octet 1
bit offset 223 222 221 220 219 218 217 216
subindex 16
element bit 15 14 13 12 11 10 9 8
Octet 2
bit offset 215 214 213 212 211 210 209 208
subindex 16
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 207 206 205 204 203 202 201 200
subindex 15
element bit 23 22 21 20 19 18 17 16
Octet 4
bit offset 199 198 197 196 195 194 193 192
subindex 15
element bit 15 14 13 12 11 10 9 8
Octet 5
bit offset 191 190 189 188 187 186 185 184
subindex 15
element bit 7 6 5 4 3 2 1 0
Octet 6
bit offset 183 182 181 180 179 178 177 176
subindex 14
element bit 23 22 21 20 19 18 17 16
Octet 7
bit offset 175 174 173 172 171 170 169 168
subindex 14
element bit 15 14 13 12 11 10 9 8
Octet 8
bit offset 167 166 165 164 163 162 161 160
subindex 14
element bit 7 6 5 4 3 2 1 0
Octet 9
bit offset 159 158 157 156 155 154 153 152
subindex 13
element bit 23 22 21 20 19 18 17 16
Octet 10
bit offset 151 150 149 148 147 146 145 144
subindex 13
element bit 15 14 13 12 11 10 9 8
Octet 11
bit offset 143 142 141 140 139 138 137 136
subindex 13
element bit 7 6 5 4 3 2 1 0
Octet 12
bit offset 135 134 133 132 131 130 129 128
subindex 12
element bit 31 30 29 28 27 26 25 24
Octet 13
bit offset 127 126 125 124 123 122 121 120
subindex 12
element bit 23 22 21 20 19 18 17 16
Octet 14
bit offset 119 118 117 116 115 114 113 112
subindex 12
element bit 15 14 13 12 11 10 9 8
Octet 15
bit offset 111 110 109 108 107 106 105 104
subindex 12
element bit 7 6 5 4 3 2 1 0
Octet 16
bit offset 103 102 101 100 99 98 97 96
subindex 11
element bit 31 30 29 28 27 26 25 24
Octet 17
bit offset 95 94 93 92 91 90 89 88
subindex 11
element bit 23 22 21 20 19 18 17 16
Octet 18
bit offset 87 86 85 84 83 82 81 80
subindex 11
element bit 15 14 13 12 11 10 9 8
Octet 19
bit offset 79 78 77 76 75 74 73 72
subindex 11
element bit 7 6 5 4 3 2 1 0
Octet 20
bit offset 71 70 69 68 67 66 65 64
subindex 10
element bit 31 30 29 28 27 26 25 24
Octet 21
bit offset 63 62 61 60 59 58 57 56
subindex 10
element bit 23 22 21 20 19 18 17 16
Octet 22
bit offset 55 54 53 52 51 50 49 48
subindex 10
element bit 15 14 13 12 11 10 9 8
Octet 23
bit offset 47 46 45 44 43 42 41 40
subindex 10
element bit 7 6 5 4 3 2 1 0
Octet 24
bit offset 39 38 37 36 35 34 33 32
subindex 9
element bit 31 30 29 28 27 26 25 24
Octet 25
bit offset 31 30 29 28 27 26 25 24
subindex 9
element bit 23 22 21 20 19 18 17 16
Octet 26
bit offset 23 22 21 20 19 18 17 16
subindex 9
element bit 15 14 13 12 11 10 9 8
Octet 27
bit offset 15 14 13 12 11 10 9 8
subindex 9
element bit 7 6 5 4 3 2 1 0
Octet 28
bit offset 7 6 5 4 3 2 1 0
subindex 8 7 6 5 4 3 2 1

ProcessDataOut "Process Data Output" id=PD_ProcessDataOut

bit length: 72
data type: 72-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = Off, true = On Port1 Discrete1 Output State true (1) = Discrete1 Output Active
2 1 Boolean false = Off, true = On Port1 Discrete2 Output State true (1) = Discrete2 Output Active
3 2 Boolean false = Off, true = On Port2 Discrete1 Output State true (1) = Discrete1 Output Active
4 3 Boolean false = Off, true = On Port2 Discrete2 Output State true (1) = Discrete2 Output Active
5 4 Boolean false = Off, true = On Port3 Discrete1 Output State true (1) = Discrete1 Output Active
6 5 Boolean false = Off, true = On Port3 Discrete2 Output State true (1) = Discrete2 Output Active
7 6 Boolean false = Off, true = On Port4 Discrete1 Output State true (1) = Discrete1 Output Active
8 7 Boolean false = Off, true = On Port4 Discrete2 Output State true (1) = Discrete2 Output Active
9 8 16-bit Integer Analog Out Value 1 If Voltage = Enter mV value, If Current = Enter uA value
10 24 16-bit Integer Analog Out Value 2 If Voltage = Enter mV value, If Current = Enter uA value
11 40 16-bit Integer Analog Out Value 3 If Voltage = Enter mV value, If Current = Enter uA value
12 56 16-bit Integer Analog Out Value 4 If Voltage = Enter mV value, If Current = Enter uA value
Octet 0
bit offset 71 70 69 68 67 66 65 64
subindex 12
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 63 62 61 60 59 58 57 56
subindex 12
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 55 54 53 52 51 50 49 48
subindex 11
element bit 15 14 13 12 11 10 9 8
Octet 3
bit offset 47 46 45 44 43 42 41 40
subindex 11
element bit 7 6 5 4 3 2 1 0
Octet 4
bit offset 39 38 37 36 35 34 33 32
subindex 10
element bit 15 14 13 12 11 10 9 8
Octet 5
bit offset 31 30 29 28 27 26 25 24
subindex 10
element bit 7 6 5 4 3 2 1 0
Octet 6
bit offset 23 22 21 20 19 18 17 16
subindex 9
element bit 15 14 13 12 11 10 9 8
Octet 7
bit offset 15 14 13 12 11 10 9 8
subindex 9
element bit 7 6 5 4 3 2 1 0
Octet 8
bit offset 7 6 5 4 3 2 1 0
subindex 8 7 6 5 4 3 2 1

ProcessData id=PD_ProcessDataWithDMS (condition V_Vendor_Specific_Configuration.1 == 1)

ProcessDataIn "Process Data Input" id=PD_ProcessDataInDMS

bit length: 232
data type: 232-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = Inactive, true = Active Port1 Discrete1 Input State true (1) = Discrete1 Input Active. Note - even if Discrete1 is configured as an output, the active state will be reflected at the input
2 1 Boolean false = Inactive, true = Active Port1 Discrete2 Input State true (1) = Discrete2 Input Active. Note - even if Discrete2 is configured as an output, the active state will be reflected at the input
3 2 Boolean false = Inactive, true = Active Port2 Discrete1 Input State true (1) = Discrete1 Input Active. Note - even if Discrete1 is configured as an output, the active state will be reflected at the input
4 3 Boolean false = Inactive, true = Active Port2 Discrete2 Input State true (1) = Discrete2 Input Active. Note - even if Discrete2 is configured as an output, the active state will be reflected at the input
5 4 Boolean false = Inactive, true = Active Port3 Discrete1 Input State true (1) = Discrete1 Input Active. Note - even if Discrete1 is configured as an output, the active state will be reflected at the input
6 5 Boolean false = Inactive, true = Active Port3 Discrete2 Input State true (1) = Discrete2 Input Active. Note - even if Discrete2 is configured as an output, the active state will be reflected at the input
7 6 Boolean false = Inactive, true = Active Port4 Discrete1 Input State true (1) = Discrete1 Input Active. Note - even if Discrete1 is configured as an output, the active state will be reflected at the input
8 7 Boolean false = Inactive, true = Active Port4 Discrete2 Input State true (1) = Discrete2 Input Active. Note - even if Discrete2 is configured as an output, the active state will be reflected at the input
9 8 32-bit Integer Process Data Measurement 1 Process Data Measurement 1 Value
10 40 32-bit Integer Process Data Measurement 2 Process Data Measurement 2 Value
11 72 32-bit Integer Process Data Measurement 3 Process Data Measurement 3 Value
12 104 32-bit Integer Process Data Measurement 4 Process Data Measurement 4 Value
13 136 16-bit Integer Measurement Value 5 The channel 5 measurement device value
14 152 7-bit Integer Measurement Scale 5 The channel 5 measurement device scale
15 159 Boolean SSC5.1 - Switching Signal Indicates the detection status of an object or measurement value within a window.
16 160 16-bit Integer Measurement Value 6 The channel 6 measurement device value
17 176 7-bit Integer Measurement Scale 6 The channel 6 measurement device scale
18 183 Boolean SSC6.1 - Switching Signal Indicates the detection status of an object or measurement value within a window.
19 184 16-bit Integer Measurement Value 7 The channel 7 measurement device value
20 200 7-bit Integer Measurement Scale 7 The channel 7 measurement device scale
21 207 Boolean SSC7.1 - Switching Signal Indicates the detection status of an object or measurement value within a window.
22 208 16-bit Integer Measurement Value 8 The channel 8 measurement device value
23 224 7-bit Integer Measurement Scale 8 The channel 8 measurement device scale
24 231 Boolean SSC8.1 - Switching Signal Indicates the detection status of an object or measurement value within a window.
Octet 0
bit offset 231 230 229 228 227 226 225 224
subindex 24 23
element bit   6 5 4 3 2 1 0
Octet 1
bit offset 223 222 221 220 219 218 217 216
subindex 22
element bit 15 14 13 12 11 10 9 8
Octet 2
bit offset 215 214 213 212 211 210 209 208
subindex 22
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 207 206 205 204 203 202 201 200
subindex 21 20
element bit   6 5 4 3 2 1 0
Octet 4
bit offset 199 198 197 196 195 194 193 192
subindex 19
element bit 15 14 13 12 11 10 9 8
Octet 5
bit offset 191 190 189 188 187 186 185 184
subindex 19
element bit 7 6 5 4 3 2 1 0
Octet 6
bit offset 183 182 181 180 179 178 177 176
subindex 18 17
element bit   6 5 4 3 2 1 0
Octet 7
bit offset 175 174 173 172 171 170 169 168
subindex 16
element bit 15 14 13 12 11 10 9 8
Octet 8
bit offset 167 166 165 164 163 162 161 160
subindex 16
element bit 7 6 5 4 3 2 1 0
Octet 9
bit offset 159 158 157 156 155 154 153 152
subindex 15 14
element bit   6 5 4 3 2 1 0
Octet 10
bit offset 151 150 149 148 147 146 145 144
subindex 13
element bit 15 14 13 12 11 10 9 8
Octet 11
bit offset 143 142 141 140 139 138 137 136
subindex 13
element bit 7 6 5 4 3 2 1 0
Octet 12
bit offset 135 134 133 132 131 130 129 128
subindex 12
element bit 31 30 29 28 27 26 25 24
Octet 13
bit offset 127 126 125 124 123 122 121 120
subindex 12
element bit 23 22 21 20 19 18 17 16
Octet 14
bit offset 119 118 117 116 115 114 113 112
subindex 12
element bit 15 14 13 12 11 10 9 8
Octet 15
bit offset 111 110 109 108 107 106 105 104
subindex 12
element bit 7 6 5 4 3 2 1 0
Octet 16
bit offset 103 102 101 100 99 98 97 96
subindex 11
element bit 31 30 29 28 27 26 25 24
Octet 17
bit offset 95 94 93 92 91 90 89 88
subindex 11
element bit 23 22 21 20 19 18 17 16
Octet 18
bit offset 87 86 85 84 83 82 81 80
subindex 11
element bit 15 14 13 12 11 10 9 8
Octet 19
bit offset 79 78 77 76 75 74 73 72
subindex 11
element bit 7 6 5 4 3 2 1 0
Octet 20
bit offset 71 70 69 68 67 66 65 64
subindex 10
element bit 31 30 29 28 27 26 25 24
Octet 21
bit offset 63 62 61 60 59 58 57 56
subindex 10
element bit 23 22 21 20 19 18 17 16
Octet 22
bit offset 55 54 53 52 51 50 49 48
subindex 10
element bit 15 14 13 12 11 10 9 8
Octet 23
bit offset 47 46 45 44 43 42 41 40
subindex 10
element bit 7 6 5 4 3 2 1 0
Octet 24
bit offset 39 38 37 36 35 34 33 32
subindex 9
element bit 31 30 29 28 27 26 25 24
Octet 25
bit offset 31 30 29 28 27 26 25 24
subindex 9
element bit 23 22 21 20 19 18 17 16
Octet 26
bit offset 23 22 21 20 19 18 17 16
subindex 9
element bit 15 14 13 12 11 10 9 8
Octet 27
bit offset 15 14 13 12 11 10 9 8
subindex 9
element bit 7 6 5 4 3 2 1 0
Octet 28
bit offset 7 6 5 4 3 2 1 0
subindex 8 7 6 5 4 3 2 1

ProcessDataOut "Process Data Output" id=PD_ProcessDataOutDMS

bit length: 72
data type: 72-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = Off, true = On Port1 Discrete1 Output State true (1) = Discrete1 Output Active
2 1 Boolean false = Off, true = On Port1 Discrete2 Output State true (1) = Discrete2 Output Active
3 2 Boolean false = Off, true = On Port2 Discrete1 Output State true (1) = Discrete1 Output Active
4 3 Boolean false = Off, true = On Port2 Discrete2 Output State true (1) = Discrete2 Output Active
5 4 Boolean false = Off, true = On Port3 Discrete1 Output State true (1) = Discrete1 Output Active
6 5 Boolean false = Off, true = On Port3 Discrete2 Output State true (1) = Discrete2 Output Active
7 6 Boolean false = Off, true = On Port4 Discrete1 Output State true (1) = Discrete1 Output Active
8 7 Boolean false = Off, true = On Port4 Discrete2 Output State true (1) = Discrete2 Output Active
9 8 16-bit Integer Analog Out Value 1 If Voltage = Enter mV value, If Current = Enter uA value
10 24 16-bit Integer Analog Out Value 2 If Voltage = Enter mV value, If Current = Enter uA value
11 40 16-bit Integer Analog Out Value 3 If Voltage = Enter mV value, If Current = Enter uA value
12 56 16-bit Integer Analog Out Value 4 If Voltage = Enter mV value, If Current = Enter uA value
Octet 0
bit offset 71 70 69 68 67 66 65 64
subindex 12
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 63 62 61 60 59 58 57 56
subindex 12
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 55 54 53 52 51 50 49 48
subindex 11
element bit 15 14 13 12 11 10 9 8
Octet 3
bit offset 47 46 45 44 43 42 41 40
subindex 11
element bit 7 6 5 4 3 2 1 0
Octet 4
bit offset 39 38 37 36 35 34 33 32
subindex 10
element bit 15 14 13 12 11 10 9 8
Octet 5
bit offset 31 30 29 28 27 26 25 24
subindex 10
element bit 7 6 5 4 3 2 1 0
Octet 6
bit offset 23 22 21 20 19 18 17 16
subindex 9
element bit 15 14 13 12 11 10 9 8
Octet 7
bit offset 15 14 13 12 11 10 9 8
subindex 9
element bit 7 6 5 4 3 2 1 0
Octet 8
bit offset 7 6 5 4 3 2 1 0
subindex 8 7 6 5 4 3 2 1

Standard Variable "Direct Parameters 1" index=0 id=V_DirectParameters_1

data type: 128-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger ro Reserved
2 112 8-bit UInteger ro Master Cycle Time
3 104 8-bit UInteger ro Min Cycle Time
4 96 8-bit UInteger ro M-Sequence Capability
5 88 8-bit UInteger 17 ro IO-Link Version ID
6 80 8-bit UInteger ro Process Data Input Length
7 72 8-bit UInteger ro Process Data Output Length
8 64 8-bit UInteger ro Vendor ID 1
9 56 8-bit UInteger ro Vendor ID 2
10 48 8-bit UInteger ro Device ID 1
11 40 8-bit UInteger ro Device ID 2
12 32 8-bit UInteger ro Device ID 3
13 24 8-bit UInteger ro Reserved
14 16 8-bit UInteger ro Reserved
15 8 8-bit UInteger ro Reserved
16 0 8-bit UInteger 130 = Restore Factory Settings, 162 = Discovery Start, 163 = Discovery Stop, 164 = Reset All Metrics wo X Standard Command

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "Direct Parameters 2" index=1 id=V_DirectParameters_2

data type: 128-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger Device Specific Parameter 1
2 112 8-bit UInteger Device Specific Parameter 2
3 104 8-bit UInteger Device Specific Parameter 3
4 96 8-bit UInteger Device Specific Parameter 4
5 88 8-bit UInteger Device Specific Parameter 5
6 80 8-bit UInteger Device Specific Parameter 6
7 72 8-bit UInteger Device Specific Parameter 7
8 64 8-bit UInteger Device Specific Parameter 8
9 56 8-bit UInteger Device Specific Parameter 9
10 48 8-bit UInteger Device Specific Parameter 10
11 40 8-bit UInteger Device Specific Parameter 11
12 32 8-bit UInteger Device Specific Parameter 12
13 24 8-bit UInteger Device Specific Parameter 13
14 16 8-bit UInteger Device Specific Parameter 14
15 8 8-bit UInteger Device Specific Parameter 15
16 0 8-bit UInteger Device Specific Parameter 16

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "Standard Command" index=2 id=V_SystemCommand

data type: 8-bit UInteger
allowed values: 130 = Restore Factory Settings, 162 = Discovery Start, 163 = Discovery Stop, 164 = Reset All Metrics
access rights: wo
modifies other variables

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Device Access Locks" index=12 id=V_DeviceAccessLocks

data type: 16-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean Parameter (write) Access Lock
2 1 Boolean Data Storage Lock
3 2 Boolean false Local Parameterization Lock
4 3 Boolean false Local User Interface Lock
Octet 0
bit offset 15 14 13 12 11 10 9 8
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 1
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4 3 2 1

Standard Variable "Vendor Name" index=16 id=V_VendorName

data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Vendor Text" index=17 id=V_VendorText

data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product Name" index=18 id=V_ProductName

data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product ID" index=19 id=V_ProductID

data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product Text" index=20 id=V_ProductText

data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Serial Number" index=21 id=V_SerialNumber

data type: 16-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Firmware Version" index=23 id=V_FirmwareRevision

data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Application Specific Tag" index=24 id=V_ApplicationSpecificTag

data type: 32-octet String UTF-8
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Device Status" index=36 id=V_DeviceStatus

data type: 8-bit UInteger
allowed values: 0 = Device is OK, 1 = Maintenance required, 2 = Out of specification, 3 = Functional check, 4 = Failure, 5..255 = Reserved
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Detailed Device Status" index=37 id=V_DetailedDeviceStatus

data type: Array[6] of 3-octet OctetString (subindex access not supported)
access rights: ro
dynamic

octet 0 1 2 3 4 5 6 7
bit offset 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80
subindex 1 1 1 2 2 2 3 3

octet 8 9 10 11 12 13 14 15
bit offset 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16
subindex 3 4 4 4 5 5 5 6

octet 16 17  
bit offset 15 - 8 7 - 0  
subindex 6 6  

Standard Variable "Process Data Input" index=40 id=V_ProcessDataInput

data type: see ProcessDataIn!
access rights: ro
dynamic

Standard Variable "Process Data Output" index=41 id=V_ProcessDataOutput

data type: see ProcessDataOut!
access rights: ro
dynamic

Variable "Port 5 Mirroring Configuration" index=64 id=V_Port_Mirroring_Configuration_5

description: Port mirroring configuration options.
data type: 16-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = Disabled, 1 = Enabled 0 Mirroring Output Enable Enable mirroring over output analog channel.
2 8 8-bit UInteger 0 = Port5, 1 = Port6, 2 = Port7, 3 = Port8 0 Mirroring Input Port Selection Input port to mirror over output analog channel.

octet 0 1  
bit offset 15 - 8 7 - 0  
subindex 2 1  
element bit 7 - 0 7 - 0  

Variable "Port 6 Mirroring Configuration" index=65 id=V_Port_Mirroring_Configuration_6

description: Port mirroring configuration options.
data type: 16-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = Disabled, 1 = Enabled 0 Mirroring Output Enable Enable mirroring over output analog channel.
2 8 8-bit UInteger 0 = Port5, 1 = Port6, 2 = Port7, 3 = Port8 0 Mirroring Input Port Selection Input port to mirror over output analog channel.

octet 0 1  
bit offset 15 - 8 7 - 0  
subindex 2 1  
element bit 7 - 0 7 - 0  

Variable "Port 7 Mirroring Configuration" index=66 id=V_Port_Mirroring_Configuration_7

description: Port mirroring configuration options.
data type: 16-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = Disabled, 1 = Enabled 0 Mirroring Output Enable Enable mirroring over output analog channel.
2 8 8-bit UInteger 0 = Port5, 1 = Port6, 2 = Port7, 3 = Port8 0 Mirroring Input Port Selection Input port to mirror over output analog channel.

octet 0 1  
bit offset 15 - 8 7 - 0  
subindex 2 1  
element bit 7 - 0 7 - 0  

Variable "Port 8 Mirroring Configuration" index=67 id=V_Port_Mirroring_Configuration_8

description: Port mirroring configuration options.
data type: 16-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = Disabled, 1 = Enabled 0 Mirroring Output Enable Enable mirroring over output analog channel.
2 8 8-bit UInteger 0 = Port5, 1 = Port6, 2 = Port7, 3 = Port8 0 Mirroring Input Port Selection Input port to mirror over output analog channel.

octet 0 1  
bit offset 15 - 8 7 - 0  
subindex 2 1  
element bit 7 - 0 7 - 0  

Variable "All-time Run Time" index=69 id=V_AllTimeRunTime

description: A read only run time counter (in hours) that tracks the total time the sensor has been running since manufacture
data type: 32-bit Record (subindex access not supported)
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0..2147483647 Run counter Run counter

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Resetable Run Time" index=70 id=V_ResetableRunTime

description: A read / write run time counter (in hours) that can be monitored or set by the user
data type: 32-bit Record (subindex access not supported)
access rights: rw
excluded from data storage

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0..2147483647 Run counter Run counter

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Vendor Specific Configuration" index=76 id=V_Vendor_Specific_Configuration

description: Vendor Specific Configuration
data type: 216-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = Analog Value, 1 = Digital Measuring Sensor 0 Process Data Input Configuration The available Process Data Input Data Map Selections
2 8 8-bit UInteger 0 = Disabled, 1 = Count, 2 = Duration, 3 = Events Per Minute 1 Measurement 1 Metric Selection The Measurement Metric for PDI Measurement 1
3 16 8-bit UInteger 0 = Port1, 1 = Port2, 2 = Port3, 3 = Port4 0 Measurement 1 Port Selection The Port Selected for PDI Measurement 1
4 24 8-bit UInteger 0 = Discrete1, 1 = Discrete2 0 Measurement 1 Channel Selection The Channel Selected for PDI Measurement 1
5 32 8-bit UInteger 0 = Disabled, 1 = Count, 2 = Duration, 3 = Events Per Minute 1 Measurement 2 Metric Selection The Measurement Metric for PDI Measurement 2
6 40 8-bit UInteger 0 = Port1, 1 = Port2, 2 = Port3, 3 = Port4 1 Measurement 2 Port Selection The Port Selected for PDI Measurement 2
7 48 8-bit UInteger 0 = Discrete1, 1 = Discrete2 0 Measurement 2 Channel Selection The Channel Selected for PDI Measurement 2
8 56 8-bit UInteger 0 = Disabled, 1 = Count, 2 = Duration, 3 = Events Per Minute 1 Measurement 3 Metric Selection The Measurement Metric for PDI Measurement 3
9 64 8-bit UInteger 0 = Port1, 1 = Port2, 2 = Port3, 3 = Port4 2 Measurement 3 Port Selection The Port Selected for PDI Measurement 3
10 72 8-bit UInteger 0 = Discrete1, 1 = Discrete2 0 Measurement 3 Channel Selection The Channel Selected for PDI Measurement 3
11 80 8-bit UInteger 0 = Disabled, 1 = Count, 2 = Duration, 3 = Events Per Minute 1 Measurement 4 Metric Selection The Measurement Metric for PDI Measurement 4
12 88 8-bit UInteger 0 = Port1, 1 = Port2, 2 = Port3, 3 = Port4 3 Measurement 4 Port Selection The Port Selected for PDI Measurement 4
13 96 8-bit UInteger 0 = Discrete1, 1 = Discrete2 0 Measurement 4 Channel Selection The Channel Selected for PDI Measurement 4
14 104 8-bit UInteger 0 = Hold, 1 = Low, 2 = High 1 POVR1 -Process Data Out 5 Outside Valid Range Value sensor will output when PDO value is not within the allowable range
15 112 8-bit UInteger 0 = Hold, 1 = Low, 2 = High 1 POVR1 -Process Data Out 6 Outside Valid Range Value sensor will output when PDO value is not within the allowable range
16 120 8-bit UInteger 0 = Hold, 1 = Low, 2 = High 1 POVR1 -Process Data Out 7 Outside Valid Range Value sensor will output when PDO value is not within the allowable range
17 128 8-bit UInteger 0 = Hold, 1 = Low, 2 = High 1 POVR1 -Process Data Out 8 Outside Valid Range Value sensor will output when PDO value is not within the allowable range
18 136 16-bit UInteger 200 IOL Filter Time Time to average IOL process data measurement between updates.
19 152 8-bit UInteger 0 = Voltage, 1 = Current 1 Port 5 - The Mode of Analog In Analog Input selection of voltage or current
20 160 8-bit UInteger 0 = Voltage, 1 = Current 1 Port 6 - The Mode of Analog In Analog Input selection of voltage or current
21 168 8-bit UInteger 0 = Voltage, 1 = Current 1 Port 7 - The Mode of Analog In Analog Input selection of voltage or current
22 176 8-bit UInteger 0 = Voltage, 1 = Current 1 Port 8 - The Mode of Analog In Analog Input selection of voltage or current
23 184 8-bit UInteger 0 = Voltage, 1 = Current 1 Port 5 - Analog Output Mode Analog Output selection of voltage or current
24 192 8-bit UInteger 0 = Voltage, 1 = Current 1 Port 6 - Analog Output Mode Analog Output selection of voltage or current
25 200 8-bit UInteger 0 = Voltage, 1 = Current 1 Port 7 - Analog Output Mode Analog Output selection of voltage or current
26 208 8-bit UInteger 0 = Voltage, 1 = Current 1 Port 8 - Analog Output Mode Analog Output selection of voltage or current

octet 0 1 2 3 4 5 6 7
bit offset 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152
subindex 26 25 24 23 22 21 20 19
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88
subindex 18 18 17 16 15 14 13 12
element bit 15 - 8 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 11 10 9 8 7 6 5 4
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 24 25 26  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 2 1  
element bit 7 - 0 7 - 0 7 - 0  

Variable "All-time Run Time Event Time" index=78 id=V_AllTimeRunTimeEventTime

description: Running time when an event will be raised indicating that service is required. Set to 0 to disable raising event.
data type: 32-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0..2147483647 0 Event Time Event indicating the corresponding configured running time has elapsed.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Resetable Run Time Event Time" index=79 id=V_ResetableRunTimeEventTime

description: Running time when an event will be raised indicating that service is required. Set to 0 to disable raising event.
data type: 32-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0..2147483647 0 Event Time Running time when an event will be raised indicating that service is required. Set to 0 to disable raising event.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "IO Metrics Ports 1 to 4" index=80 id=V_IO_Metrics_Ports_1_to_4

description: IO Metrics Ports 1 to 4
data type: 1024-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer Port1 Discrete1 Count
2 32 32-bit Integer Port1 Discrete1 Duration
3 64 32-bit Integer Port1 Discrete1 Events Per Minute
4 96 32-bit Integer Port1 Discrete1 Totalizer Counter
5 128 32-bit Integer Port1 Discrete2 Count
6 160 32-bit Integer Port1 Discrete2 Duration
7 192 32-bit Integer Port1 Discrete2 Events Per Minute
8 224 32-bit Integer Port1 Discrete2 Totalizer Counter
9 256 32-bit Integer Port2 Discrete1 Count
10 288 32-bit Integer Port2 Discrete1 Duration
11 320 32-bit Integer Port2 Discrete1 Events Per Minute
12 352 32-bit Integer Port2 Discrete1 Totalizer Counter
13 384 32-bit Integer Port2 Discrete2 Count
14 416 32-bit Integer Port2 Discrete2 Duration
15 448 32-bit Integer Port2 Discrete2 Events Per Minute
16 480 32-bit Integer Port2 Discrete2 Totalizer Counter
17 512 32-bit Integer Port3 Discrete1 Count
18 544 32-bit Integer Port3 Discrete1 Duration
19 576 32-bit Integer Port3 Discrete1 Events Per Minute
20 608 32-bit Integer Port3 Discrete1 Totalizer Counter
21 640 32-bit Integer Port3 Discrete2 Count
22 672 32-bit Integer Port3 Discrete2 Duration
23 704 32-bit Integer Port3 Discrete2 Events Per Minute
24 736 32-bit Integer Port3 Discrete2 Totalizer Counter
25 768 32-bit Integer Port4 Discrete1 Count
26 800 32-bit Integer Port4 Discrete1 Duration
27 832 32-bit Integer Port4 Discrete1 Events Per Minute
28 864 32-bit Integer Port4 Discrete1 Totalizer Counter
29 896 32-bit Integer Port4 Discrete2 Count
30 928 32-bit Integer Port4 Discrete2 Duration
31 960 32-bit Integer Port4 Discrete2 Events Per Minute
32 992 32-bit Integer Port4 Discrete2 Totalizer Counter

octet 0 1 2 3 4 5 6 7
bit offset 1023 - 1016 1015 - 1008 1007 - 1000 999 - 992 991 - 984 983 - 976 975 - 968 967 - 960
subindex 32 32 32 32 31 31 31 31
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 959 - 952 951 - 944 943 - 936 935 - 928 927 - 920 919 - 912 911 - 904 903 - 896
subindex 30 30 30 30 29 29 29 29
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 895 - 888 887 - 880 879 - 872 871 - 864 863 - 856 855 - 848 847 - 840 839 - 832
subindex 28 28 28 28 27 27 27 27
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 24 25 26 27 28 29 30 31
bit offset 831 - 824 823 - 816 815 - 808 807 - 800 799 - 792 791 - 784 783 - 776 775 - 768
subindex 26 26 26 26 25 25 25 25
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 32 33 34 35 36 37 38 39
bit offset 767 - 760 759 - 752 751 - 744 743 - 736 735 - 728 727 - 720 719 - 712 711 - 704
subindex 24 24 24 24 23 23 23 23
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 40 41 42 43 44 45 46 47
bit offset 703 - 696 695 - 688 687 - 680 679 - 672 671 - 664 663 - 656 655 - 648 647 - 640
subindex 22 22 22 22 21 21 21 21
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 48 49 50 51 52 53 54 55
bit offset 639 - 632 631 - 624 623 - 616 615 - 608 607 - 600 599 - 592 591 - 584 583 - 576
subindex 20 20 20 20 19 19 19 19
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 56 57 58 59 60 61 62 63
bit offset 575 - 568 567 - 560 559 - 552 551 - 544 543 - 536 535 - 528 527 - 520 519 - 512
subindex 18 18 18 18 17 17 17 17
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 64 65 66 67 68 69 70 71
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448
subindex 16 16 16 16 15 15 15 15
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 72 73 74 75 76 77 78 79
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384
subindex 14 14 14 14 13 13 13 13
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 80 81 82 83 84 85 86 87
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320
subindex 12 12 12 12 11 11 11 11
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 88 89 90 91 92 93 94 95
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256
subindex 10 10 10 10 9 9 9 9
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 96 97 98 99 100 101 102 103
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192
subindex 8 8 8 8 7 7 7 7
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 104 105 106 107 108 109 110 111
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 6 6 6 6 5 5 5 5
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 112 113 114 115 116 117 118 119
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 4 4 4 4 3 3 3 3
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 120 121 122 123 124 125 126 127
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 2 2 2 2 1 1 1 1
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Selectable Metric Reset" index=82 id=V_Selectable_Metric_Reset

description: User can select which channel / Channels to reset
data type: 264-bit Record (subindex access not supported)
access rights: rw
excluded from data storage

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = Do Not Reset, true = Reset false Port1 Discrete1 If set to [Reset], Discrete1 metrics will be reset. Note - the Count value can be set to a non-zero value using [Port# Discrete1 Reset Count]
2 1 Boolean false = Do Not Reset, true = Reset false Port1 Discrete2 If set to [Reset], Discrete2 metrics will be reset. Note - the Count value can be set to a non-zero value using [Port# Discrete2 Reset Count]
3 2 Boolean false = Do Not Reset, true = Reset false Port2 Discrete1 If set to [Reset], Discrete1 metrics will be reset. Note - the Count value can be set to a non-zero value using [Port# Discrete1 Reset Count]
4 3 Boolean false = Do Not Reset, true = Reset false Port2 Discrete2 If set to [Reset], Discrete2 metrics will be reset. Note - the Count value can be set to a non-zero value using [Port# Discrete2 Reset Count]
5 4 Boolean false = Do Not Reset, true = Reset false Port3 Discrete1 If set to [Reset], Discrete1 metrics will be reset. Note - the Count value can be set to a non-zero value using [Port# Discrete1 Reset Count]
6 5 Boolean false = Do Not Reset, true = Reset false Port3 Discrete2 If set to [Reset], Discrete2 metrics will be reset. Note - the Count value can be set to a non-zero value using [Port# Discrete2 Reset Count]
7 6 Boolean false = Do Not Reset, true = Reset false Port4 Discrete1 If set to [Reset], Discrete1 metrics will be reset. Note - the Count value can be set to a non-zero value using [Port# Discrete1 Reset Count]
8 7 Boolean false = Do Not Reset, true = Reset false Port4 Discrete2 If set to [Reset], Discrete2 metrics will be reset. Note - the Count value can be set to a non-zero value using [Port# Discrete2 Reset Count]
9 8 32-bit Integer 0..2147483647 0 Port1 Discrete1 Reset Count
10 40 32-bit Integer 0..2147483647 0 Port1 Discrete2 Reset Count
11 72 32-bit Integer 0..2147483647 0 Port2 Discrete1 Reset Count
12 104 32-bit Integer 0..2147483647 0 Port2 Discrete2 Reset Count
13 136 32-bit Integer 0..2147483647 0 Port3 Discrete1 Reset Count
14 168 32-bit Integer 0..2147483647 0 Port3 Discrete2 Reset Count
15 200 32-bit Integer 0..2147483647 0 Port4 Discrete1 Reset Count
16 232 32-bit Integer 0..2147483647 0 Port4 Discrete2 Reset Count
Octet 0
bit offset 263 262 261 260 259 258 257 256
subindex 16
element bit 31 30 29 28 27 26 25 24
Octet 1
bit offset 255 254 253 252 251 250 249 248
subindex 16
element bit 23 22 21 20 19 18 17 16
Octet 2
bit offset 247 246 245 244 243 242 241 240
subindex 16
element bit 15 14 13 12 11 10 9 8
Octet 3
bit offset 239 238 237 236 235 234 233 232
subindex 16
element bit 7 6 5 4 3 2 1 0
Octet 4
bit offset 231 230 229 228 227 226 225 224
subindex 15
element bit 31 30 29 28 27 26 25 24
Octet 5
bit offset 223 222 221 220 219 218 217 216
subindex 15
element bit 23 22 21 20 19 18 17 16
Octet 6
bit offset 215 214 213 212 211 210 209 208
subindex 15
element bit 15 14 13 12 11 10 9 8
Octet 7
bit offset 207 206 205 204 203 202 201 200
subindex 15
element bit 7 6 5 4 3 2 1 0
Octet 8
bit offset 199 198 197 196 195 194 193 192
subindex 14
element bit 31 30 29 28 27 26 25 24
Octet 9
bit offset 191 190 189 188 187 186 185 184
subindex 14
element bit 23 22 21 20 19 18 17 16
Octet 10
bit offset 183 182 181 180 179 178 177 176
subindex 14
element bit 15 14 13 12 11 10 9 8
Octet 11
bit offset 175 174 173 172 171 170 169 168
subindex 14
element bit 7 6 5 4 3 2 1 0
Octet 12
bit offset 167 166 165 164 163 162 161 160
subindex 13
element bit 31 30 29 28 27 26 25 24
Octet 13
bit offset 159 158 157 156 155 154 153 152
subindex 13
element bit 23 22 21 20 19 18 17 16
Octet 14
bit offset 151 150 149 148 147 146 145 144
subindex 13
element bit 15 14 13 12 11 10 9 8
Octet 15
bit offset 143 142 141 140 139 138 137 136
subindex 13
element bit 7 6 5 4 3 2 1 0
Octet 16
bit offset 135 134 133 132 131 130 129 128
subindex 12
element bit 31 30 29 28 27 26 25 24
Octet 17
bit offset 127 126 125 124 123 122 121 120
subindex 12
element bit 23 22 21 20 19 18 17 16
Octet 18
bit offset 119 118 117 116 115 114 113 112
subindex 12
element bit 15 14 13 12 11 10 9 8
Octet 19
bit offset 111 110 109 108 107 106 105 104
subindex 12
element bit 7 6 5 4 3 2 1 0
Octet 20
bit offset 103 102 101 100 99 98 97 96
subindex 11
element bit 31 30 29 28 27 26 25 24
Octet 21
bit offset 95 94 93 92 91 90 89 88
subindex 11
element bit 23 22 21 20 19 18 17 16
Octet 22
bit offset 87 86 85 84 83 82 81 80
subindex 11
element bit 15 14 13 12 11 10 9 8
Octet 23
bit offset 79 78 77 76 75 74 73 72
subindex 11
element bit 7 6 5 4 3 2 1 0
Octet 24
bit offset 71 70 69 68 67 66 65 64
subindex 10
element bit 31 30 29 28 27 26 25 24
Octet 25
bit offset 63 62 61 60 59 58 57 56
subindex 10
element bit 23 22 21 20 19 18 17 16
Octet 26
bit offset 55 54 53 52 51 50 49 48
subindex 10
element bit 15 14 13 12 11 10 9 8
Octet 27
bit offset 47 46 45 44 43 42 41 40
subindex 10
element bit 7 6 5 4 3 2 1 0
Octet 28
bit offset 39 38 37 36 35 34 33 32
subindex 9
element bit 31 30 29 28 27 26 25 24
Octet 29
bit offset 31 30 29 28 27 26 25 24
subindex 9
element bit 23 22 21 20 19 18 17 16
Octet 30
bit offset 23 22 21 20 19 18 17 16
subindex 9
element bit 15 14 13 12 11 10 9 8
Octet 31
bit offset 15 14 13 12 11 10 9 8
subindex 9
element bit 7 6 5 4 3 2 1 0
Octet 32
bit offset 7 6 5 4 3 2 1 0
subindex 8 7 6 5 4 3 2 1

Variable "Port1 Configuration" index=87 id=V_Port1_Configuration

description: Port1 Configuration
data type: 352-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = NPN Input, 1 = PNP Input, 2 = NPN Output with Pull Up, 3 = PNP Output with Pull Down, 4 = NPN Output Push Pull, 5 = PNP Output Push Pull 3 Discrete1 IO Selection
2 8 8-bit UInteger 0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3 = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On One-shot, 8 = Retriggerable Off One-shot 0 Discrete1 Delay Mode Discrete1 Delay Mode Selection
3 16 32-bit Integer 0 Discrete1 Delay Timer 1 Discrete1 On Delay, One-shot, Pulse-stretcher time or Totalizer Count
4 48 32-bit Integer 0 Discrete1 Delay Timer 2 Discrete1 Off Delay or Totalizer time.
5 80 8-bit UInteger 0 = Disabled, 1 = Enabled 0 Discrete1 Mirroring Enable
6 88 8-bit UInteger 0 = Port1, 1 = Port2, 2 = Port3, 3 = Port4, 4 = Port5, 5 = Port6, 6 = Port7, 7 = Port8 0 Discrete1 Mirroring Port Selection
7 96 8-bit UInteger 0 = Discrete1, 1 = Discrete2 0 Discrete1 Mirroring Channel Selection
8 104 8-bit UInteger 0 = Not Inverted, 1 = Inverted 0 Discrete1 Mirroring Inversion
9 112 32-bit Integer 100..600 100 Discrete1 PFM Near Frequency (Hz) The frequency corresponding to a target at the near limit of the sensing range
10 144 32-bit Integer 100..600 600 Discrete1 PFM Far Frequency (Hz) The frequency corresponding to a target at the far limit of the sensing range
11 176 8-bit UInteger 0 = NPN Input, 1 = PNP Input, 2 = NPN Output with Pull Up, 3 = PNP Output with Pull Down, 4 = NPN Output Push Pull, 5 = PNP Output Push Pull 3 Discrete2 IO Selection
12 184 8-bit UInteger 0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3 = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On One-shot, 8 = Retriggerable Off One-shot 0 Discrete2 Delay Mode Discrete2 Delay Mode Selection
13 192 32-bit Integer 0 Discrete2 Delay Timer 1 Discrete2 On Delay, One-shot, Pulse-stretcher time or Totalizer Count
14 224 32-bit Integer 0 Discrete2 Delay Timer 2 Discrete2 Off Delay or Totalizer time
15 256 8-bit UInteger 0 = Disabled, 1 = Enabled 0 Discrete2 Mirroring Enable
16 264 8-bit UInteger 0 = Port1, 1 = Port2, 2 = Port3, 3 = Port4, 4 = Port5, 5 = Port6, 6 = Port7, 7 = Port8 0 Discrete2 Mirroring Port Selection
17 272 8-bit UInteger 0 = Discrete1, 1 = Discrete2 0 Discrete2 Mirroring Channel Selection
18 280 8-bit UInteger 0 = Not Inverted, 1 = Inverted 0 Discrete2 Mirroring Inversion
19 288 32-bit Integer 100..600 100 Discrete2 PFM Near Frequency (Hz) The frequency corresponding to a target at the near limit of the sensing range
20 320 32-bit Integer 100..600 600 Discrete2 PFM Far Frequency (Hz) The frequency corresponding to a target at the far limit of the sensing range

octet 0 1 2 3 4 5 6 7
bit offset 351 - 344 343 - 336 335 - 328 327 - 320 319 - 312 311 - 304 303 - 296 295 - 288
subindex 20 20 20 20 19 19 19 19
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 287 - 280 279 - 272 271 - 264 263 - 256 255 - 248 247 - 240 239 - 232 231 - 224
subindex 18 17 16 15 14 14 14 14
element bit 7 - 0 7 - 0 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 223 - 216 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176 175 - 168 167 - 160
subindex 13 13 13 13 12 11 10 10
element bit 31 - 24 23 - 16 15 - 8 7 - 0 7 - 0 7 - 0 31 - 24 23 - 16

octet 24 25 26 27 28 29 30 31
bit offset 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96
subindex 10 10 9 9 9 9 8 7
element bit 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 7 - 0 7 - 0

octet 32 33 34 35 36 37 38 39
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32
subindex 6 5 4 4 4 4 3 3
element bit 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16

octet 40 41 42 43  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 3 3 2 1  
element bit 15 - 8 7 - 0 7 - 0 7 - 0  

Variable "Port2 Configuration" index=88 id=V_Port2_Configuration

description: Port2 Configuration
data type: 352-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = NPN Input, 1 = PNP Input, 2 = NPN Output with Pull Up, 3 = PNP Output with Pull Down, 4 = NPN Output Push Pull, 5 = PNP Output Push Pull 3 Discrete1 IO Selection
2 8 8-bit UInteger 0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3 = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On One-shot, 8 = Retriggerable Off One-shot 0 Discrete1 Delay Mode Discrete1 Delay Mode Selection
3 16 32-bit Integer 0 Discrete1 Delay Timer 1 Discrete1 On Delay, One-shot, Pulse-stretcher time or Totalizer Count
4 48 32-bit Integer 0 Discrete1 Delay Timer 2 Discrete1 Off Delay or Totalizer time.
5 80 8-bit UInteger 0 = Disabled, 1 = Enabled 0 Discrete1 Mirroring Enable
6 88 8-bit UInteger 0 = Port1, 1 = Port2, 2 = Port3, 3 = Port4, 4 = Port5, 5 = Port6, 6 = Port7, 7 = Port8 0 Discrete1 Mirroring Port Selection
7 96 8-bit UInteger 0 = Discrete1, 1 = Discrete2 0 Discrete1 Mirroring Channel Selection
8 104 8-bit UInteger 0 = Not Inverted, 1 = Inverted 0 Discrete1 Mirroring Inversion
9 112 32-bit Integer 100..600 100 Discrete1 PFM Near Frequency (Hz) The frequency corresponding to a target at the near limit of the sensing range
10 144 32-bit Integer 100..600 600 Discrete1 PFM Far Frequency (Hz) The frequency corresponding to a target at the far limit of the sensing range
11 176 8-bit UInteger 0 = NPN Input, 1 = PNP Input, 2 = NPN Output with Pull Up, 3 = PNP Output with Pull Down, 4 = NPN Output Push Pull, 5 = PNP Output Push Pull 3 Discrete2 IO Selection
12 184 8-bit UInteger 0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3 = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On One-shot, 8 = Retriggerable Off One-shot 0 Discrete2 Delay Mode Discrete2 Delay Mode Selection
13 192 32-bit Integer 0 Discrete2 Delay Timer 1 Discrete2 On Delay, One-shot, Pulse-stretcher time or Totalizer Count
14 224 32-bit Integer 0 Discrete2 Delay Timer 2 Discrete2 Off Delay or Totalizer time
15 256 8-bit UInteger 0 = Disabled, 1 = Enabled 0 Discrete2 Mirroring Enable
16 264 8-bit UInteger 0 = Port1, 1 = Port2, 2 = Port3, 3 = Port4, 4 = Port5, 5 = Port6, 6 = Port7, 7 = Port8 0 Discrete2 Mirroring Port Selection
17 272 8-bit UInteger 0 = Discrete1, 1 = Discrete2 0 Discrete2 Mirroring Channel Selection
18 280 8-bit UInteger 0 = Not Inverted, 1 = Inverted 0 Discrete2 Mirroring Inversion
19 288 32-bit Integer 100..600 100 Discrete2 PFM Near Frequency (Hz) The frequency corresponding to a target at the near limit of the sensing range
20 320 32-bit Integer 100..600 600 Discrete2 PFM Far Frequency (Hz) The frequency corresponding to a target at the far limit of the sensing range

octet 0 1 2 3 4 5 6 7
bit offset 351 - 344 343 - 336 335 - 328 327 - 320 319 - 312 311 - 304 303 - 296 295 - 288
subindex 20 20 20 20 19 19 19 19
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 287 - 280 279 - 272 271 - 264 263 - 256 255 - 248 247 - 240 239 - 232 231 - 224
subindex 18 17 16 15 14 14 14 14
element bit 7 - 0 7 - 0 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 223 - 216 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176 175 - 168 167 - 160
subindex 13 13 13 13 12 11 10 10
element bit 31 - 24 23 - 16 15 - 8 7 - 0 7 - 0 7 - 0 31 - 24 23 - 16

octet 24 25 26 27 28 29 30 31
bit offset 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96
subindex 10 10 9 9 9 9 8 7
element bit 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 7 - 0 7 - 0

octet 32 33 34 35 36 37 38 39
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32
subindex 6 5 4 4 4 4 3 3
element bit 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16

octet 40 41 42 43  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 3 3 2 1  
element bit 15 - 8 7 - 0 7 - 0 7 - 0  

Variable "Port3 Configuration" index=89 id=V_Port3_Configuration

description: Port3 Configuration
data type: 352-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = NPN Input, 1 = PNP Input, 2 = NPN Output with Pull Up, 3 = PNP Output with Pull Down, 4 = NPN Output Push Pull, 5 = PNP Output Push Pull 3 Discrete1 IO Selection
2 8 8-bit UInteger 0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3 = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On One-shot, 8 = Retriggerable Off One-shot 0 Discrete1 Delay Mode Discrete1 Delay Mode Selection
3 16 32-bit Integer 0 Discrete1 Delay Timer 1 Discrete1 On Delay, One-shot, Pulse-stretcher time or Totalizer Count
4 48 32-bit Integer 0 Discrete1 Delay Timer 2 Discrete1 Off Delay or Totalizer time.
5 80 8-bit UInteger 0 = Disabled, 1 = Enabled 0 Discrete1 Mirroring Enable
6 88 8-bit UInteger 0 = Port1, 1 = Port2, 2 = Port3, 3 = Port4, 4 = Port5, 5 = Port6, 6 = Port7, 7 = Port8 0 Discrete1 Mirroring Port Selection
7 96 8-bit UInteger 0 = Discrete1, 1 = Discrete2 0 Discrete1 Mirroring Channel Selection
8 104 8-bit UInteger 0 = Not Inverted, 1 = Inverted 0 Discrete1 Mirroring Inversion
9 112 32-bit Integer 100..600 100 Discrete1 PFM Near Frequency (Hz) The frequency corresponding to a target at the near limit of the sensing range
10 144 32-bit Integer 100..600 600 Discrete1 PFM Far Frequency (Hz) The frequency corresponding to a target at the far limit of the sensing range
11 176 8-bit UInteger 0 = NPN Input, 1 = PNP Input, 2 = NPN Output with Pull Up, 3 = PNP Output with Pull Down, 4 = NPN Output Push Pull, 5 = PNP Output Push Pull 3 Discrete2 IO Selection
12 184 8-bit UInteger 0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3 = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On One-shot, 8 = Retriggerable Off One-shot 0 Discrete2 Delay Mode Discrete2 Delay Mode Selection
13 192 32-bit Integer 0 Discrete2 Delay Timer 1 Discrete2 On Delay, One-shot, Pulse-stretcher time or Totalizer Count
14 224 32-bit Integer 0 Discrete2 Delay Timer 2 Discrete2 Off Delay or Totalizer time
15 256 8-bit UInteger 0 = Disabled, 1 = Enabled 0 Discrete2 Mirroring Enable
16 264 8-bit UInteger 0 = Port1, 1 = Port2, 2 = Port3, 3 = Port4, 4 = Port5, 5 = Port6, 6 = Port7, 7 = Port8 0 Discrete2 Mirroring Port Selection
17 272 8-bit UInteger 0 = Discrete1, 1 = Discrete2 0 Discrete2 Mirroring Channel Selection
18 280 8-bit UInteger 0 = Not Inverted, 1 = Inverted 0 Discrete2 Mirroring Inversion
19 288 32-bit Integer 100..600 100 Discrete2 PFM Near Frequency (Hz) The frequency corresponding to a target at the near limit of the sensing range
20 320 32-bit Integer 100..600 600 Discrete2 PFM Far Frequency (Hz) The frequency corresponding to a target at the far limit of the sensing range

octet 0 1 2 3 4 5 6 7
bit offset 351 - 344 343 - 336 335 - 328 327 - 320 319 - 312 311 - 304 303 - 296 295 - 288
subindex 20 20 20 20 19 19 19 19
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 287 - 280 279 - 272 271 - 264 263 - 256 255 - 248 247 - 240 239 - 232 231 - 224
subindex 18 17 16 15 14 14 14 14
element bit 7 - 0 7 - 0 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 223 - 216 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176 175 - 168 167 - 160
subindex 13 13 13 13 12 11 10 10
element bit 31 - 24 23 - 16 15 - 8 7 - 0 7 - 0 7 - 0 31 - 24 23 - 16

octet 24 25 26 27 28 29 30 31
bit offset 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96
subindex 10 10 9 9 9 9 8 7
element bit 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 7 - 0 7 - 0

octet 32 33 34 35 36 37 38 39
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32
subindex 6 5 4 4 4 4 3 3
element bit 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16

octet 40 41 42 43  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 3 3 2 1  
element bit 15 - 8 7 - 0 7 - 0 7 - 0  

Variable "Port4 Configuration" index=90 id=V_Port4_Configuration

description: Port4 Configuration
data type: 352-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = NPN Input, 1 = PNP Input, 2 = NPN Output with Pull Up, 3 = PNP Output with Pull Down, 4 = NPN Output Push Pull, 5 = PNP Output Push Pull 3 Discrete1 IO Selection
2 8 8-bit UInteger 0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3 = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On One-shot, 8 = Retriggerable Off One-shot 0 Discrete1 Delay Mode Discrete1 Delay Mode Selection
3 16 32-bit Integer 0 Discrete1 Delay Timer 1 Discrete1 On Delay, One-shot, Pulse-stretcher time or Totalizer Count
4 48 32-bit Integer 0 Discrete1 Delay Timer 2 Discrete1 Off Delay or Totalizer time.
5 80 8-bit UInteger 0 = Disabled, 1 = Enabled 0 Discrete1 Mirroring Enable
6 88 8-bit UInteger 0 = Port1, 1 = Port2, 2 = Port3, 3 = Port4, 4 = Port5, 5 = Port6, 6 = Port7, 7 = Port8 0 Discrete1 Mirroring Port Selection
7 96 8-bit UInteger 0 = Discrete1, 1 = Discrete2 0 Discrete1 Mirroring Channel Selection
8 104 8-bit UInteger 0 = Not Inverted, 1 = Inverted 0 Discrete1 Mirroring Inversion
9 112 32-bit Integer 100..600 100 Discrete1 PFM Near Frequency (Hz) The frequency corresponding to a target at the near limit of the sensing range
10 144 32-bit Integer 100..600 600 Discrete1 PFM Far Frequency (Hz) The frequency corresponding to a target at the far limit of the sensing range
11 176 8-bit UInteger 0 = NPN Input, 1 = PNP Input, 2 = NPN Output with Pull Up, 3 = PNP Output with Pull Down, 4 = NPN Output Push Pull, 5 = PNP Output Push Pull 3 Discrete2 IO Selection
12 184 8-bit UInteger 0 = Disabled, 1 = On Off Delay, 2 = On One-shot, 3 = Off One-shot, 4 = On Pulse-stretcher, 5 = Off Pulse-stretcher, 6 = Totalizer, 7 = Retriggerable On One-shot, 8 = Retriggerable Off One-shot 0 Discrete2 Delay Mode Discrete2 Delay Mode Selection
13 192 32-bit Integer 0 Discrete2 Delay Timer 1 Discrete2 On Delay, One-shot, Pulse-stretcher time or Totalizer Count
14 224 32-bit Integer 0 Discrete2 Delay Timer 2 Discrete2 Off Delay or Totalizer time
15 256 8-bit UInteger 0 = Disabled, 1 = Enabled 0 Discrete2 Mirroring Enable
16 264 8-bit UInteger 0 = Port1, 1 = Port2, 2 = Port3, 3 = Port4, 4 = Port5, 5 = Port6, 6 = Port7, 7 = Port8 0 Discrete2 Mirroring Port Selection
17 272 8-bit UInteger 0 = Discrete1, 1 = Discrete2 0 Discrete2 Mirroring Channel Selection
18 280 8-bit UInteger 0 = Not Inverted, 1 = Inverted 0 Discrete2 Mirroring Inversion
19 288 32-bit Integer 100..600 100 Discrete2 PFM Near Frequency (Hz) The frequency corresponding to a target at the near limit of the sensing range
20 320 32-bit Integer 100..600 600 Discrete2 PFM Far Frequency (Hz) The frequency corresponding to a target at the far limit of the sensing range

octet 0 1 2 3 4 5 6 7
bit offset 351 - 344 343 - 336 335 - 328 327 - 320 319 - 312 311 - 304 303 - 296 295 - 288
subindex 20 20 20 20 19 19 19 19
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 287 - 280 279 - 272 271 - 264 263 - 256 255 - 248 247 - 240 239 - 232 231 - 224
subindex 18 17 16 15 14 14 14 14
element bit 7 - 0 7 - 0 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 223 - 216 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176 175 - 168 167 - 160
subindex 13 13 13 13 12 11 10 10
element bit 31 - 24 23 - 16 15 - 8 7 - 0 7 - 0 7 - 0 31 - 24 23 - 16

octet 24 25 26 27 28 29 30 31
bit offset 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96
subindex 10 10 9 9 9 9 8 7
element bit 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 7 - 0 7 - 0

octet 32 33 34 35 36 37 38 39
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32
subindex 6 5 4 4 4 4 3 3
element bit 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16

octet 40 41 42 43  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 3 3 2 1  
element bit 15 - 8 7 - 0 7 - 0 7 - 0  

Variable "MDC Descriptor 5" index=12288 id=V_MDCDescriptor_5

description: Measuring Data Channel Descriptor - refer to Smart Sensor Profile 2nd Ed.
data type: 88-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer MDC Descr - Lower Limit
2 24 32-bit Integer MDC Descr - Upper Limit
3 8 16-bit UInteger 1209 = A, 1240 = V MDC Descr - Unit
4 0 8-bit Integer MDC Descr - Scale

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Variable "MDC Descriptor 6" index=12289 id=V_MDCDescriptor_6

description: Measuring Data Channel Descriptor - refer to Smart Sensor Profile 2nd Ed.
data type: 88-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer MDC Descr - Lower Limit
2 24 32-bit Integer MDC Descr - Upper Limit
3 8 16-bit UInteger 1209 = A, 1240 = V MDC Descr - Unit
4 0 8-bit Integer MDC Descr - Scale

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Variable "MDC Descriptor 7" index=12290 id=V_MDCDescriptor_7

description: Measuring Data Channel Descriptor - refer to Smart Sensor Profile 2nd Ed.
data type: 88-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer MDC Descr - Lower Limit
2 24 32-bit Integer MDC Descr - Upper Limit
3 8 16-bit UInteger 1209 = A, 1240 = V MDC Descr - Unit
4 0 8-bit Integer MDC Descr - Scale

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Variable "MDC Descriptor 8" index=12291 id=V_MDCDescriptor_8

description: Measuring Data Channel Descriptor - refer to Smart Sensor Profile 2nd Ed.
data type: 88-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer MDC Descr - Lower Limit
2 24 32-bit Integer MDC Descr - Upper Limit
3 8 16-bit UInteger 1209 = A, 1240 = V MDC Descr - Unit
4 0 8-bit Integer MDC Descr - Scale

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Variable "Channel 5 Setpoints" index=16400 id=V_SSC5_BDC1_Setpoints

description: The reference value used for sensor switching (See IOL Smart Sensor Profile 9.2.5)
data type: 192-bit Record (subindex access not supported)
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0 Voltage SP1 Voltage SP1 switch point.
2 32 32-bit Integer 10000 Voltage SP2 Voltage SP2 switch point.
3 64 32-bit Integer 50 Voltage Hysteresis The hysteresis value for the Voltage switchpoint.
4 96 32-bit Integer 4000 Current SP1 Current SP1 switch point.
5 128 32-bit Integer 20000 Current SP2 Current SP2 switch point.
6 160 32-bit Integer 100 Current Hysteresis The hysteresis value for the Current switchpoint.

octet 0 1 2 3 4 5 6 7
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 6 6 6 6 5 5 5 5
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 4 4 4 4 3 3 3 3
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 2 2 2 2 1 1 1 1
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Channel 6 Setpoints" index=16401 id=V_SSC6_BDC1_Setpoints

description: The reference value used for sensor switching (See IOL Smart Sensor Profile 9.2.5)
data type: 192-bit Record (subindex access not supported)
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0 Voltage SP1 Voltage SP1 switch point.
2 32 32-bit Integer 10000 Voltage SP2 Voltage SP2 switch point.
3 64 32-bit Integer 50 Voltage Hysteresis The hysteresis value for the Voltage switchpoint.
4 96 32-bit Integer 4000 Current SP1 Current SP1 switch point.
5 128 32-bit Integer 20000 Current SP2 Current SP2 switch point.
6 160 32-bit Integer 100 Current Hysteresis The hysteresis value for the Current switchpoint.

octet 0 1 2 3 4 5 6 7
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 6 6 6 6 5 5 5 5
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 4 4 4 4 3 3 3 3
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 2 2 2 2 1 1 1 1
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Channel 7 Setpoints" index=16402 id=V_SSC7_BDC1_Setpoints

description: The reference value used for sensor switching (See IOL Smart Sensor Profile 9.2.5)
data type: 192-bit Record (subindex access not supported)
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0 Voltage SP1 Voltage SP1 switch point.
2 32 32-bit Integer 10000 Voltage SP2 Voltage SP2 switch point.
3 64 32-bit Integer 50 Voltage Hysteresis The hysteresis value for the Voltage switchpoint.
4 96 32-bit Integer 4000 Current SP1 Current SP1 switch point.
5 128 32-bit Integer 20000 Current SP2 Current SP2 switch point.
6 160 32-bit Integer 100 Current Hysteresis The hysteresis value for the Current switchpoint.

octet 0 1 2 3 4 5 6 7
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 6 6 6 6 5 5 5 5
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 4 4 4 4 3 3 3 3
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 2 2 2 2 1 1 1 1
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Channel 8 Setpoints" index=16403 id=V_SSC8_BDC1_Setpoints

description: The reference value used for sensor switching (See IOL Smart Sensor Profile 9.2.5)
data type: 192-bit Record (subindex access not supported)
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit Integer 0 Voltage SP1 Voltage SP1 switch point.
2 32 32-bit Integer 10000 Voltage SP2 Voltage SP2 switch point.
3 64 32-bit Integer 50 Voltage Hysteresis The hysteresis value for the Voltage switchpoint.
4 96 32-bit Integer 4000 Current SP1 Current SP1 switch point.
5 128 32-bit Integer 20000 Current SP2 Current SP2 switch point.
6 160 32-bit Integer 100 Current Hysteresis The hysteresis value for the Current switchpoint.

octet 0 1 2 3 4 5 6 7
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 6 6 6 6 5 5 5 5
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 4 4 4 4 3 3 3 3
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 2 2 2 2 1 1 1 1
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Events

CodeTypeNameDescription
25376 (0x6320)ErrorParameter errorCheck data sheet and values
36000 (0x8ca0)WarningAll-time Run Time EventEvent indicating the corresponding configured running time has elapsed.
36001 (0x8ca1)WarningResetable Run Time EventEvent indicating the corresponding configured running time has elapsed.

Process Data Formatting

Formatting for Process Data id=PD_ProcessDataIn
Subindex 1:

Formatting for Process Data id=PD_ProcessDataInDMS
Subindex 1:

Formatting for Process Data id=PD_ProcessDataOut
Subindex 1:

Formatting for Process Data id=PD_ProcessDataOutDMS
Subindex 1:

Observer Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_ApplicationSpecificTag

Parameter Menu
V_Vendor_Specific_Configuration.Process Data Input Configuration, ro
V_Vendor_Specific_Configuration.Measurement 1 Metric Selection, ro
V_Vendor_Specific_Configuration.Measurement 1 Port Selection, ro
V_Vendor_Specific_Configuration.Measurement 1 Channel Selection, ro
V_Vendor_Specific_Configuration.Measurement 2 Metric Selection, ro
V_Vendor_Specific_Configuration.Measurement 2 Port Selection, ro
V_Vendor_Specific_Configuration.Measurement 2 Channel Selection, ro
V_Vendor_Specific_Configuration.Measurement 3 Metric Selection, ro
V_Vendor_Specific_Configuration.Measurement 3 Port Selection, ro
V_Vendor_Specific_Configuration.Measurement 3 Channel Selection, ro
V_Vendor_Specific_Configuration.Measurement 4 Metric Selection, ro
V_Vendor_Specific_Configuration.Measurement 4 Port Selection, ro
V_Vendor_Specific_Configuration.Measurement 4 Channel Selection, ro
V_Vendor_Specific_Configuration.POVR1 -Process Data Out 5 Outside Valid Range, ro
V_Vendor_Specific_Configuration.POVR1 -Process Data Out 6 Outside Valid Range, ro
V_Vendor_Specific_Configuration.POVR1 -Process Data Out 7 Outside Valid Range, ro
V_Vendor_Specific_Configuration.Process Data Input Configuration, ro

Observation Menu
V_ProcessDataInput
V_ProcessDataOutput
IO Metrics Ports 1 to 4
V_IO_Metrics_Ports_1_to_4.Port1 Discrete1 Count
V_IO_Metrics_Ports_1_to_4.Port1 Discrete1 Duration µs
V_IO_Metrics_Ports_1_to_4.Port1 Discrete1 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port1 Discrete1 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port1 Discrete2 Count
V_IO_Metrics_Ports_1_to_4.Port1 Discrete2 Duration µs
V_IO_Metrics_Ports_1_to_4.Port1 Discrete2 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port1 Discrete2 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port2 Discrete1 Count
V_IO_Metrics_Ports_1_to_4.Port2 Discrete1 Duration µs
V_IO_Metrics_Ports_1_to_4.Port2 Discrete1 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port2 Discrete1 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port2 Discrete2 Count
V_IO_Metrics_Ports_1_to_4.Port2 Discrete2 Duration µs
V_IO_Metrics_Ports_1_to_4.Port2 Discrete2 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port2 Discrete2 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port3 Discrete1 Count
V_IO_Metrics_Ports_1_to_4.Port3 Discrete1 Duration µs
V_IO_Metrics_Ports_1_to_4.Port3 Discrete1 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port3 Discrete1 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port3 Discrete2 Count
V_IO_Metrics_Ports_1_to_4.Port3 Discrete2 Duration µs
V_IO_Metrics_Ports_1_to_4.Port3 Discrete2 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port3 Discrete2 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port4 Discrete1 Count
V_IO_Metrics_Ports_1_to_4.Port4 Discrete1 Duration µs
V_IO_Metrics_Ports_1_to_4.Port4 Discrete1 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port4 Discrete1 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port4 Discrete2 Count
V_IO_Metrics_Ports_1_to_4.Port4 Discrete2 Duration µs
V_IO_Metrics_Ports_1_to_4.Port4 Discrete2 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port4 Discrete2 Totalizer Counter

Maintenance Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_SerialNumber
V_FirmwareRevision
V_ApplicationSpecificTag

Parameter Menu
Executable Commands
V_SystemCommand, Button:=130
V_SystemCommand, Button:=162
V_SystemCommand, Button:=163
V_SystemCommand, Button:=164
Selectable Metric Reset
V_Selectable_Metric_Reset.Port1 Discrete1
V_Selectable_Metric_Reset.Port1 Discrete2
V_Selectable_Metric_Reset.Port2 Discrete1
V_Selectable_Metric_Reset.Port2 Discrete2
V_Selectable_Metric_Reset.Port3 Discrete1
V_Selectable_Metric_Reset.Port3 Discrete2
V_Selectable_Metric_Reset.Port4 Discrete1
V_Selectable_Metric_Reset.Port4 Discrete2
V_Selectable_Metric_Reset.Port1 Discrete1 Reset Count
V_Selectable_Metric_Reset.Port1 Discrete2 Reset Count
V_Selectable_Metric_Reset.Port2 Discrete1 Reset Count
V_Selectable_Metric_Reset.Port2 Discrete2 Reset Count
V_Selectable_Metric_Reset.Port3 Discrete1 Reset Count
V_Selectable_Metric_Reset.Port3 Discrete2 Reset Count
V_Selectable_Metric_Reset.Port4 Discrete1 Reset Count
V_Selectable_Metric_Reset.Port4 Discrete2 Reset Count
Access Locks
V_DeviceAccessLocks.Local Parameterization Lock
V_DeviceAccessLocks.Local User Interface Lock
Channel 5 Setpoints
V_SSC5_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC5_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC5_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC5_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC5_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC5_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 6 Setpoints
V_SSC6_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC6_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC6_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC6_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC6_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC6_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 7 Setpoints
V_SSC7_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC7_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC7_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC7_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC7_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC7_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 8 Setpoints
V_SSC8_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC8_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC8_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC8_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC8_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC8_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Vendor Specific Configuration
Port1 Configuration
V_Port1_Configuration.Discrete1 IO Selection
V_Port1_Configuration.Discrete1 Delay Mode
V_Port1_Configuration.Discrete1 Delay Timer 1 ms
V_Port1_Configuration.Discrete1 Delay Timer 2 ms
V_Port1_Configuration.Discrete1 Mirroring Enable
V_Port1_Configuration.Discrete1 Mirroring Port Selection
V_Port1_Configuration.Discrete1 Mirroring Channel Selection
V_Port1_Configuration.Discrete1 Mirroring Inversion
V_Port1_Configuration.Discrete1 PFM Near Frequency (Hz)
V_Port1_Configuration.Discrete1 PFM Far Frequency (Hz)
V_Port1_Configuration.Discrete2 IO Selection
V_Port1_Configuration.Discrete2 Delay Mode
V_Port1_Configuration.Discrete2 Delay Timer 1 ms
V_Port1_Configuration.Discrete2 Delay Timer 2 ms
V_Port1_Configuration.Discrete2 Mirroring Enable
V_Port1_Configuration.Discrete2 Mirroring Port Selection
V_Port1_Configuration.Discrete2 Mirroring Channel Selection
V_Port1_Configuration.Discrete2 Mirroring Inversion
V_Port1_Configuration.Discrete2 PFM Near Frequency (Hz)
V_Port1_Configuration.Discrete2 PFM Far Frequency (Hz)
Port2 Configuration
V_Port2_Configuration.Discrete1 IO Selection
V_Port2_Configuration.Discrete1 Delay Mode
V_Port2_Configuration.Discrete1 Delay Timer 1 ms
V_Port2_Configuration.Discrete1 Delay Timer 2 ms
V_Port2_Configuration.Discrete1 Mirroring Enable
V_Port2_Configuration.Discrete1 Mirroring Port Selection
V_Port2_Configuration.Discrete1 Mirroring Channel Selection
V_Port2_Configuration.Discrete1 Mirroring Inversion
V_Port2_Configuration.Discrete1 PFM Near Frequency (Hz)
V_Port2_Configuration.Discrete1 PFM Far Frequency (Hz)
V_Port2_Configuration.Discrete2 IO Selection
V_Port2_Configuration.Discrete2 Delay Mode
V_Port2_Configuration.Discrete2 Delay Timer 1 ms
V_Port2_Configuration.Discrete2 Delay Timer 2 ms
V_Port2_Configuration.Discrete2 Mirroring Enable
V_Port2_Configuration.Discrete2 Mirroring Port Selection
V_Port2_Configuration.Discrete2 Mirroring Channel Selection
V_Port2_Configuration.Discrete2 Mirroring Inversion
V_Port2_Configuration.Discrete2 PFM Near Frequency (Hz)
V_Port2_Configuration.Discrete2 PFM Far Frequency (Hz)
Port3 Configuration
V_Port3_Configuration.Discrete1 IO Selection
V_Port3_Configuration.Discrete1 Delay Mode
V_Port3_Configuration.Discrete1 Delay Timer 1 ms
V_Port3_Configuration.Discrete1 Delay Timer 2 ms
V_Port3_Configuration.Discrete1 Mirroring Enable
V_Port3_Configuration.Discrete1 Mirroring Port Selection
V_Port3_Configuration.Discrete1 Mirroring Channel Selection
V_Port3_Configuration.Discrete1 Mirroring Inversion
V_Port3_Configuration.Discrete1 PFM Near Frequency (Hz)
V_Port3_Configuration.Discrete1 PFM Far Frequency (Hz)
V_Port3_Configuration.Discrete2 IO Selection
V_Port3_Configuration.Discrete2 Delay Mode
V_Port3_Configuration.Discrete2 Delay Timer 1 ms
V_Port3_Configuration.Discrete2 Delay Timer 2 ms
V_Port3_Configuration.Discrete2 Mirroring Enable
V_Port3_Configuration.Discrete2 Mirroring Port Selection
V_Port3_Configuration.Discrete2 Mirroring Channel Selection
V_Port3_Configuration.Discrete2 Mirroring Inversion
V_Port3_Configuration.Discrete2 PFM Near Frequency (Hz)
V_Port3_Configuration.Discrete2 PFM Far Frequency (Hz)
Port4 Configuration
V_Port4_Configuration.Discrete1 IO Selection
V_Port4_Configuration.Discrete1 Delay Mode
V_Port4_Configuration.Discrete1 Delay Timer 1 ms
V_Port4_Configuration.Discrete1 Delay Timer 2 ms
V_Port4_Configuration.Discrete1 Mirroring Enable
V_Port4_Configuration.Discrete1 Mirroring Port Selection
V_Port4_Configuration.Discrete1 Mirroring Channel Selection
V_Port4_Configuration.Discrete1 Mirroring Inversion
V_Port4_Configuration.Discrete1 PFM Near Frequency (Hz)
V_Port4_Configuration.Discrete1 PFM Far Frequency (Hz)
V_Port4_Configuration.Discrete2 IO Selection
V_Port4_Configuration.Discrete2 Delay Mode
V_Port4_Configuration.Discrete2 Delay Timer 1 ms
V_Port4_Configuration.Discrete2 Delay Timer 2 ms
V_Port4_Configuration.Discrete2 Mirroring Enable
V_Port4_Configuration.Discrete2 Mirroring Port Selection
V_Port4_Configuration.Discrete2 Mirroring Channel Selection
V_Port4_Configuration.Discrete2 Mirroring Inversion
V_Port4_Configuration.Discrete2 PFM Near Frequency (Hz)
V_Port4_Configuration.Discrete2 PFM Far Frequency (Hz)
Vendor Specific
V_Vendor_Specific_Configuration.Process Data Input Configuration
V_Vendor_Specific_Configuration.Measurement 1 Metric Selection
V_Vendor_Specific_Configuration.Measurement 1 Port Selection
V_Vendor_Specific_Configuration.Measurement 1 Channel Selection
V_Vendor_Specific_Configuration.Measurement 2 Metric Selection
V_Vendor_Specific_Configuration.Measurement 2 Port Selection
V_Vendor_Specific_Configuration.Measurement 2 Channel Selection
V_Vendor_Specific_Configuration.Measurement 3 Metric Selection
V_Vendor_Specific_Configuration.Measurement 3 Port Selection
V_Vendor_Specific_Configuration.Measurement 3 Channel Selection
V_Vendor_Specific_Configuration.Measurement 4 Metric Selection
V_Vendor_Specific_Configuration.Measurement 4 Port Selection
V_Vendor_Specific_Configuration.Measurement 4 Channel Selection
V_Vendor_Specific_Configuration.POVR1 -Process Data Out 5 Outside Valid Range
V_Vendor_Specific_Configuration.POVR1 -Process Data Out 6 Outside Valid Range
V_Vendor_Specific_Configuration.POVR1 -Process Data Out 7 Outside Valid Range
V_Vendor_Specific_Configuration.POVR1 -Process Data Out 8 Outside Valid Range
V_Vendor_Specific_Configuration.IOL Filter Time
V_Vendor_Specific_Configuration.Port 5 - The Mode of Analog In
V_Vendor_Specific_Configuration.Port 6 - The Mode of Analog In
V_Vendor_Specific_Configuration.Port 7 - The Mode of Analog In
V_Vendor_Specific_Configuration.Port 8 - The Mode of Analog In
V_Vendor_Specific_Configuration.Port 5 - Analog Output Mode
V_Vendor_Specific_Configuration.Port 6 - Analog Output Mode
V_Vendor_Specific_Configuration.Port 7 - Analog Output Mode
V_Vendor_Specific_Configuration.Port 8 - Analog Output Mode
Port 5 Mirroring Configuration
V_Port_Mirroring_Configuration_5
Port 6 Mirroring Configuration
V_Port_Mirroring_Configuration_6
Port 7 Mirroring Configuration
V_Port_Mirroring_Configuration_7
Port 8 Mirroring Configuration
V_Port_Mirroring_Configuration_8

Observation Menu
V_ProcessDataInput
V_ProcessDataOutput
IO Metrics Ports 1 to 4
V_IO_Metrics_Ports_1_to_4.Port1 Discrete1 Count
V_IO_Metrics_Ports_1_to_4.Port1 Discrete1 Duration µs
V_IO_Metrics_Ports_1_to_4.Port1 Discrete1 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port1 Discrete1 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port1 Discrete2 Count
V_IO_Metrics_Ports_1_to_4.Port1 Discrete2 Duration µs
V_IO_Metrics_Ports_1_to_4.Port1 Discrete2 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port1 Discrete2 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port2 Discrete1 Count
V_IO_Metrics_Ports_1_to_4.Port2 Discrete1 Duration µs
V_IO_Metrics_Ports_1_to_4.Port2 Discrete1 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port2 Discrete1 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port2 Discrete2 Count
V_IO_Metrics_Ports_1_to_4.Port2 Discrete2 Duration µs
V_IO_Metrics_Ports_1_to_4.Port2 Discrete2 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port2 Discrete2 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port3 Discrete1 Count
V_IO_Metrics_Ports_1_to_4.Port3 Discrete1 Duration µs
V_IO_Metrics_Ports_1_to_4.Port3 Discrete1 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port3 Discrete1 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port3 Discrete2 Count
V_IO_Metrics_Ports_1_to_4.Port3 Discrete2 Duration µs
V_IO_Metrics_Ports_1_to_4.Port3 Discrete2 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port3 Discrete2 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port4 Discrete1 Count
V_IO_Metrics_Ports_1_to_4.Port4 Discrete1 Duration µs
V_IO_Metrics_Ports_1_to_4.Port4 Discrete1 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port4 Discrete1 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port4 Discrete2 Count
V_IO_Metrics_Ports_1_to_4.Port4 Discrete2 Duration µs
V_IO_Metrics_Ports_1_to_4.Port4 Discrete2 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port4 Discrete2 Totalizer Counter

Diagnosis Menu
Device Status
V_DeviceStatus
V_DetailedDeviceStatus
If V_Vendor_Specific_Configuration.19 = 0:
Measuring Data Channel 5
V_MDCDescriptor_5.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_5.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_5.MDC Descr - Scale
V_MDCDescriptor_5.MDC Descr - Unit
If V_Vendor_Specific_Configuration.19 = 1:
Measuring Data Channel 5
V_MDCDescriptor_5.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_5.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_5.MDC Descr - Scale
V_MDCDescriptor_5.MDC Descr - Unit
If V_Vendor_Specific_Configuration.20 = 0:
Measuring Data Channel 6
V_MDCDescriptor_6.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_6.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_6.MDC Descr - Scale
V_MDCDescriptor_6.MDC Descr - Unit
If V_Vendor_Specific_Configuration.20 = 1:
Measuring Data Channel 6
V_MDCDescriptor_6.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_6.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_6.MDC Descr - Scale
V_MDCDescriptor_6.MDC Descr - Unit
If V_Vendor_Specific_Configuration.20 = 0:
Measuring Data Channel 7
V_MDCDescriptor_7.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_7.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_7.MDC Descr - Scale
V_MDCDescriptor_7.MDC Descr - Unit
If V_Vendor_Specific_Configuration.20 = 1:
Measuring Data Channel 7
V_MDCDescriptor_7.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_7.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_7.MDC Descr - Scale
V_MDCDescriptor_7.MDC Descr - Unit
If V_Vendor_Specific_Configuration.22 = 0:
Measuring Data Channel 8
V_MDCDescriptor_8.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_8.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_8.MDC Descr - Scale
V_MDCDescriptor_8.MDC Descr - Unit
If V_Vendor_Specific_Configuration.22 = 1:
Measuring Data Channel 8
V_MDCDescriptor_8.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_8.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_8.MDC Descr - Scale
V_MDCDescriptor_8.MDC Descr - Unit
Run Counters
V_AllTimeRunTime.Run counter * 0.25 h
V_ResetableRunTime.Run counter * 0.25 h
Event Timers
V_AllTimeRunTimeEventTime.Event Time * 0.25 h
V_ResetableRunTimeEventTime.Event Time * 0.25 h

Specialist Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_SerialNumber
V_FirmwareRevision
V_ApplicationSpecificTag

Parameter Menu
Executable Commands
V_SystemCommand, Button:=130
V_SystemCommand, Button:=162
V_SystemCommand, Button:=163
V_SystemCommand, Button:=164
Selectable Metric Reset
V_Selectable_Metric_Reset.Port1 Discrete1
V_Selectable_Metric_Reset.Port1 Discrete2
V_Selectable_Metric_Reset.Port2 Discrete1
V_Selectable_Metric_Reset.Port2 Discrete2
V_Selectable_Metric_Reset.Port3 Discrete1
V_Selectable_Metric_Reset.Port3 Discrete2
V_Selectable_Metric_Reset.Port4 Discrete1
V_Selectable_Metric_Reset.Port4 Discrete2
V_Selectable_Metric_Reset.Port1 Discrete1 Reset Count
V_Selectable_Metric_Reset.Port1 Discrete2 Reset Count
V_Selectable_Metric_Reset.Port2 Discrete1 Reset Count
V_Selectable_Metric_Reset.Port2 Discrete2 Reset Count
V_Selectable_Metric_Reset.Port3 Discrete1 Reset Count
V_Selectable_Metric_Reset.Port3 Discrete2 Reset Count
V_Selectable_Metric_Reset.Port4 Discrete1 Reset Count
V_Selectable_Metric_Reset.Port4 Discrete2 Reset Count
Access Locks
V_DeviceAccessLocks.Local Parameterization Lock
V_DeviceAccessLocks.Local User Interface Lock
Channel 5 Setpoints
V_SSC5_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC5_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC5_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC5_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC5_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC5_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 6 Setpoints
V_SSC6_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC6_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC6_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC6_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC6_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC6_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 7 Setpoints
V_SSC7_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC7_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC7_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC7_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC7_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC7_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Channel 8 Setpoints
V_SSC8_BDC1_Setpoints.Voltage SP1 * 0.001 V, Dec.3
V_SSC8_BDC1_Setpoints.Voltage SP2 * 0.001 V, Dec.3
V_SSC8_BDC1_Setpoints.Voltage Hysteresis * 0.001 V, Dec.3
V_SSC8_BDC1_Setpoints.Current SP1 * 1E-06 A, Dec.6
V_SSC8_BDC1_Setpoints.Current SP2 * 1E-06 A, Dec.6
V_SSC8_BDC1_Setpoints.Current Hysteresis * 1E-06 A, Dec.6
Vendor Specific Configuration
Port1 Configuration
V_Port1_Configuration.Discrete1 IO Selection
V_Port1_Configuration.Discrete1 Delay Mode
V_Port1_Configuration.Discrete1 Delay Timer 1 ms
V_Port1_Configuration.Discrete1 Delay Timer 2 ms
V_Port1_Configuration.Discrete1 Mirroring Enable
V_Port1_Configuration.Discrete1 Mirroring Port Selection
V_Port1_Configuration.Discrete1 Mirroring Channel Selection
V_Port1_Configuration.Discrete1 Mirroring Inversion
V_Port1_Configuration.Discrete1 PFM Near Frequency (Hz)
V_Port1_Configuration.Discrete1 PFM Far Frequency (Hz)
V_Port1_Configuration.Discrete2 IO Selection
V_Port1_Configuration.Discrete2 Delay Mode
V_Port1_Configuration.Discrete2 Delay Timer 1 ms
V_Port1_Configuration.Discrete2 Delay Timer 2 ms
V_Port1_Configuration.Discrete2 Mirroring Enable
V_Port1_Configuration.Discrete2 Mirroring Port Selection
V_Port1_Configuration.Discrete2 Mirroring Channel Selection
V_Port1_Configuration.Discrete2 Mirroring Inversion
V_Port1_Configuration.Discrete2 PFM Near Frequency (Hz)
V_Port1_Configuration.Discrete2 PFM Far Frequency (Hz)
Port2 Configuration
V_Port2_Configuration.Discrete1 IO Selection
V_Port2_Configuration.Discrete1 Delay Mode
V_Port2_Configuration.Discrete1 Delay Timer 1 ms
V_Port2_Configuration.Discrete1 Delay Timer 2 ms
V_Port2_Configuration.Discrete1 Mirroring Enable
V_Port2_Configuration.Discrete1 Mirroring Port Selection
V_Port2_Configuration.Discrete1 Mirroring Channel Selection
V_Port2_Configuration.Discrete1 Mirroring Inversion
V_Port2_Configuration.Discrete1 PFM Near Frequency (Hz)
V_Port2_Configuration.Discrete1 PFM Far Frequency (Hz)
V_Port2_Configuration.Discrete2 IO Selection
V_Port2_Configuration.Discrete2 Delay Mode
V_Port2_Configuration.Discrete2 Delay Timer 1 ms
V_Port2_Configuration.Discrete2 Delay Timer 2 ms
V_Port2_Configuration.Discrete2 Mirroring Enable
V_Port2_Configuration.Discrete2 Mirroring Port Selection
V_Port2_Configuration.Discrete2 Mirroring Channel Selection
V_Port2_Configuration.Discrete2 Mirroring Inversion
V_Port2_Configuration.Discrete2 PFM Near Frequency (Hz)
V_Port2_Configuration.Discrete2 PFM Far Frequency (Hz)
Port3 Configuration
V_Port3_Configuration.Discrete1 IO Selection
V_Port3_Configuration.Discrete1 Delay Mode
V_Port3_Configuration.Discrete1 Delay Timer 1 ms
V_Port3_Configuration.Discrete1 Delay Timer 2 ms
V_Port3_Configuration.Discrete1 Mirroring Enable
V_Port3_Configuration.Discrete1 Mirroring Port Selection
V_Port3_Configuration.Discrete1 Mirroring Channel Selection
V_Port3_Configuration.Discrete1 Mirroring Inversion
V_Port3_Configuration.Discrete1 PFM Near Frequency (Hz)
V_Port3_Configuration.Discrete1 PFM Far Frequency (Hz)
V_Port3_Configuration.Discrete2 IO Selection
V_Port3_Configuration.Discrete2 Delay Mode
V_Port3_Configuration.Discrete2 Delay Timer 1 ms
V_Port3_Configuration.Discrete2 Delay Timer 2 ms
V_Port3_Configuration.Discrete2 Mirroring Enable
V_Port3_Configuration.Discrete2 Mirroring Port Selection
V_Port3_Configuration.Discrete2 Mirroring Channel Selection
V_Port3_Configuration.Discrete2 Mirroring Inversion
V_Port3_Configuration.Discrete2 PFM Near Frequency (Hz)
V_Port3_Configuration.Discrete2 PFM Far Frequency (Hz)
Port4 Configuration
V_Port4_Configuration.Discrete1 IO Selection
V_Port4_Configuration.Discrete1 Delay Mode
V_Port4_Configuration.Discrete1 Delay Timer 1 ms
V_Port4_Configuration.Discrete1 Delay Timer 2 ms
V_Port4_Configuration.Discrete1 Mirroring Enable
V_Port4_Configuration.Discrete1 Mirroring Port Selection
V_Port4_Configuration.Discrete1 Mirroring Channel Selection
V_Port4_Configuration.Discrete1 Mirroring Inversion
V_Port4_Configuration.Discrete1 PFM Near Frequency (Hz)
V_Port4_Configuration.Discrete1 PFM Far Frequency (Hz)
V_Port4_Configuration.Discrete2 IO Selection
V_Port4_Configuration.Discrete2 Delay Mode
V_Port4_Configuration.Discrete2 Delay Timer 1 ms
V_Port4_Configuration.Discrete2 Delay Timer 2 ms
V_Port4_Configuration.Discrete2 Mirroring Enable
V_Port4_Configuration.Discrete2 Mirroring Port Selection
V_Port4_Configuration.Discrete2 Mirroring Channel Selection
V_Port4_Configuration.Discrete2 Mirroring Inversion
V_Port4_Configuration.Discrete2 PFM Near Frequency (Hz)
V_Port4_Configuration.Discrete2 PFM Far Frequency (Hz)
Vendor Specific
V_Vendor_Specific_Configuration.Process Data Input Configuration
V_Vendor_Specific_Configuration.Measurement 1 Metric Selection
V_Vendor_Specific_Configuration.Measurement 1 Port Selection
V_Vendor_Specific_Configuration.Measurement 1 Channel Selection
V_Vendor_Specific_Configuration.Measurement 2 Metric Selection
V_Vendor_Specific_Configuration.Measurement 2 Port Selection
V_Vendor_Specific_Configuration.Measurement 2 Channel Selection
V_Vendor_Specific_Configuration.Measurement 3 Metric Selection
V_Vendor_Specific_Configuration.Measurement 3 Port Selection
V_Vendor_Specific_Configuration.Measurement 3 Channel Selection
V_Vendor_Specific_Configuration.Measurement 4 Metric Selection
V_Vendor_Specific_Configuration.Measurement 4 Port Selection
V_Vendor_Specific_Configuration.Measurement 4 Channel Selection
V_Vendor_Specific_Configuration.POVR1 -Process Data Out 5 Outside Valid Range
V_Vendor_Specific_Configuration.POVR1 -Process Data Out 6 Outside Valid Range
V_Vendor_Specific_Configuration.POVR1 -Process Data Out 7 Outside Valid Range
V_Vendor_Specific_Configuration.POVR1 -Process Data Out 8 Outside Valid Range
V_Vendor_Specific_Configuration.IOL Filter Time
V_Vendor_Specific_Configuration.Port 5 - The Mode of Analog In
V_Vendor_Specific_Configuration.Port 6 - The Mode of Analog In
V_Vendor_Specific_Configuration.Port 7 - The Mode of Analog In
V_Vendor_Specific_Configuration.Port 8 - The Mode of Analog In
V_Vendor_Specific_Configuration.Port 5 - Analog Output Mode
V_Vendor_Specific_Configuration.Port 6 - Analog Output Mode
V_Vendor_Specific_Configuration.Port 7 - Analog Output Mode
V_Vendor_Specific_Configuration.Port 8 - Analog Output Mode
Port 5 Mirroring Configuration
V_Port_Mirroring_Configuration_5
Port 6 Mirroring Configuration
V_Port_Mirroring_Configuration_6
Port 7 Mirroring Configuration
V_Port_Mirroring_Configuration_7
Port 8 Mirroring Configuration
V_Port_Mirroring_Configuration_8

Observation Menu
V_ProcessDataInput
V_ProcessDataOutput
IO Metrics Ports 1 to 4
V_IO_Metrics_Ports_1_to_4.Port1 Discrete1 Count
V_IO_Metrics_Ports_1_to_4.Port1 Discrete1 Duration µs
V_IO_Metrics_Ports_1_to_4.Port1 Discrete1 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port1 Discrete1 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port1 Discrete2 Count
V_IO_Metrics_Ports_1_to_4.Port1 Discrete2 Duration µs
V_IO_Metrics_Ports_1_to_4.Port1 Discrete2 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port1 Discrete2 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port2 Discrete1 Count
V_IO_Metrics_Ports_1_to_4.Port2 Discrete1 Duration µs
V_IO_Metrics_Ports_1_to_4.Port2 Discrete1 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port2 Discrete1 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port2 Discrete2 Count
V_IO_Metrics_Ports_1_to_4.Port2 Discrete2 Duration µs
V_IO_Metrics_Ports_1_to_4.Port2 Discrete2 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port2 Discrete2 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port3 Discrete1 Count
V_IO_Metrics_Ports_1_to_4.Port3 Discrete1 Duration µs
V_IO_Metrics_Ports_1_to_4.Port3 Discrete1 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port3 Discrete1 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port3 Discrete2 Count
V_IO_Metrics_Ports_1_to_4.Port3 Discrete2 Duration µs
V_IO_Metrics_Ports_1_to_4.Port3 Discrete2 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port3 Discrete2 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port4 Discrete1 Count
V_IO_Metrics_Ports_1_to_4.Port4 Discrete1 Duration µs
V_IO_Metrics_Ports_1_to_4.Port4 Discrete1 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port4 Discrete1 Totalizer Counter
V_IO_Metrics_Ports_1_to_4.Port4 Discrete2 Count
V_IO_Metrics_Ports_1_to_4.Port4 Discrete2 Duration µs
V_IO_Metrics_Ports_1_to_4.Port4 Discrete2 Events Per Minute
V_IO_Metrics_Ports_1_to_4.Port4 Discrete2 Totalizer Counter

Diagnosis Menu
Device Status
V_DeviceStatus
V_DetailedDeviceStatus
If V_Vendor_Specific_Configuration.19 = 0:
Measuring Data Channel 5
V_MDCDescriptor_5.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_5.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_5.MDC Descr - Scale
V_MDCDescriptor_5.MDC Descr - Unit
If V_Vendor_Specific_Configuration.19 = 1:
Measuring Data Channel 5
V_MDCDescriptor_5.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_5.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_5.MDC Descr - Scale
V_MDCDescriptor_5.MDC Descr - Unit
If V_Vendor_Specific_Configuration.20 = 0:
Measuring Data Channel 6
V_MDCDescriptor_6.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_6.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_6.MDC Descr - Scale
V_MDCDescriptor_6.MDC Descr - Unit
If V_Vendor_Specific_Configuration.20 = 1:
Measuring Data Channel 6
V_MDCDescriptor_6.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_6.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_6.MDC Descr - Scale
V_MDCDescriptor_6.MDC Descr - Unit
If V_Vendor_Specific_Configuration.20 = 0:
Measuring Data Channel 7
V_MDCDescriptor_7.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_7.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_7.MDC Descr - Scale
V_MDCDescriptor_7.MDC Descr - Unit
If V_Vendor_Specific_Configuration.20 = 1:
Measuring Data Channel 7
V_MDCDescriptor_7.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_7.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_7.MDC Descr - Scale
V_MDCDescriptor_7.MDC Descr - Unit
If V_Vendor_Specific_Configuration.22 = 0:
Measuring Data Channel 8
V_MDCDescriptor_8.MDC Descr - Lower Limit * 0.001 V, Dec.3
V_MDCDescriptor_8.MDC Descr - Upper Limit * 0.001 V, Dec.3
V_MDCDescriptor_8.MDC Descr - Scale
V_MDCDescriptor_8.MDC Descr - Unit
If V_Vendor_Specific_Configuration.22 = 1:
Measuring Data Channel 8
V_MDCDescriptor_8.MDC Descr - Lower Limit * 1E-06 A, Dec.6
V_MDCDescriptor_8.MDC Descr - Upper Limit * 1E-06 A, Dec.6
V_MDCDescriptor_8.MDC Descr - Scale
V_MDCDescriptor_8.MDC Descr - Unit
Run Counters
V_AllTimeRunTime.Run counter * 0.25 h
V_ResetableRunTime.Run counter * 0.25 h
Event Timers
V_AllTimeRunTimeEventTime.Event Time * 0.25 h
V_ResetableRunTimeEventTime.Event Time * 0.25 h

Note: This page shows the content of an IODD file transformed into HTML format. In the case of disparity between this and the XML view, the content of the XML file takes precedence.
Created by IODD Viewer V1.1.